Simultaneous determination of six rare sugars in solid foods by high performance liquid chromatography-evaporative light-scattering detection

Yu Liu, Jiali Xing, Jian Shen, Xiaoli Bi, Lingyan Mao, Xiaorong Xu, Shufen Zhang, Yong-Jiang Lou, Xi Wu, Yinghua MuChinese 2023 · DOI

TL;DR

This paper presents a novel, rapid, and sensitive High-Performance Liquid Chromatography-Evaporative Light-Scattering Detection (HPLC-ELSD) method for simultaneously quantifying six rare sugars (allulose, tagatose, trehalose, isomaltulose, erythritol, and mannitol) in solid food products. This method addresses a critical need for accurate food safety monitoring and quality control, as rare sugars gain popularity as sugar substitutes.

What Problem Does This Paper Address?

The increasing consumption of rare sugars as alternatives to traditional sugars, driven by health concerns related to excessive sugar intake, has created a food safety challenge. Issues like false advertising, adulteration, and overdosing of these compounds in food products are on the rise. Currently, there is a lack of a standardized, simultaneous analytical method for determining multiple rare sugars in solid food matrices. This gap hinders effective quality control and consumer protection, necessitating the development of a reliable and efficient analytical technique.

Methods

The researchers developed a method utilizing High-Performance Liquid Chromatography (HPLC) coupled with an Evaporative Light-Scattering Detector (ELSD). The core of the method involves:

  • Chromatographic Separation: A Zorbax Original NH₂ column was used with a gradient elution of acetonitrile and water (80:20 v/v) at a flow rate of 1.0-2.0 mL/min over 25 minutes. This specific column and mobile phase composition were optimized to achieve sharp and well-resolved peaks for all six rare sugars, with resolutions greater than 1.5.
  • ELSD Detection: The ELSD detector's parameters, particularly the nebulizer carrier gas flow rate (1.0 mL/min nitrogen) and drift tube temperature (50°C), were meticulously optimized to maximize sensitivity and signal-to-noise ratio for the rare sugar compounds.
  • Sample Preparation: A simple and efficient sample preparation protocol was established, involving water extraction, followed by purification using zinc acetate and potassium ferricyanide solutions to remove interfering matrix components. This was followed by centrifugation and filtration before injection.
  • Quantification: The external standard method was employed for quantitative analysis, ensuring good linearity (R² > 0.9985) across the tested concentration ranges.

Datasets

The study utilized commercially available rare sugar standards for method development and validation. For sample analysis, various solid food products were purchased, including bread, chocolate, chewing gum, cookies, candy, and lotus root powder. These real-world food samples served as the "dataset" for evaluating the method's applicability. No new benchmark datasets were introduced.

Key Insights and Ideas

  • The Need for Simultaneous Detection: The paper highlights that existing methods often focus on individual rare sugars or require derivatization, making simultaneous analysis of multiple rare sugars in complex matrices challenging. This study directly addresses this by developing a single method for six key rare sugars.
  • ELSD's Suitability: The choice of ELSD is crucial. Unlike UV detectors, ELSD is suitable for compounds lacking chromophores, such as rare sugars. Its compatibility with gradient elution and relative insensitivity to temperature fluctuations (compared to RI detectors) make it ideal for this application.
  • Simple Sample Preparation is Key: The developed method emphasizes a straightforward extraction and purification process, which is vital for routine analysis in food quality control labs. This minimizes sample handling time and potential for errors.
  • Real-World Consistency: The study found that the actual composition of rare sugars in tested food products generally aligned with their labels, suggesting that the developed method can accurately reflect product claims.

Key Results

  • Method Performance: The developed HPLC-ELSD method achieved a simultaneous separation of six rare sugars within 25 minutes.
  • Linearity and Sensitivity: Excellent linearity was observed for all six rare sugars (R² > 0.9985). The method demonstrated good sensitivity with limits of detection (LOD) ranging from 0.020 to 0.60 g/100 g and limits of quantification (LOQ) from 0.60 to 1.8 g/100 g.
  • Accuracy and Precision: Spiked recovery experiments showed high average recoveries (92.6% - 103.2%) and good precision (RSDs of 0.7% - 4.4%), indicating the method's reliability.
  • Interference-Free: Interference studies confirmed that common sugars and artificial sweeteners did not affect the detection of the target rare sugars.
  • Practical Application: The method was successfully applied to analyze actual solid food samples, revealing varying levels of rare sugars, with some products containing up to 29.5 g/100 g.

