Selection of Optimal Intensity Measures and Seismic Fragility Analysis of Prefabricated Rectangular Subway Stations

Miao-Jun Qin, Yong Guo, Feng Shi, Yan-Gang Zhao, Xiaobin WangSymmetry 2025

TL;DR

This paper tackles the critical challenge of accurately assessing the seismic risk of prefabricated subway stations by identifying the most effective "intensity measures" (IMs) for predicting their response. They found that the optimal IM depends heavily on how deep the station is buried, leading to a depth-dependent selection strategy that improves seismic fragility analysis for these vital underground structures.

What Problem Does This Paper Address?

Prefabricated subway stations are becoming increasingly common due to their efficiency and sustainability benefits. However, their seismic performance assessment is complex, especially for underground structures which behave differently from above-ground buildings. A key challenge in seismic risk assessment is selecting the right "intensity measure" (IM) – a parameter that quantifies the severity of an earthquake. While peak ground acceleration (PGA) is common for above-ground structures, its suitability for underground systems, particularly subway stations, is debated due to distinct soil-structure interaction effects. Furthermore, the depth at which a subway station is buried significantly influences how it responds to seismic waves. This paper aims to address this by systematically investigating how burial depth affects the choice of optimal IMs for prefabricated rectangular subway stations and developing corresponding seismic fragility curves.

Methods

The researchers employed a comprehensive numerical approach using the ABAQUS finite element software to model a 2D soil-structure interaction (SSI) system. They developed a detailed model of a three-story, two-span prefabricated rectangular subway station, incorporating realistic soil properties and a Concrete Damaged Plasticity Model (CDPM) to simulate material degradation.

Key methodological steps included:

  • Soil-Structure Interaction (SSI) Modeling: A 2D SSI model was constructed, considering the interaction between the soil and the subway station structure. Viscoelastic artificial boundaries (VSAB) were used to simulate a semi-infinite soil medium.
  • Incremental Dynamic Analysis (IDA): This technique was used to subject the model to a range of seismic intensities, allowing for the construction of probabilistic seismic demand models (PSDM).
  • Intensity Measure (IM) Evaluation: A rigorous multi-criteria framework was used to evaluate 19 commonly used IMs. These criteria included:
  • Correlation: How well the IM predicts the damage measure (DM).
  • Efficiency: How well the IM reduces variability in the analysis.
  • Practicality: How sensitive the DM is to changes in the IM (represented by the slope 'b' in regression).
  • Proficiency: An integrated measure balancing practicality and predictive effectiveness.
  • Seismic Fragility Curve Development: Based on the optimal IMs identified for each burial depth, seismic fragility curves were generated. These curves quantify the probability of a structure reaching specific damage states (e.g., minor, moderate, extensive) at different seismic intensities.

Datasets

The study utilized a dataset of 20 real seismic records selected from the Pacific Earthquake Engineering Research (PEER) database. These records were chosen based on magnitudes exceeding 6.0 and epicentral distances ranging from 10 to 300 km, in accordance with Chinese seismic design codes. The input ground motions were scaled to twelve intensity levels, ranging from 0.1 g to 1.2 g, to cover a wide spectrum of seismic severities.

Key Insights and Ideas

  • Burial Depth is Crucial: The most significant finding is that the optimal intensity measure (IM) for seismic analysis of prefabricated subway stations is highly dependent on their burial depth. This challenges the notion of a single "best" IM for all underground structures.
  • Depth-Dependent IM Selection: The study identified distinct optimal IMs for shallow, medium, and deep burial depths, suggesting a need for tailored approaches in seismic risk assessment.
  • Velocity-Related IMs Gain Prominence with Depth: While acceleration-based IMs like PGA are effective for shallow stations, velocity-related IMs (PGV, Urms) become increasingly important and effective for medium and deep-buried stations.
  • Displacement-Related IMs Lag Behind: Displacement-related IMs generally showed weaker correlations and lower predictive capabilities across all burial depths compared to acceleration and velocity-based IMs.
  • Failure Mechanisms are Depth-Influenced: Compressive damage tends to concentrate at the bottom slab for shallow stations, while tensile damage is more prevalent at connection points. As depth increases, the response initially strengthens and then weakens, influencing damage patterns.

Key Results

  • Optimal IMs Identified:
    • Shallow Burial: PGA was found to be the optimal IM, with arms and CAV as viable alternatives.
  • Medium Burial: PGV was identified as the optimal IM, with SED and Urms as strong alternatives.
  • Deep Burial: Urms emerged as the optimal IM, followed closely by PGV and VSI.
  • Correlation Strength Varies: PGA showed the strongest correlation (R²=0.866) for shallow depths, while for deep depths, PGV (R²=0.873) and Urms (R²=0.816) demonstrated robust correlations.
  • Efficiency Varies with Depth: PGA had the lowest logarithmic standard deviation (BD=0.204) for shallow depths, indicating high efficiency. For deep depths, PGV (BD=0.226) and Urms (BD=0.237) showed the best efficiency.
  • Practicality and Proficiency Align with Depth: PGA was most practical for shallow depths, while PGV and Urms showed superior practicality and proficiency for medium and deep depths, respectively.
  • Fragility Curves Developed: Seismic fragility curves were successfully generated for each burial depth, illustrating the probability of different damage states (minor, moderate, extensive) as a function of the optimal IM for that depth.

Limitations and Future Work

  • Limitations:
    • The study focused on 2D modeling, which simplifies the complex 3D behavior of real subway stations.
  • The analysis was conducted for a specific type of prefabricated rectangular subway station and soil conditions. Generalizability to other geometries or soil types may require further investigation.
  • While 20 ground motions were used, a larger ensemble could further enhance the statistical robustness of the results.
  • Future Work:
    • Extend the analysis to 3D models to capture more realistic structural and seismic responses.
  • Investigate the influence of different soil types and geological conditions on IM selection.
  • Explore the seismic performance of other prefabricated subway station typologies.
  • Incorporate more advanced damage models and consider the effects of liquefaction and other site-specific hazards.
  • Further research into the development of performance-based seismic design guidelines specifically for prefabricated underground structures.

Summary updated

BibTeX
@article{qin2025selection,
  author = {Miao-Jun Qin and Yong Guo and Feng Shi and Yan-Gang Zhao and Xiaobin Wang},
  title = {{Selection of Optimal Intensity Measures and Seismic Fragility Analysis of Prefabricated Rectangular Subway Stations}},
  journal = {Symmetry},
  year = {2025},
  doi = {10.3390/sym17040580},
}