Scoliosis5K: Multimodal Gait Analysis via Clip-Conditioned RGB-Silhouette Fusion

Zizhao Peng, Zihan Wang, Zheng Lv, Yan Wang, Ping Li, Fengwei AnarXiv 2026

Late at night, after the world has quieted down, it’s easy to forget how much information is hidden in the simple act of walking. For most of us, a stroll is just a way to get from A to B. But for a clinician, your gait is a complex signature of your health. This paper introduces Scoliosis5K, a massive new effort to use AI to read that signature and screen for scoliosis—a sideways curvature of the spine—simply by watching people walk down a hallway.

TL;DR

By combining "ghostly" binary silhouettes with full-color video, researchers have built a multimodal AI system that can spot scoliosis-related gait patterns with over 83% accuracy. The study reveals a fascinating "multimodal paradox": while adding silhouettes doesn't drastically change the total accuracy, it completely reshapes which patients the AI identifies, proving that outlines and color video see the body in fundamentally different ways.

What Problem Does This Paper Address?

Scoliosis screening is traditionally a manual, sometimes radiation-heavy (X-ray) process. Computer vision offers a non-invasive alternative, but it has been stuck in a data desert.

Existing gait datasets usually provide either binary silhouettes (think of a black-and-white cutout of a person) or 2D "skeletons." While silhouettes are great for capturing the geometry of a stride, they throw away crucial details like clothing dynamics, surface appearance, and environmental context. To truly understand what each "view" contributes to a diagnosis, you need a dataset where color video and silhouettes are perfectly synchronized. Until now, that didn't exist for scoliosis at scale.

Methods

The authors developed a sophisticated "two-branch" architecture to process these different types of data:

  1. The RGB Branch: They took a powerful pretrained image model (DINOv2) and "conditioned" it on motion. Instead of a full retraining, they used a clever trick called Patch-Conditioned Adaptation. By measuring how much pixels in a specific patch deviate from their average over time, the model creates a "gate" that tunes itself to the dynamics of the walk.
  2. The Silhouette Branch: This uses a "divided space-time transformer" to analyze the 2D outlines. Interestingly, during training, this branch is "supervised" by the RGB branch—essentially, the silhouette model tries to learn features that mimic the rich information found in the color video.
  3. Regional RGB Branch: Because video crops are often low-resolution, a separate branch looks at high-resolution "native" frames, dividing the person into a grid to catch fine-grained details that the video might miss.
Fig. 2. Overview of paired RGB and silhouette gait classification. (a) Slots 1, 12, and 24 from one training walk sampled every second frame; RGB thumbnails retain native crop aspect ratios with head masking and block averaging for display, while the silhouette strip map plots mean absolute frame-to-frame change across 16 height bands (the encoder receives the binary masks directly). Stream-specific learned queries pool valid tokens, a training-only predictor aligns the pooled silhouette vector with the centered frozen RGB target, and the classifier concatenates both projected streams to output window logits dw. (b) Patch-deviation gate map and temporal traces computed on the model RGB inputs prior to display masking across the 24 slots; each patch gate gtr mixes two rank-two updates in every query and value projection while key projections remain fixed. (c) Native-frame regional kernel ridge regression (KRR) compares eight central grid cells from slot 12 against training participants, producing scores sw scaled by t and fused with dw across 20 windows per participant.

Datasets

The star of the show is Scoliosis5K.

  • Scale: 4,998 walking sequences from 3,010 participants across nine different clinical sites.
  • Modalities: Every frame is a "triple threat," containing an RGB crop, a binary silhouette, and 17 2D pose landmarks (see Figure 1).
  • Labels: Participants are categorized as Negative, Neutral, or Positive for scoliosis-related gait patterns.
Fig. 1. Synchronized modalities from two frames (t and t + 6) of three training participants across forward, left, and backward walking views. Zero-based frame indices appear at left. RGB crops (Xw) are block-averaged and masked through the shoulders for display; at right, 17 stored ViTPose landmarks (indices 0–16 of the 25-keypoint COCO-25 layout, extending through the knees; solid lines with filled markers denote subject left, dashed lines with open markers denote subject right) overlay the paired 64 × 64 silhouette (Sw).

