Sequence and Spatial Feature Fusion for Kidney and Tumor Segmentation From CT Volumes

Han Wenzhong, Kang Li2019

Abstract: Morphological heterogeneity makes the precise segmentation of both the tumor and the kidney becomes a problem for diagnosis and quantitative analysis of the next treatment. In this work, we propose an encoder-decoder architecture which consist of recent neural network for downsampling and 3D convolutional neural network for upsampling. Recent neural network can integrate contextual information between slices and 3D convolutional neural network can make use of spatial information of one case.

1. Introduction

Precise segmentation of kidneys and tumors is critical for pathological staging and radiation planning. However, these structures exhibit significant morphological heterogeneity—they vary wildly in size, shape, and position between patients.

Standard 2D Convolutional Neural Networks (CNNs) process slices independently, losing the rich contextual information available in the "Z-axis" (the sequence of slices). While 3D CNNs can capture spatial volume, they are computationally expensive and can sometimes fail to capture the specific sequential nature of medical imaging data. This paper proposes a hybrid model to bridge this gap by fusing sequence-based memory with volumetric spatial features.

2. Proposed Methodology

The authors propose a U-Net-like architecture that specifically targets the fusion of sequence and spatial data through an asymmetric design.

2.1 The Encoder: Capturing Sequence Context

Each level of the encoder uses a 5x5 2D Convolution followed by a ConvLSTM2D layer. The ConvLSTM acts as a memory mechanism, allowing the network to "remember" and integrate features from adjacent slices as it moves through the CT volume. Instead of just concatenating features, the ConvLSTM layers selectively update internal states, deciding which features from previous slices are relevant to the current one.

2.2 The Decoder: Capturing Spatial Consistency

To reconstruct the segmentation map, the decoder uses 3D Convolutions (3x3x3). This ensures that the final output maintains global spatial consistency across the volume, mitigating the slice-wise artifacts common in purely 2D or sequential approaches.

Proposed hybrid encoder-decoder architecture combining ConvLSTM2D and Conv3D layers.

2.3 Architecture Details

The network follows a multi-level hierarchy where the encoder progressively reduces spatial resolution while increasing feature depth. As detailed in the layer specifications, the encoder utilizes varying max-pooling strides (e.g., (2,2,2) and (1,2,2)) to manage the downsampling of the volumetric sequence. The decoder mirrors this with upsampling and skip connections (concatenation) to preserve high-resolution details for final segmentation.

Detailed layer configuration and output dimensions for the encoding and decoding paths.

3. Training and Preprocessing

The authors employ a two-stage training strategy to handle the scale differences between organs and tumors:

  1. Coarse Stage: The network is trained on resampled, lower-resolution data to locate the kidney.
  2. Fine Stage: The network is trained on original-resolution images to segment small, high-detail tumors, avoiding artifacts caused by resampling.

Preprocessing involves truncating CT intensity values (Hounsfield Units) to a range of [-200, 300] to remove irrelevant tissues (like bone or air) and normalization to improve convergence.

4. Discussion and Conclusion

The core innovation of this work is the asymmetric use of ConvLSTM (2D+sequence) in the encoder and Conv3D (pure spatial) in the decoder. This acknowledges that encoding benefits from "memory" of previous slices, while decoding benefits from "volumetric" smoothing. While quantitative benchmarks against standard 3D U-Nets are not detailed in this summary, the architecture suggests a promising path for volumetric medical tasks where inter-slice continuity is as important as 3D shape.

Summary updated

Abstract

Morphological heterogeneity makes the precise segmentation of both the tumor and the kidney becomes a problem for diagnosis and quantitative analysis of the next treatment. In this work, we propose an encoder-decoder architecture which consist of recent neural network for downsampling and 3D convolutional neural network for upsampling. Recent neural network can integrate contextual information between slices and 3D convolutional neural network can make use of spatial information of one case.
BibTeX
@misc{wenzhong2019sequence,
  author = {Han Wenzhong and Kang Li},
  title = {{Sequence and Spatial Feature Fusion for Kidney and Tumor Segmentation From CT Volumes}},
  year = {2019},
  doi = {10.24926/548719.078},
}
Figure