Simultaneous identification and detection of four novel isoxazoline drugs in bovine-origin foods using ultra-high performance liquid chromatography coupled to quadrupole/linear ion trap mass spectrometry

Cheng Yang, Weixia Zhu, Yafeng Liu, Wei Wei, Zhao Fang, Kai Hu, Wenjie ZhaoChinese 2025 · DOI

TL;DR

This paper presents a novel, highly sensitive analytical method for simultaneously detecting and quantifying four new isoxazoline drugs (ISOs) in bovine-origin foods. By combining ultra-high performance liquid chromatography with quadrupole/linear ion trap mass spectrometry (UHPLC-Q/Trap MS) and employing a unique information-dependent acquisition (IDA) strategy with enhanced product ion (EPI) scanning, the method achieves accurate qualitative and quantitative analysis, crucial for ensuring food safety.

What Problem Does This Paper Address?

Isoxazoline drugs (ISOs) are increasingly used to treat parasitic infections in livestock. However, their residues can persist in animal-derived foods, posing potential health risks to humans, including neurotoxicity and hepatotoxicity. While regulatory bodies have set limits for some ISOs in certain animal products, there's a growing need for robust analytical methods to monitor these emerging veterinary drugs, especially in food matrices like milk, beef, and liver, where human consumption is high. Existing methods may lack the sensitivity, specificity, or throughput required for comprehensive monitoring of these novel compounds.

Methods

The core of this study is the development and validation of an analytical method using Ultra-High Performance Liquid Chromatography coupled to Quadrupole/Linear Ion Trap Mass Spectrometry (UHPLC-Q/Trap MS).

Key methodological aspects include:

  • Sample Preparation: A two-step process involving acetonitrile extraction followed by purification using a PRiME HLB solid-phase extraction (SPE) cartridge. This is a standard approach for cleaning up complex food matrices.
  • Chromatographic Separation: A Shim-pack GIST C18-AQ column was used with a gradient elution system employing ammonium acetate and acetonitrile as mobile phases.
  • Mass Spectrometry Detection: The analysis was performed in Multi-Reaction Monitoring (MRM) mode for quantification. Crucially, the method incorporated Information-Dependent Acquisition (IDA) coupled with Enhanced Product Ion (EPI) scanning. This means that when a signal in MRM mode exceeded a certain threshold, the instrument automatically triggered an EPI scan to generate a full fragment ion spectrum.
  • Qualitative Analysis: The EPI spectra were then compared against a spectral library that the researchers built. This dual approach (MRM for quantification and EPI + library search for identification) provides a high degree of confidence in the identification of the ISOs.
  • Quantification: An external standard method was used for quantification.

The novelty lies in the specific combination of UHPLC-Q/Trap MS with the MRM-IDA-EPI strategy for the simultaneous analysis of these four specific ISOs in bovine-origin foods, coupled with the establishment of a dedicated spectral library.

Datasets

The study utilized four novel isoxazoline drugs (fluralaner, sarolaner, afoxolaner, and lotilaner) as analytical standards. These were obtained from TRC (Canada) with a purity of ≥99%.

The food matrices analyzed were:

  • Milk
  • Beef
  • Bovine liver

These samples were purchased from supermarkets in Zhengzhou, China. The researchers also prepared blank matrix extracts from these food types for method optimization and validation.

No new benchmark datasets were introduced; rather, the study focused on developing a method for existing food matrices.

Key Insights and Ideas

  • The Power of Dual Detection (MRM + EPI): The MRM-IDA-EPI approach is a significant advantage. MRM provides high sensitivity and selectivity for quantification, while IDA triggering EPI scans allows for the generation of rich fragmentation data. This "dual qualitative analysis" based on both retention time and EPI fragment ions significantly enhances the accuracy of identification and helps eliminate false positives, which is critical for regulatory purposes.
  • Building a Targeted Spectral Library: The researchers proactively built a spectral library for the target ISOs. This is a key step for reliable qualitative analysis, ensuring that the EPI data can be accurately matched to known compounds.
  • Optimized Sample Preparation is Crucial: The study highlights the importance of optimizing extraction and purification steps. The choice of acetonitrile as the extraction solvent and the PRiME HLB SPE cartridge proved effective in removing matrix interferences, which is a common challenge in analyzing complex food samples.
  • Matrix Effects are Manageable: The study investigated matrix effects in milk, beef, and liver. While some effects were observed (ranging from -18.2% to 18.0%), they were generally within acceptable limits (|ME| ≤ 20%), indicating that the method is robust enough for these matrices without extensive matrix-matched calibration for routine analysis.

