Abstract
In this study, an externally reinforced structural system for SMC (Sheet Molding Compound) panel water tanks, designed according to Japanese design codes, was evaluated for seismic performance. A test tank measuring 3m long, 2m wide, and 3m high was subjected to shaking table tests. Experimental results revealed that measured hydrodynamic pressures were approximately 70% of the values predicted by the Japanese design code, likely due to the convex shape effect of the unit panels. Analytical results from an externally reinforced system model showed good agreement with experimental data. This suggests that with proper hydrodynamic pressure estimation, the proposed analytical model is a robust design tool, and current Japanese codes provide a conservative, safe design for SMC panel water tank external frames.
Introduction
Maintaining functional water supplies for firefighting and drinking is a critical post-earthquake requirement. However, regions like Korea often lack specific seismic design standards for modular panel-type water tanks, frequently relying on standards intended for rigid, cylindrical structures. These do not accurately reflect the behavior of flexible, rectangular, externally reinforced tanks. This research evaluates an external reinforcement system designed under the more mature Japanese codes to determine its efficacy in withstanding significant seismic loads, specifically focusing on the hydrodynamic "sloshing" forces exerted against tank walls.
Methodology
The study utilized a dual-track approach combining experimental testing and finite element analysis (FEA).
Shaking Table Experiments
A 3m x 2m x 3m test tank was constructed using SMC panels and an SM490 high-strength steel external frame. The assembly was mounted on a 3-degree-of-freedom shaking table and subjected to artificial seismic waves with a 0.154g base acceleration. Tests were conducted across various scenarios with varying water levels (up to 2.5m) and excitation intensities reaching 200% of the design acceleration.
Analytical Modeling
Finite element modeling was performed using MIDAS software. SMC panels were represented by 4-node plate elements, while the reinforcement frames were modeled as 2-node beam elements. The analysis focused on the distribution of hydrodynamic pressure across the structure, accounting for pressures on both side walls and internal partitions.
Results and Discussion
Hydrodynamic Pressure and the "Convex Effect"
A primary finding was that measured hydrodynamic pressures were significantly lower—approximately 70%—than those predicted by the Japanese design code. This discrepancy is attributed to the convex (curved) geometry of the SMC panels, which appears to dissipate kinetic energy more effectively than flat-walled alternatives.
Structural Integrity and Code Conservatism
The Japanese design code, based on Housner’s rigid-body theory, proved to be conservative. At the design acceleration (0.154g), the maximum measured stress in the reinforcement was 68 MPa, while the analytical model predicted 85 MPa—approximately 25% higher. Even at 200% of the design seismic load, the system maintained structural integrity with no leakage or failure, and stresses remained well below the 190 MPa allowable limit for SM490 steel. The relationship between seismic acceleration and structural stress remained nearly linear, indicating predictable behavior under extreme loads.
Conclusion
The proposed external reinforcement system successfully met safety requirements for design ground accelerations up to 0.4g. While the Japanese code provides a safe design basis, its inherent conservatism suggests opportunities for more economical, optimized structures. Future research should focus on quantifying the pressure-reducing effects of convex panel shapes and developing localized seismic standards that accurately reflect the unique dynamics of modular panel tanks.
Summary updated