Searching for Two-Neutrino and Neutrinoless Double Beta Decay of $^{134}$Xe with the PandaX-4T Experiment

Xiyu Yan, Zhaokan Cheng, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, C. H. Cheng, Xiangyi Cui, Yingjie 英杰 Fan 樊, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Chencheng Han, K. Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, J. Huang, Zhou Huang, Ruquan Hou, Yu Hou, Xiangdong Ji, Yonglin Ju, Chenxiang Li, 李加福 Li Jia-fu, Mingchuan Li, Shuaijie Li, Tao Li, Qing Lin, Jianglai Liu, Xiaoying Lü, Congcong Lu, Lingyin Luo, Yunyang Luo, Wenbo Ma, Yugang Ma, Yajun Mao, Yue Meng, Xuyang Ning, Binyu Pang, Ningchun Qi, Zhicheng Qian, Xiangxiang Ren, Nasir Shaheed, Xiaofeng Shang, Xiyuan Shao, Guofang Shen, Lin Si, Wenliang Sun, Andi Tan, Yi Tao, Anqing Wang, Meng Wang, Qiuhong Wang, Siguang Wang, Wei Wang, Xiuli Wang, Zhou Wang, Yuehuan Wei, Mengmeng Wu, Weihao Wu, Jingkai Xia, Mengjiao Xiao, Xiang Xiao, Pengwei Xie, Binbin Yan, Jijun Yang, Yong Yang, Yukun Yao, Chunxu Yu, Ying Yuan, Zhe Yuan, Xinning Zeng, Dan Zhang, Minzhen Zhang, Peng Zhang, Shibo Zhang, Shu Zhang, Tao Zhang, R. T. Zhang, Yang Zhang, Yingxin Zhang, Yuanyuan Zhang, Li Zhao, Qibin Zheng, Jifang Zhou, N. Zhou, Xiaopeng Zhou, Yong Zhou, Yubo Zhou, Zhou, YuboarXiv 2023 · DOI · arXiv

Abstract

$^{134}$Xe is a candidate isotope for neutrinoless double beta decay ($0\nu\beta\beta$) search. In addition, the two-neutrino case ($2\nu\beta\beta$) allowed by the Standard Model of particle physics has not yet been observed. Utilizing the 10.4% of $^{134}$Xe in the natural xenon in the PandaX-4T detector and its first 94.9-day exposure, we have established the most stringent constraints on $2\nu\beta\beta$ and $0\nu\beta\beta$ of $^{134}$Xe half-lives, with limits of $2.8\times10^{22}$ yr and $3.0\times10^{23}$ yr at 90% confidence level, respectively. The $2\nu\beta\beta$ ($0\nu\beta\beta$) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors.

Introduction

In the Standard Model of particle physics, neutrinos are elusive, nearly massless particles. A major open question is whether neutrinos are Majorana fermions—meaning they are their own antiparticles. If they are, a process called neutrinoless double beta decay ($0\nu\beta\beta$) can occur, where a nucleus decays by emitting two electrons but no neutrinos. Observing this would prove that lepton number is not conserved and help explain the matter-antimatter asymmetry of the universe.

While many experiments focus on $^{136}$Xe, its sibling isotope $^{134}$Xe is also a candidate. However, even the "standard" version of this decay—two-neutrino double beta decay ($2\nu\beta\beta$), which is allowed by the Standard Model—is so rare that it has never been observed in $^{134}$Xe. This paper presents a search for both decay modes using the PandaX-4T detector.

Experimental Methodology

The PandaX-4T experiment, located in the China Jinping Underground Laboratory, utilizes a dual-phase Time Projection Chamber (TPC). A key advantage of this experiment is the use of natural xenon, which contains 10.4% $^{134}$Xe. Most other experiments use xenon enriched with $^{136}$Xe, which inadvertently depletes $^{134}$Xe. PandaX-4T thus provides a much higher ratio of the target isotope relative to backgrounds.

Technical Innovations

To achieve the necessary sensitivity, several technical improvements were implemented:

  • Rolling Gain Calibration: Continuous calibration using single-photon signals from physics data improved the gain accuracy of the photomultiplier tubes (PMTs).
  • Position Reconstruction: A new algorithm based on photon acceptance functions and realistic light-reflection models enhanced event localization within the detector.
  • Signal Discrimination: A dynamic time window was used to separate single-site events (signals) from multi-site gamma-ray backgrounds, accounting for electron diffusion.
Energy resolution of the PandaX-4T detector as a function of energy, with the red star indicating the resolution at the $^{134}$Xe Q-value.

