Simultaneous Measurement of Zinc, Copper, Lead and Cadmium in Baby Weaning Food and Powder Milk by DPASV.

Naficeh Sadeghi, Mohammad Reza Oveisi, Behrooz Jannat, Mannan Hajimahmoodi, Abdolazim Behfar, Masoomeh Behzad, Narges Norouzi, Morvarid Oveisi, Behzad JannatPubMed 2014

TL;DR

This study quantifies essential (zinc, copper) and toxic (lead, cadmium) elements in Iranian baby weaning foods and infant formulas using Differential Pulse Anodic Stripping Voltammetry (DPASV). The findings indicate that while essential elements are generally within acceptable ranges, and toxic metals are below safety limits, specific baby food types show higher zinc levels than labeled, highlighting the need for ongoing quality control in infant nutrition.

What Problem Does This Paper Address?

Infants and young children are particularly vulnerable to the elemental composition of their diet due to their developing systems and limited excretion capabilities. While breast milk is ideal for the first six months, complementary foods and infant formulas become crucial thereafter. Ensuring these foods contain adequate essential nutrients like zinc and copper, while minimizing exposure to toxic heavy metals like lead and cadmium, is paramount for infant health. Previous research has identified variations in these elements across different food products and regions, necessitating localized analysis to inform public health and regulatory efforts. This paper addresses the need for a comprehensive analysis of these critical elements in commonly consumed baby foods and infant formulas within Iran.

Methods

The core analytical technique employed is Differential Pulse Anodic Stripping Voltammetry (DPASV). This electrochemical method is chosen for its ability to simultaneously measure multiple trace elements with high sensitivity and selectivity, and its relatively low cost and speed compared to other techniques.

The process involved:

  • Sample Preparation: A rigorous digestion process was used, involving evaporation to dryness with nitric acid, followed by ashing in a muffle furnace at 450-500°C. The residue was then re-dissolved and diluted to a specific volume.
  • Electrochemical Analysis: A Metrohm Trace Analyzer 746 instrument was used with a three-electrode system: a Hanging Mercury Drop Electrode (HMDE) as the working electrode, a platinum auxiliary electrode, and an Ag/AgCl reference electrode.
  • Quantification: The standard addition technique was utilized. This involves adding known amounts of standard solutions to the sample to create a calibration curve, which helps to overcome potential matrix effects that can interfere with accurate quantification. The concentrations were calculated using linear regression.

Datasets

The study analyzed 240 samples of baby weaning food (120 of Type I - rice and wheat based, and 120 of Type II - rice based) and 240 samples of infant formula (120 of Brand A and 120 of Brand B). These samples were sourced from the market in Tehran, Iran. No new benchmark datasets were introduced; rather, existing commercial products were analyzed.

Key Insights and Ideas

  • DPASV's Utility: The paper reinforces DPASV as a powerful and practical tool for simultaneously analyzing multiple trace elements in complex food matrices, offering advantages in terms of speed, cost, and sensitivity.
  • Vulnerability of Infants: The study underscores the critical importance of monitoring infant food composition due to the heightened susceptibility of infants to both deficiencies and excesses of essential elements, as well as the toxic effects of heavy metals.
  • Regional Variations Matter: By analyzing Iranian products, the study contributes to understanding regional differences in food composition, which can be influenced by local agricultural practices, environmental pollution, and manufacturing processes.
  • Labeling vs. Reality: The finding that one type of baby food (Type I) had significantly higher zinc levels than labeled highlights potential discrepancies between product claims and actual content, emphasizing the need for regulatory oversight.