Limitations and Future Work

  • Potential for Overconsumption: The study notes that some food products contained high levels of rare sugars (over 10%), which could lead to gastrointestinal discomfort. The authors suggest clearer labeling of rare sugar content and potential health effects to consumers.
  • Methodological Standards: While the method is presented as a reliable tool, the paper suggests it can provide technical support for developing future methodological standards and detection limits for rare sugars in Chinese foods.
  • Further Application: The authors imply that this method can be broadly applied for routine monitoring of rare sugars in various food products, contributing to food quality control and safety assessment.

Summary updated

Abstract

Excessive sugar consumption is associated with metabolic health problems. Rare sugars are gradually being used as substitutes for sugar, and their consumption is increasing daily, raising food-safety issues such as false advertising, adulteration, and overdosing. The determination of rare-sugar compounds has attracted considerable attention in recent years. However, no standard method for the simultaneous determination of six rare sugars (allulose, tagatose, trehalose, isomaltulose, erythritol, and mannitol) in solid foods is available. Therefore, establishing a suitable analytical method for these sugars is necessary. In this study, high performance liquid chromatography coupled with evaporative light-scattering detection was used to determine rare sugars in solid foods. The optimum chromatographic and detector conditions were determined by evaluating the instrument parameters. Analysis was carried out on a Zorbax Original NH<sub>2</sub> column (250 mm×4.6 mm, 5 μm) via flow-rate gradient elution (0-15 min, 1.0 mL/min; 15-18 min, 1.0-2.0 mL/min; 18-25 min, 2.0 mL/min) with acetonitrile-water (80∶20, v/v) as the mobile phase. Sharp and symmetric chromatographic peaks were obtained under these conditions. The resolutions for all the six rare sugars were greater than 1.5. Optimization of the evaporative light-scattering detector was extremely important to the responses of the rare-sugar compounds. The two most significant parameters were the nebulizer carrier gas flow rate and drift tube temperature. The detection system was operated under the following conditions: the drift tube temperature was set to 50 ℃, the nebulizer carrier gas was high-purity nitrogen, the carrier gas flow rate was 1.0 mL/min, the nitrogen pressure was regulated to 275.79 kPa, and the gain factor was set to 3. The sample was extracted with 25 mL of water, shaken and vortexed for 10 min, purified with 200 μL of zinc acetate solution and 200 μL of potassium ferricyanide solution, and centrifuged at 4500 r/min for 10 min. Next, 1 mL of the supernatant was passed through a 0.22 μm aqueous-phase filter membrane, and the filtrate obtained was analyzed using the evaporative light-scattering detector. The six rare sugars were quantitatively analyzed using the external standard method and showed good linearity with coefficients of determination (<i>R</i><sup>2</sup>) greater than 0.9985. The limits of detection and quantification were 0.020-0.60 and 0.60-1.8 g/100 g, respectively. In addition, when blank solid food samples were spiked with the analytes at three levels, the average recoveries of the six rare sugars were 92.6%-103.2%, with relative standard deviations (RSDs) of 0.7%-4.4%. An RSD of <5% indicated that the method had good precision. Interference experiments were performed to determine whether the sugars and artificial sweeteners commonly found in solid foods affected the targets. The method established in this study was used to analyze the contents of the six rare sugars in actual solid food samples. The experimental results showed various levels of rare glycoconjugates in different solid foods. Moreover, the actual compositions and labeled of rare glycoconjugates in the solid foods were generally consistent. The proposed method features simple operation, rapid results, high sensitivity, and good reproducibility; thus, it meets the requirements for the detection of the six rare sugars in solid foods. It also provides technical support for the development of methodological standards and detection limits for rare sugars in Chinese foods. The results of this study are of great relevance for the daily monitoring of the levels of the six rare sugars in solid foods.
BibTeX
@inproceedings{liu2023simultaneous,
  author = {Yu Liu and Jiali Xing and Jian Shen and Xiaoli Bi and Lingyan Mao and Xiaorong Xu and Shufen Zhang and Yong-Jiang Lou and Xi Wu and Yinghua Mu},
  title = {{Simultaneous determination of six rare sugars in solid foods by high performance liquid chromatography-evaporative light-scattering detection}},
  booktitle = {Chinese},
  year = {2023},
  doi = {10.3724/sp.j.1123.2023.02014},
}
Figure