TL;DR
This paper presents a novel seismic fragility evaluation for old aqueducts, specifically addressing the often-overlooked leakage risk from water stops during earthquakes. By developing a detailed numerical model that incorporates fluid-structure interaction and probabilistic parameters, the study provides crucial insights into the vulnerability of these critical water infrastructure components.
What Problem Does This Paper Address?
As urban populations grow, the demand for water transportation through aqueducts increases. Many existing aqueducts were built decades ago without modern seismic design considerations, making them potentially vulnerable to earthquakes. A significant concern for these structures is the risk of water leakage from water stops, which can compromise structural integrity and lead to further damage. This paper aims to fill a gap in research by providing a comprehensive seismic fragility assessment of these older aqueducts, specifically focusing on the failure of water stops and their impact on overall safety.
Methods
The study employs a multi-faceted approach to evaluate the seismic fragility of the Hua Shigou aqueduct:
- Numerical Modeling: A two-span model of the aqueduct was created using general finite element software (SAP2000). The superstructure and substructure were modeled as beam elements, and the pile-soil interaction was simplified as a spring element.
- Fluid-Structure Interaction (FSI): The "lumped mass method," based on Housner's theory, was used to simulate the interaction between the water within the aqueduct and the structure. This method accounts for both impulsive and convective water masses.
- Probabilistic Analysis: To account for uncertainties in material properties and environmental factors, the Latin Hypercube Sampling (LHS) method was used to generate multiple sets of input variables. These variables included water weight, concrete strength ($f_c$), and bearing friction coefficient.
- Incremental Dynamic Analysis (IDA): A suite of nine ground motion records was selected and scaled to various intensity levels. IDA was then performed on the numerical models to simulate the aqueduct's response under different earthquake scenarios.
- Damage State Definition: Specific damage states were defined for both the water stop (based on shear deformation and the tangent of the shear angle) and the aqueduct pier (based on drift rate).
- Fragility Curve Development: The results from the IDA were used to develop seismic fragility curves, which represent the probability of exceeding a specific damage state for a given ground motion intensity measure (Peak Ground Acceleration - PGA).
Datasets
- Ground Motion Records: Nine ground motion records were selected from the NGA-West2 On-Line Ground-Motion Database. These records were chosen based on the design response spectrum for the site's seismic fortification intensity and site type (Chinese Code GB_51247-2018).
- Aqueduct Data: Geometric and material properties of the Hua Shigou aqueduct in Ningxia Province, China, were used for the numerical model.
Key Insights and Ideas
- Water Stop Vulnerability: The study highlights that the probability of water stop leakage risk significantly increases with higher ground motion intensity. This underscores the critical need to consider water stop performance in seismic assessments of aqueducts.
- Ductility of Water Stops: Despite their vulnerability, the water stops exhibit good ductility, meaning they can undergo significant deformation before complete failure. This is a positive finding for their seismic performance.
- Pier Dominance in Damage: While water stops are vulnerable, the pier appears to be the more critical component in terms of seismic damage. The fragility curves show a more rapid increase in damage probability for the pier at lower PGA levels compared to the water stop.
- Importance of FSI: The inclusion of fluid-structure interaction is crucial for accurately assessing the seismic response of aqueducts, as the water load significantly influences the structure's behavior.
- Probabilistic Approach: The use of LHS and IDA allows for a robust evaluation of seismic vulnerability by accounting for inherent uncertainties in material properties and ground motion characteristics.
Key Results
- Water Stop Damage Progression: For PGA < 0.5 g, the water stop is likely to be in an intact or slightly damaged state. Between 0.15-0.3 g PGA, it's prone to slight or moderate damage. Complete damage becomes probable when PGA exceeds 0.3 g, with over 50% probability of destruction.
- Pier Damage Progression: For PGA < 0.15 g, the aqueduct pier is likely intact or slightly damaged. In the 0.15-0.2 g PGA range, it's likely to be in a slight or moderate damage state. Complete damage probability exceeds 50% and increases rapidly for PGA > 0.2 g.
- Comparative Vulnerability: Figure 11 visually demonstrates that the pier is generally more vulnerable to seismic damage than the water stop across various PGA levels.
Limitations and Future Work
- Limited Data for Water Stops: The paper acknowledges the lack of extensive damage data for aqueduct water stops, which necessitates subjective definitions of limit states.
- Simplified Pier Model: While the pier's response is modeled, the paper suggests that the effect of height differences between adjacent piers and local damage of prestressed concrete superstructures under fluid-structure coupling should be studied in future work.
- Focus on Transverse Direction: The study primarily focused on the transverse direction of seismic loading, finding it to be more critical. Further investigation into the combined effects of longitudinal and transverse motions could be beneficial.
- Future Research: The authors propose future work to investigate the influence of pier height differences and local damage in prestressed concrete superstructures on seismic vulnerability. They also suggest that the developed analytical model can be broadly applied to the vulnerability analysis of general aqueducts.
Summary updated