Abstract
Accurate segmentation of kidney and renal tumor in CT images is a prerequisite step in surgery planning. However, this task remains a challenge. In this report, we use convolutional networks (ConvNet) to automatically segment kidney and renal tumor. Specifically, we adopt a 2D ConvNet to select a range of slices to be segmented in the inference phase for accelerating segmentation, while a 3D ConvNet is trained to segment regions of interest in the above narrow range. In the localization phase, CT images from several publicly available datasets were used for learning the localizer. This localizer aims to filter out slices impossible to contain kidney and renal tumor, and it was fine-tuned from AlexNet pre-trained on ImageNet. In the segmentation phase, a simple U-net with a large patch size ($160 \times 160 \times 80$) was trained to delineate contours of kidney and renal tumor. In the 2019 MICCAI Kidney Tumor Segmentation (KiTS19) Challenge, 5-fold cross-validation was performed on the training set. 168 (80%) CT scans were used for training and the remaining 42 (20%) cases were used for validation. The resulting average Dice similarity coefficients are 0.9662 and 0.7905 for kidney and renal tumor, respectively.
Introduction
Accurate segmentation of the kidneys and associated tumors is a critical prerequisite for surgical planning in renal cancer treatment. However, automating this process in CT scans is notoriously difficult due to several factors:
- Inhomogeneity: Kidney tissue appearance can vary significantly within a single scan.
- Anatomical Variation: There is high variability in the shape and position of kidneys and tumors between different patients.
- Boundary Ambiguity: Kidneys often share similar intensity values and "blurred" boundaries with adjacent organs like the liver and spleen.
- Computational Efficiency: Processing every single slice of a whole-body CT scan through a complex 3D network is computationally expensive and increases the risk of false positives.
Methods
The proposed framework utilizes a two-stage "Localization + Segmentation" pipeline to address these challenges.
Abdomen Localization
To speed up inference and reduce false positives, a 2D AlexNet (pre-trained on ImageNet) is used for slice-wise classification. Each slice is categorized as "above," "among," or "below" the abdomen. This allows the system to ignore roughly 30% of the scan that definitely does not contain the kidneys.
Kidney and Tumor Segmentation
Once the region of interest is narrowed down, a 3D U-Net is employed. The architecture uses a large patch size ($160 \times 160 \times 80$), replaces standard ReLUs with Leaky ReLUs, and incorporates instance normalization layers. The model was trained using a combination of Dice loss and Cross-Entropy loss to handle class imbalance, as tumors are typically much smaller than the surrounding anatomy.
Results and Discussion
The 5-fold cross-validation on the KiTS19 training set yielded impressive results, with an average Dice similarity coefficient of 0.9662 for kidney segmentation and 0.7905 for tumor segmentation. The localizer successfully filtered out approximately 28% to 32% of non-relevant slices, significantly accelerating the inference phase.
Key insights from the study include:
- Architecture Simplicity: A "simple" 3D U-Net with large patches outperformed more complex variants like NestedV-net or Attention-Gated U-Nets, suggesting that standard architectures can be highly effective when properly optimized.
- Filtering Efficiency: Using a lightweight 2D network to crop the CT volume along the z-axis not only saved computation time but also reduced false positive voxels in non-abdominal regions.
Conclusion
While kidney segmentation has reached near-human levels of accuracy, tumor segmentation remains a significant challenge due to high morphological variety. Future work will focus on developing more discriminative convolutional layers specifically designed to handle the subtle features of renal tumors to close the performance gap between organ and lesion segmentation.
Summary updated