As shown in Figure 1, the detector achieved an energy resolution of 2.4% at the $^{134}$Xe Q-value (825.8 keV), which is critical for distinguishing potential signals from background noise.

Data Analysis and Results

The analysis focused on 94.9 live days of data from a central 656-kg fiducial volume of natural xenon. Backgrounds, primarily from isotopes like $^{212}$Pb, $^{85}$Kr, and $^{222}$Rn, were modeled using the BambooMC framework. By extending the analysis threshold down to 200 keV, the team captured a larger portion of the $2\nu\beta\beta$ energy spectrum.

Energy spectrum fit of single-site events in the 200–1000 keV range, showing various background components and the hypothetical $0\nu\beta\beta$ signal.

The energy spectrum fit (Figure 4) showed no significant excess of events over the expected background. This led to new world-leading lower limits on the half-lives at a 90% confidence level:

  • $2\nu\beta\beta$ Half-life: $> 2.8 \times 10^{22}$ years (a 32-fold improvement over previous results).
  • $0\nu\beta\beta$ Half-life: $> 3.0 \times 10^{23}$ years (a 2.7-fold improvement).

The study noted that systematic uncertainties, particularly from background constraints, are currently the dominant factor limiting sensitivity.

Conclusion

PandaX-4T has established the most stringent constraints to date on the double beta decay of $^{134}$Xe. These results highlight the potential of large monolithic natural xenon detectors. Future work will focus on reducing internal backgrounds and accumulating more exposure time, potentially leading to the first-ever observation of $2\nu\beta\beta$ in $^{134}$Xe.

Summary updated

Abstract

$^{134}$Xe is a candidate isotope for neutrinoless double beta decay~($0νββ$) search. In addition, the two-neutrino case ($2νββ$) allowed by the Standard Model of particle physics has not yet been observed. Utilizing the 10.4% of $^{134}$Xe in the natural xenon in the PandaX-4T detector and its first 94.9-day exposure, we have established the most stringent constraints on $2νββ$ and $0νββ$ of $^{134}$Xe half-lives, with limits of $2.8\times10^{22}$ yr and $3.0\times10^{23}$ yr at 90% confidence level, respectively. The $2νββ$ ($0νββ$) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors.
BibTeX
@misc{yan2023searching,
  author = {Xiyu Yan and Zhaokan Cheng and Abdusalam Abdukerim and Zihao Bo and Wei Chen and Xun Chen and C. H. Cheng and Xiangyi Cui and Yingjie 英杰 Fan 樊 and Deqing Fang and Changbo Fu and Mengting Fu and Lisheng Geng and Karl Giboni and Linhui Gu and Xuyuan Guo and Chencheng Han and K. Han and Changda He and Jinrong He and Di Huang and Yanlin Huang and J. Huang and Zhou Huang and Ruquan Hou and Yu Hou and Xiangdong Ji and Yonglin Ju and Chenxiang Li and 李加福 LI Jia-fu and Mingchuan Li and Shuaijie Li and Tao Li and Qing Lin and Jianglai Liu and Xiaoying Lü and Congcong Lu and Lingyin Luo and Yunyang Luo and Wenbo Ma and Yugang Ma and Yajun Mao and Yue Meng and Xuyang Ning and Binyu Pang and Ningchun Qi and Zhicheng Qian and Xiangxiang Ren and Nasir Shaheed and Xiaofeng Shang and Xiyuan Shao and Guofang Shen and Lin Si and Wenliang Sun and Andi Tan and Yi Tao and Anqing Wang and Meng Wang and Qiuhong Wang and Qiuhong Wang and Siguang Wang and Wei Wang and Xiuli Wang and Zhou Wang and Yuehuan Wei and Mengmeng Wu and Weihao Wu and Jingkai Xia and Mengjiao Xiao and Xiang Xiao and Pengwei Xie and Binbin Yan and Jijun Yang and Yong Yang and Yukun Yao and Chunxu Yu and Ying Yuan and Zhe Yuan and Xinning Zeng and Dan Zhang and Minzhen Zhang and Peng Zhang and Shibo Zhang and Shu Zhang and Tao Zhang and R. T. Zhang and Yang Zhang and Yingxin Zhang and Yuanyuan Zhang and Li Zhao and Qibin Zheng and Jifang Zhou and N. Zhou and Xiaopeng Zhou and Yong Zhou and Yubo Zhou and Zhou, Yubo},
  title = {{Searching for Two-Neutrino and Neutrinoless Double Beta Decay of $^\{134\}$Xe with the PandaX-4T Experiment}},
  year = {2023},
  eprint = {2312.15632},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2312.15632},
}
Figure