<scp>Diffusion‐weighted double‐echo steady‐state</scp> with a <scp>three‐dimensional</scp> cones trajectory for <scp>non‐contrast‐enhanced</scp> breast <scp>MRI</scp>

Catherine J. Moran, Joseph Y. Cheng, Christopher M. Sandino, Michael Carl, Marcus T. Alley, Jarrett Rosenberg, Bruce L. Daniel, Sarah M Pittman, Eric L. Rosen, Brian A. HargreavesJournal of Magnetic Resonance Imaging 2020

Abstract

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.
BibTeX
@article{moran2020scp,
  author = {Catherine J. Moran and Joseph Y. Cheng and Christopher M. Sandino and Michael Carl and Marcus T. Alley and Jarrett Rosenberg and Bruce L. Daniel and Sarah M Pittman and Eric L. Rosen and Brian A. Hargreaves},
  title = {{<scp>Diffusion‐weighted double‐echo steady‐state</scp> with a <scp>three‐dimensional</scp> cones trajectory for <scp>non‐contrast‐enhanced</scp> breast <scp>MRI</scp>}},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2020},
  doi = {10.1002/jmri.27492},
}

Loading related content...

Figure