Self-Calibration Method Based on Surface Micromaching of Light Transceiver Focal Plane for Optical Camera

Jin Li, Yuan Zhang, Si Liu, Zhengjun WangRemote 2016 · DOI

TL;DR

This paper introduces a novel self-calibration method for remote sensing cameras that overcomes temporal and spatial limitations. By integrating a surface micromachined (SM) point-source focal plane with an auto-collimating dichroic filter, the system can autonomously calibrate its inner orientation parameters (IOPs) in real-time, crucial for accurate image positioning in applications like mapping and environmental monitoring.

What Problem Does This Paper Address?

Accurate positioning of images from remote sensing cameras is paramount for applications like mapping, environmental monitoring, and resource exploration. This accuracy hinges on precise knowledge of the camera's inner orientation parameters (IOPs), which describe its internal geometry. Traditional methods for calibrating these IOPs often require external reference targets, controlled laboratory environments, or specific on-orbit maneuvers, leading to limitations in terms of time, space, and operational complexity. The challenge is to develop a method that can reliably and accurately calibrate IOPs without these constraints, enabling real-time, on-orbit calibration.

Methods

The core of the proposed method lies in the integration of two key components:

  • Surface Micromachining (SM) Point-Source Focal Plane (SM-PSFP): This custom-fabricated component integrates point light sources, a beam splitter, and a CMOS sensor. The SM process allows for the precise manufacturing of these elements on a small scale. When activated, the SM-PSFP generates multiple point sources that are used as calibration targets.
  • Auto-Collimating Dichroic Filter (BADF): This specialized filter is designed to selectively transmit and reflect light. It's integrated into the camera's optical path, near the secondary mirror. The BADF acts as a reflective element, directing the light from the SM-PSFP back through the camera's optical system and onto the focal plane. This auto-collimating design ensures that the light path is effectively reversed, allowing the camera to image its own internal calibration sources.

The self-calibration process involves:

  1. Fabrication: Creating the BADF and SM-PSFP.
  2. Integration: Incorporating these components into the camera's optical system.
  3. Mathematical Modeling: Developing a geometric imaging model that relates the positions of the SM point sources to their images on the focal plane, accounting for potential optical system maladjustments.
  4. Calibration: Activating the SM point sources, capturing images with the camera, and using a centroid extraction algorithm to determine the positions of the point source images. These positions are then fed into the mathematical model to calculate the IOPs (principal distance and principal point).

Datasets

Not discussed in the paper. The paper focuses on a novel hardware-based calibration method and its simulation and experimental validation, rather than training on large datasets.

Key Insights and Ideas

  • Integrated Self-Calibration: The most significant insight is the development of a truly integrated self-calibration system. By embedding the calibration source (SM-PSFP) and calibration optics (BADF) directly into the camera, the need for external targets and complex procedures is eliminated.
  • Auto-Collimation for Temporal/Spatial Independence: The use of an auto-collimating light path is ingenious. It allows the camera to calibrate itself without relying on external light sources or specific spatial orientations, making it suitable for both ground and on-orbit applications, regardless of time or location.
  • Surface Micromachining for Precision: Leveraging SM techniques for fabricating the point-source focal plane allows for high precision and miniaturization, which is critical for space-borne applications where size and weight are major constraints.
  • Addressing Optical Maladjustments: The mathematical model is designed to account for potential deviations in the optical system (e.g., due to manufacturing tolerances, temperature changes, or vibration). This makes the calibration robust and applicable even when the camera's optics are not perfectly aligned.

Key Results

The paper presents simulation and experimental results demonstrating the effectiveness of the proposed method:

  • High Accuracy: The method achieves micrometer-level precision in calibration. In simulations, the deviation from the ground method was less than 0.02 µm. In laboratory experiments, the calibration error was less than 2 mm, and the monitoring accuracy reached 0.017 mm for principal distance and 0.005/0.0049 mm for principal point in x/y directions.
  • Reduced Error: Compared to traditional ground calibration methods, the proposed method shows significantly lower errors, especially under simulated maladjustments.
  • Real-time Capability: The system is designed for real-time calibration, allowing for continuous monitoring and adjustment of IOPs.
  • Convenience: The method is described as easy to operate, requiring few auxiliary equipment.

Limitations and Future Work

  • Maladjustment Simulation: While the method accounts for optical maladjustments, the paper primarily relies on simulations and controlled laboratory experiments. The full complexity of on-orbit environmental factors (e.g., extreme temperature variations, radiation) might require further investigation.
  • Accuracy of SM Fabrication: The accuracy of the SM-PSFP fabrication is critical. Any imperfections in the point sources or beam splitters could impact the calibration results.
  • Focusing and Tooling Fixtures: The paper mentions that in laboratory experiments, tooling fixtures did not meet requirements, leading to larger errors. This highlights the importance of precise mechanical integration.
  • Future Work: The authors suggest that the method can be applied to improve the performance of other calibration methods and can be used to verify on-orbit camera functions. Further work could focus on validating the method under more diverse and challenging on-orbit conditions.

Summary updated

Abstract

In remote sensing photogrammetric applications, inner orientation parameter (IOP) calibration of remote sensing camera is a prerequisite for determining image position. However, achieving such a calibration without temporal and spatial limitations remains a crucial but unresolved issue to date. The accuracy of IOP calibration methods of a remote sensing camera determines the performance of image positioning. In this paper, we propose a high-accuracy self-calibration method without temporal and spatial limitations for remote sensing cameras. Our method is based on an auto-collimating dichroic filter combined with a surface micromachining (SM) point-source focal plane. The proposed method can autonomously complete IOP calibration without the need of outside reference targets. The SM procedure is used to manufacture a light transceiver focal plane, which integrates with point sources, a splitter, and a complementary metal oxide semiconductor sensor. A dichroic filter is used to fabricate an auto-collimation light reflection element. The dichroic filter, splitter, and SM point-source focal plane are integrated into a camera to perform an integrated self-calibration. Experimental measurements confirm the effectiveness and convenience of the proposed method. Moreover, the method can achieve micrometer-level precision and can satisfactorily complete real-time calibration without temporal or spatial limitations.
BibTeX
@inproceedings{li2016self,
  author = {Jin Li and Yuan Zhang and Si Liu and Zhengjun Wang},
  title = {{Self-Calibration Method Based on Surface Micromaching of Light Transceiver Focal Plane for Optical Camera}},
  booktitle = {Remote},
  year = {2016},
  doi = {10.3390/rs8110893},
}

Loading related content...

Figure