Key Results

The study found the following mean concentrations (± Standard Error):

Baby Weaning Foods (Total n=240): * Zinc: 11.86 ± 1.474 mg/100g * Copper: 508.197 ± 83.154 µg/100g * Lead: 0.445 ± 0.006 mg/Kg * Cadmium: 0.050 ± 0.005 mg/Kg

Powder Milk (Total n=240): * Zinc: 3.621 ± 0.529 mg/100g * Copper: 403.822 ± 133.953 µg/100g * Lead: 0.007 ± 0.003 mg/Kg * Cadmium: 0.060 ± 0.040 mg/Kg

Specific Findings: * Zinc: Baby food Type I showed significantly higher zinc levels than its labeled value (P = 0.030). Zinc and lead levels in Type I were also higher than in other products. * Copper: All samples had copper concentrations within the labeled ranges (P > 0.05). * Lead and Cadmium: Levels of lead and cadmium in all products were lower than the standard limits (P < 0.05). * Type Comparisons: Zinc and cadmium levels were higher in baby food Type I compared to Type II (P = 0.043 and 0.001, respectively). Lead and cadmium in Type II were higher than in infant formulas but still within standard limits.

Limitations and Future Work

Limitations: * Sample Size: While 240 samples per category were analyzed, the study focused on specific brands and types available in Tehran. A broader geographical scope and a wider range of brands could provide a more comprehensive picture. * Matrix Effects: Although the standard addition method was used to mitigate matrix effects, complex food matrices can still pose challenges for electrochemical analysis. * Variability in Baby Food Types: The paper distinguishes between Type I (rice and wheat) and Type II (rice) baby foods, but further detailed analysis of specific ingredients within these types could offer deeper insights.

Future Work: * Periodic Quality Control: The authors emphasize the need for regular quality control in the preparation of baby food products to ensure consistent and safe elemental profiles. * Broader Analysis: Expanding the analysis to include a wider array of trace elements and heavy metals, as well as a larger number of brands and geographical regions, would be beneficial. * Investigating Sources of Variation: Further research could explore the specific reasons for the higher zinc levels in Type I baby food and the differences observed between baby food types and infant formulas, potentially linking them to agricultural practices, processing methods, or raw material sourcing.

Summary updated

Abstract

Apart from the breast milk, infant formula and baby weaning food have a special role in infant diet. Infants and young children are very susceptible to amount of trace elements. Copper and zinc are two elements that add in infant food. Lead and cadmium are heavy metals that enter to food chain unavoidably. DPASV is a benefit and applicable method for measurement of trace elements in food products. In this study, concentration of zinc, copper, lead and cadmium in four brands of baby food (rice and wheat based) and powder milk was analyzed with DPASV and polarograph set. Total Mean ± SE of zinc, copper, lead and cadmium in baby foods (n = 240) were 11.86 ± 1.474 mg/100g, 508.197 ± 83.154 μg/100g, 0.445 ± 0.006, 0.050 ± 0.005 mg/Kg respectively. Also these amount in powder milk (n = 240) were 3.621± 0.529 mg/100g, 403.822 ± 133.953 μg/100g, 0.007 ± 0.003, 0.060 ± 0.040 mg/Kg respectively. Zinc level in baby food type I was higher than lablled value (P = 0.030), but in other brands was not difference. Concentration of copper in all of samples was in labeled range (P > 0.05). In each four products, level of lead and cadmium were lower than the standard limit (P < 0.05). Amount of zinc and lead in baby food I, had difference versus other products. Concentration of zinc, camium in baby food type I, was higher than type II (P = 0.043, 0.001 respectively). Concentration of lead and cadmium in baby food type II, was higher than infant formulas, but are in standard limit.
BibTeX
@inproceedings{sadeghi2014simultaneous,
  author = {Naficeh Sadeghi and Mohammad Reza Oveisi and Behrooz Jannat and Mannan Hajimahmoodi and Abdolazim Behfar and Masoomeh Behzad and Narges Norouzi and Morvarid Oveisi and Behzad Jannat},
  title = {{Simultaneous Measurement of Zinc, Copper, Lead and Cadmium in Baby Weaning Food and Powder Milk by DPASV.}},
  booktitle = {PubMed},
  year = {2014},
}
Figure