Key Results

  • Linearity and Sensitivity: The method demonstrated excellent linearity for all four ISOs within their respective concentration ranges (r ≥ 0.9936). The limits of detection (LODs) were as low as 0.2-0.5 µg/kg, and the limits of quantification (LOQs) were 0.5-1.0 µg/kg, indicating high sensitivity.
  • Recovery and Precision: Recoveries for the four ISOs across low, medium, and high spiked levels (1, 2, and 10 µg/kg) ranged from 67.6% to 118.9%. The relative standard deviations (RSDs) were between 2.0% and 20.0%, demonstrating good accuracy and precision.
  • Qualitative Confirmation: The MRM-IDA-EPI combined with spectral library retrieval achieved high matching scores (98.9% - 99.6%) for spiked samples, confirming the reliability of the qualitative analysis.
  • Method Efficiency: The developed method is described as simple, rapid, and capable of simultaneous qualitative and quantitative analysis of these four novel ISOs in bovine-origin foods.
  • Real Sample Analysis: Analysis of nine commercial samples (beef, milk, and liver) from Zhengzhou found no detectable residues of the four target ISOs.

Limitations and Future Work

  • Limited Scope of Analytes: The method is specifically designed for four novel ISOs. While this is a strength for targeted analysis, future work could expand the method to include a broader range of ISOs or other emerging veterinary drugs.
  • No Residues Detected in Commercial Samples: While the absence of residues in the tested commercial samples is a positive finding for food safety, it also means the method's performance on incurred samples (samples with naturally occurring residues) was not demonstrated.
  • Future Work: The authors suggest that this method can provide technical support for food safety agencies to implement preventive measures against new ISOs in animal foods. This implies a role in regulatory monitoring and risk assessment. Further validation for other food matrices or a wider panel of ISOs would be a logical next step.

Summary updated

Abstract

Isoxazoline drugs (ISOs) are a class of five-membered heterocyclic compounds containing N and O atoms. They can inhibit <i>γ</i>-aminobutyric acid gated chloride channels and are widely used in the treatment of parasitic diseases in poultry. The intake of animal-derived foods by humans is an important way to come into contact with ISOs. Excessive use of ISOs can lead to their residues in animal-derived foods, thereby threatening human health and causing neurotoxicity and hepatotoxicity. To address the safety issues caused by ISO residues in animal-derived foods, an ultra-high performance liquid chromatography-quadrupole/linear ion trap mass spectrometry (UHPLC-Q/Trap MS) analytical method for four novel ISOs (fluralaner, sarolaner, afoxolaner, lotilaner) in bovine-origin foods (including milk, beef and bovine liver) was established. The sample was first extracted with acetonitrile and then purified with PRiME HLB solid phase extraction (SPE) column. Using 5 mmol/L ammonium acetate aqueous solution and acetonitrile as the mobile phase, after separation by Shim-pack GIST C18-AQ (100 mm×2.1 mm, 2.7 μm) chromatography column, the analysis was carried out in the multi-reaction monitoring (MRM) mode by information-dependent acquisition (IDA), enhanced product ion scanning (EPI) and spectral library retrieval, and quantification was performed using the external standard method. The results showed that the four ISOs had good linear relationships within their respective mass concentration ranges. The correlation coefficients (<i>r</i>) were all ≥0.993 6, and the limits of detection (LODs) and quantification (LOQs) were 0.2-0.5 μg/kg and 0.5-1.0 μg/kg, respectively. Under the low, medium and high spiked levels (1, 2 and 10 μg/kg), the recoveries of the four ISOs ranged from 67.6% to 118.9%, and the relative standard deviations (RSDs) ranged from 2.0% to 20.0%. In addition, in this study, qualitative screening and analysis of the target compounds were conducted through MRM-IDA-EPI combined with spectral library retrieval. Dual qualitative analysis of the target compounds was carried out based on information such as retention time and EPI fragment ions, which improved the accuracy of qualitative analysis and effectively eliminated the interference of false positive results. This method features low LODs and good recoveries. It is also simple and rapid to operate, with high sensitivity and accuracy. It can achieve qualitative and quantitative analysis of new ISOs residues in bovine-origin foods. This study can provide technical support for food safety agencies to implement preventive measures against new ISOs in animal foods.
BibTeX
@inproceedings{yang2025simultaneous,
  author = {Cheng Yang and Weixia Zhu and Yafeng Liu and Wei Wei and Zhao Fang and Kai Hu and Wenjie Zhao},
  title = {{Simultaneous identification and detection of four novel isoxazoline drugs in bovine-origin foods using ultra-high performance liquid chromatography coupled to quadrupole/linear ion trap mass spectrometry}},
  booktitle = {Chinese},
  year = {2025},
  doi = {10.3724/sp.j.1123.2024.11012},
}
Figure