Abstract
Devices like the Myo armband available in the market today enable us to collect data about the position of a user's hands and fingers over time. We can use these technologies for sign language translation since each sign is roughly a combination of gestures across time. In this work, we utilize a dataset collected by a group at the University of South Wales, which contains parameters, such as hand position, hand rotation, and finger bend, for 95 unique signs. For each input stream representing a sign, we predict which sign class this stream falls into. We begin by implementing baseline SVM and logistic regression models, which perform reasonably well on high quality data. Lower quality data requires a more sophisticated approach, so we explore different methods in temporal classification, including long short term memory architectures and sequential pattern mining methods.
Introduction
Traditional sign language translation technologies predominantly rely on computer vision. While effective, these systems are constrained by environmental factors such as lighting, background stability, and the requirement for the user to remain within the camera's field of view. This research explores an alternative: wearable sensor-based recognition. By utilizing devices like the Myo armband or specialized gloves, we can capture multi-variate, high-frequency time-series data (hand position, rotation, and finger bend) to classify signs. This approach offers greater mobility and "always-on" utility but introduces the challenge of interpreting complex temporal patterns where the meaning of a gesture is defined by its sequence of movements.
Methods
The study evaluated four primary modeling approaches across two distinct datasets.
Modeling Approaches
- Baselines (SVM & Logistic Regression): Time-series data was "flattened" into single vectors. Both linear and RBF kernels were tested to establish a performance floor.
- Long Short-Term Memory (LSTM): A three-layer Recurrent Neural Network (RNN) architecture was implemented to capture long-term temporal dependencies.
- Sequential Pattern Mining (SPM): Continuous signals were discretized into categorical states (e.g., "high," "low"). An Apriori-based algorithm then identified frequent sequences of these states to serve as sign "fingerprints."
Preprocessing
To ensure consistency across varying capture rates, all data underwent temporal scaling. This involved resampling signals to a standard length using Fast Fourier Transforms (FFT). Additionally, spatial scaling was applied to normalize sensor values between 0 and 1.
Datasets
Two datasets provided by Mohammed Waleed Kadous were used:
- High-Quality Dataset: Recorded at 200 Hz using high-precision "flock gloves" (14-bit orientation) from a single professional signer.
- Low-Quality Dataset: Recorded at 50 Hz using a Nintendo Powerglove. This dataset featured lower precision (2-bit finger bend) and multiple signers, introducing significant noise and variability.
Results
The experimental results highlighted a stark contrast in model performance based on data quality.
On the High-Quality Dataset, simple baseline models were remarkably effective. The SVM achieved a 5.8% test error, suggesting that clean signals may not require complex temporal modeling. Conversely, performance plummeted on the Low-Quality Dataset. The SVM error rose to 45.0%, while more complex models like the LSTM and SPM struggled even more, reaching error rates of 90.8% and 89.5%, respectively.
Ablation studies revealed that wrist position and rotation are the most critical features for recognition. Removing position data caused the error rate to jump from 0.45 to 0.78, whereas individual finger bend data had a comparatively minor impact.
Discussion and Conclusion
The failure of LSTMs on low-quality data was unexpected. The authors hypothesize that standard LSTMs, which backpropagate error at every timestep to predict the next frame, may be ill-suited for whole-gesture classification. A more effective architecture might only backpropagate at the final timestep. Additionally, while SPM showed promise in hybrid models (providing a 1% accuracy boost when combined with SVM features), its computational complexity remains a barrier.
In conclusion, while wearable-based sign language recognition is highly feasible with high-precision sensors, consumer-grade hardware still presents significant challenges. Future work should focus on specialized temporal architectures and more efficient pattern mining to bridge the gap between professional and consumer sensor data.
Summary updated