Key Insights and Ideas

  • The Silhouette Paradox: The most surprising finding was what happened when the researchers "zeroed out" the silhouette data. The overall accuracy barely budged (dropping only 0.10%). However, the recall for the "Positive" category jumped by over 9 percentage points. This means that while silhouettes help the model's general understanding, they might actually make it too conservative when identifying actual cases of scoliosis.
  • Motion as a Gating Signal: Using pixel deviation as a zero-parameter gate is a brilliant, efficient way to turn an "image" model into a "video" model without the computational nightmare of a full-scale video transformer.
  • Site-Invariant Learning: By testing across nine different sites, the authors ensured the model wasn't just "learning the hallway" of a specific hospital, but actually identifying human movement patterns.

Key Results

  • Top Performance: The complete multimodal system achieved 83.77% accuracy and a macro-averaged AUROC of 0.950.
  • Comparison: This outperformed silhouette-only baselines (like GaitSet or GaitGL) and standard RGB-only video models.
  • Efficiency: The model achieves these results with a relatively small number of trainable parameters (about 73,000 for the adapter), making it a candidate for parameter-efficient fine-tuning.
Fig. 3. Silhouette-removal intervention and multi-window scaling on the 988 held-out participants. (a) Class-specific recall with the silhouette vector retained or zeroed prior to shared layer normalization (regional RGB scores active in both conditions; recall differences are computed before rounding, in percentage points). (b) Mean participant accuracy across three seeds and 500 random permutations of k ∈{1, 2, 5, 10, 20} evaluation windows per participant (all models share identical sampled windows per draw; vertical bars span the 2.5th to 97.5th percentiles of the full model across draws, with k = 20 using the full bank).

Limitations and Future Work

While Scoliosis5K is a massive leap forward, the authors note a few hurdles:

  • Missing "Gold Standard": The dataset currently lacks "Cobb angles"—the precise degree of spinal curvature measured from X-rays. Future versions will need to link gait scores directly to these clinical measurements.
  • Privacy: The study uses head masking for privacy, but the authors suggest that training models directly on privacy-preserved data (rather than masking it after the fact) is a vital next step for real-world clinical deployment.
  • Generalization: While multi-site, the model still needs to be "stress-tested" on entirely new clinical centers it has never seen before.

Summary updated

Abstract

Color walking video records body boundary motion alongside clothing folds, surface appearance, and recording-environment cues. To examine what an explicit binary silhouette contributes to participant-level classification of scoliosis-related gait when a classifier already observes the paired color sequence, we construct Scoliosis5K, a multi-site collection of 4,998 corridor-walking sequences across 3,010 participant identifiers in which RGB person crops, binary silhouettes, and two-dimensional poses share each recording identifier and frame index. Our architecture uses each patch's pixel deviation from its clip mean to weight two low-rank query and value updates inside a pretrained RGB encoder, fusing the resulting video representation with a silhouette transformer sequence and regional kernel ridge scores extracted from one native-resolution RGB frame per window. Across 988 participants in five participant-disjoint cross-validation folds and three training seeds, the complete system reaches 83.77% accuracy and 79.91% macro-averaged F1, compared with 83.27% accuracy and 79.56% macro-F1 when the video RGB encoder remains frozen under identical inputs. Zeroing the silhouette vector at fixed weights shifts overall accuracy by only 0.10 percentage points while raising positive-category recall from 68.52% to 77.78% and lowering recall for both remaining categories. Macro-averaged AUROC is 0.950 across the cohort and 0.879 among participant pairs matched on acquisition site and recording-count group.
BibTeX
@misc{peng2026scoliosis,
  author = {Zizhao Peng and Zihan Wang and Zheng Lv and Yan Wang and Ping Li and Fengwei An},
  title = {{Scoliosis5K: Multimodal Gait Analysis via Clip-Conditioned RGB-Silhouette Fusion}},
  year = {2026},
  eprint = {2611.26849},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.26849},
}
Figure