TL;DR
This paper introduces a novel deep learning (DL) framework for automatically measuring facet joint (FJ) angles from lumbar spine MRIs, enabling large-scale studies of facet tropism (FT). The method demonstrates high accuracy and reliability, comparable to human experts, and reveals the prevalence of FT in a Finnish population, highlighting its potential as a clinical biomarker for low back pain and related disorders.
What Problem Does This Paper Address?
Low back pain (LBP) is a pervasive health issue with complex origins. One proposed contributing factor is facet tropism (FT), which refers to the asymmetry in the orientation of the facet joints in the lumbar spine. FT can alter spinal biomechanics, potentially leading to increased stress on intervertebral discs and contributing to conditions like disc herniation and spinal stenosis. However, accurately measuring FT has been a significant challenge. Traditional methods rely on manual measurement of facet joint angles from medical images, which is time-consuming, labor-intensive, and prone to inter-observer variability. This limits the ability to study FT in large populations and explore its clinical significance as a biomarker for LBP and other spinal disorders. The authors aim to overcome these limitations by developing an automated, deep learning-based approach for FT assessment.
Methods
The core of this research is a deep learning framework designed for the semiautomatic assessment of facet joint angles. The process involves several key steps:
- Segmentation: A UNet++ architecture, a popular encoder-decoder model for medical image segmentation, was employed. This model was trained to identify and segment three crucial regions of interest (ROIs) in axial lumbar spine MRI slices: the vertebral body (VB), the facet joint (FJ), and the posterior arch (PA).
- Landmark Identification: After segmentation, specific anatomical landmarks were identified within these ROIs. These include the anterior and posterior points of the left and right facet joints, the center of the vertebral body, and the spinous process.
- Angle Calculation: Using these identified landmarks, the left (θL) and right (θR) facet joint angles were calculated. Facet tropism (FT) was then defined as the asymmetry between these two angles (θL - θR).
- Model Training: The DL model was trained on a dataset of 430 participants' MRI images. Various training regimens were explored, including using 10%, 50%, and 100% of the data, to assess the impact of data quantity on performance. The model was trained using Adam optimizer with weight decay and employed augmentations like random tone curve, gamma, brightness, contrast, horizontal flip, and Gaussian blur.
- Evaluation Metrics: Model performance was evaluated using standard segmentation metrics like Dice score and Intersection over Union (IoU). Additionally, distance metrics such as Average Surface Distance (ASD) and 95% Hausdorff Distance were used to assess contour accuracy. Inter-rater and intra-rater reliability were assessed using Bland-Altman analysis and correlation coefficients (r²) for both asymmetry and individual facet joint angles.
Datasets
- Northern Finland Birth Cohort 1966 (NFBC1966): This study utilized a retrospective dataset from the NFBC1966 cohort. A total of 12,231 participants born in 1966 were initially identified. For this study, T2-weighted axial lumbar spine MRIs (L3/4 through L5/S1) from 1540 participants (aged 46) were acquired.
- Training and Annotation Data: A subset of 430 participants from the NFBC1966 cohort was used for developing and training the DL model. This subset was further divided for annotations, training, validation, and testing.
- Reliability Data: A subset of 60 participants was randomly selected for inter-rater and intra-rater reliability assessments.
Key Insights and Ideas
- DL for Large-Scale FT Analysis: The most significant insight is the successful development of a DL framework that can automate facet joint angle measurement. This opens the door for large-scale epidemiological studies on FT, which were previously impractical due to manual measurement limitations.
- Comparable to Human Experts: The DL model's performance, particularly in terms of angle measurements and asymmetry, demonstrated high reliability and agreement with human expert raters, suggesting it can serve as a viable alternative.
- Finnish Population FT Prevalence: The study provides the first large-scale data on FT prevalence in a Finnish population, offering valuable demographic-specific insights.
- Potential Biomarker: The findings reinforce the hypothesis that FT could be a significant clinical biomarker for low back pain and related degenerative spinal conditions.
- Data Efficiency: The study showed that even with a relatively small percentage of data (10-50%), the DL model achieved high performance, indicating its potential for efficient training and application.
Key Results
- Segmentation Performance: The DL model achieved high segmentation performance, with Dice scores of 92.7±0.1 and IoU of 87.1±0.2 aggregated across all ROIs (VB, FJ, PA) on the independent test set.
- Angle Measurement Agreement: The mean FJ angles measured by the model for male and female subgroups were in agreement with previous literature findings.
- Inter-Rater Reliability: The study found considerable variability in inter-rater reliability, particularly between radiologists and a musculoskeletal researcher, highlighting the subjective nature of manual annotation. However, the correlation for asymmetry between two radiologists was high (r²=0.84).
- Prevalence of FT: The study found that FT was more prevalent in the male subgroup, with the L4/5 level being the most affected. Using a threshold of >7°, 44.6% of males and 34.9% of females showed FT at L4/5.
- Normal Distribution of Asymmetry: While the overall distribution of facet asymmetry was centered around 1.52°, it did not strictly follow a normal distribution. However, a significant portion of the population (97.07%) had asymmetry within ±20°, and 80.12% within ±10°.
Limitations and Future Work
- Single-Center Data and Annotations: The DL model was trained on data from a single center and primarily annotated by one rater. Future work should incorporate data from multiple centers and account for rater and center variability to enhance generalizability.
- Finnish Population Specificity: The study's demographic is limited to the Finnish population, which may not capture variations in asymmetry related to age, race, or other factors.
- Lack of FJ Disorder Data: The study did not include data on existing FJ disorders (e.g., osteoarthritis), which could act as confounders. Future research should aim to incorporate such clinical data.
- Semiautomatic Framework: The current framework is semiautomatic, requiring manual identification of axial slices per level. Full automation of the method and inclusion of diverse populations are suggested for future work to create a more robust biomarker.
- Clinical Utility Exploration: While the study establishes a method for measuring FT, further research is needed to explore its direct clinical utility as a biomarker for LBP and other spinal disorders.
Summary updated