Abstract
Human Activity Recognition (HAR) on wearable devices is often constrained by the "energy wall," where the power demands of deep neural network (DNN) inference or raw data streaming exceed the capacity of small batteries or intermittent energy-harvesting (EH) sources. This paper introduces Seeker, a framework that synergizes mobile and EH wearable sensors to enable robust HAR. By employing "activity-aware coresets" for intelligent data compression and a store-and-execute model for intermittent operation, Seeker achieves high inference accuracy while drastically reducing communication overhead. Experimental results on standard benchmarks show that Seeker attains 86.8% accuracy and an 8.9× reduction in data transmission compared to traditional offloading methods.
Introduction
Wearable technology has evolved to support complex tasks such as continuous health monitoring and Human Activity Recognition (HAR). However, these devices are fundamentally limited by their energy budgets. While on-device DNN execution is computationally intensive, streaming high-frequency sensor data to a host device (like a smartphone) for remote processing is often even more energy-expensive due to the high power cost of wireless communication.
This challenge is exacerbated in Energy Harvesting (EH) systems, where power is scavenged from unreliable environmental sources like solar, thermal, or RF signals. In such intermittent power scenarios, traditional systems often suffer from data loss, leading to significant gaps in activity tracking and reduced inference accuracy. Traditional compression techniques often fail here because low-dimensional sensor data is highly sensitive; losing key data points can cause inference accuracy to plummet.
The Seeker Framework
Seeker addresses these challenges by treating the wearable sensor and the host device as a single, synergistic ecosystem. Unlike conventional approaches that treat sensors as passive data sources, Seeker enables intelligent local processing and adaptive data offloading.
The framework incorporates several key innovations:
- Store-and-Execute Model: Sensors buffer data and perform local inference only when sufficient harvested energy is available. This minimizes unnecessary communication and leverages local compute when power permits.
- Activity-Aware Coresets (AAC): When energy levels are insufficient for full on-device inference, Seeker generates a "coreset"—a small, representative subset of the sensor data that preserves its underlying geometric distribution. The size and composition of the coreset are dynamically adjusted based on the complexity of the activity and the current energy budget.
- Recoverable Coreset Construction: This technique allows the host device to reconstruct a high-fidelity version of the original data from the received coreset. This enables the host to run sophisticated DNNs even when only a fraction of the data is transmitted.
- Data Memoization: Human activities often exhibit temporal continuity (e.g., walking for several minutes). Seeker exploits this by skipping redundant computations if current sensor patterns are highly correlated with recently processed ones.
- Hardware Acceleration: The system is optimized for low-power ReRAM (Resistive RAM) crossbar accelerators, which are well-suited for the intermittent nature of EH-powered computation.
Experimental Evaluation
The performance of Seeker was evaluated using two widely recognized HAR benchmarks: MHEALTH (Mobile Health) and PAMAP2 (Physical Activity Monitoring). These datasets include a variety of physical activities and vital sign recordings from multiple subjects, providing a rigorous testbed for activity recognition algorithms.
Key Results
Seeker demonstrates significant improvements over existing EH-optimized baselines. It achieves a top-1 accuracy of 86.8%, outperforming the state-of-the-art EH-optimized baseline of 81.2%. One of the most impactful results is the 8.9× reduction in transmitted data volume achieved through Activity-Aware Coresets, which directly translates to extended device longevity in energy-constrained environments.
Furthermore, in RF-harvesting scenarios where intermittent power often causes task failure, Seeker successfully completed or offloaded 91.4% of scheduled inferences, compared to only 58.7% for prior methods. The hardware overhead for coreset generation is minimal, with simulations indicating a power consumption of only 130µW.
Conclusion
Seeker represents a significant step toward self-sustaining, high-performance wearable sensing. By moving away from simple data offloading and toward a synergistic model of local intelligence and smart data representation, it overcomes the limitations of intermittent energy harvesting. Future work will focus on physical hardware prototyping and extending the recoverable coreset approach to other time-series sensing domains, such as industrial vibration monitoring and clinical ECG analysis.
Summary updated