TL;DR
This paper details the performance of the photon detection system (PDS) in ProtoDUNE-DP, a large-scale liquid argon time-projection chamber (LArTPC) prototype for the DUNE experiment. It evaluates the effectiveness of different wavelength shifters (PEN and TPB) and Xe-doping in liquid argon for detecting scintillation light, crucial for triggering and precise timing in future neutrino detectors.
What Problem Does This Paper Address?
The DUNE experiment aims to unravel fundamental mysteries in neutrino physics, requiring highly sensitive detectors capable of precisely measuring neutrino interactions. Liquid argon time-projection chambers (LArTPCs) are a key technology for DUNE, but detecting the faint scintillation light produced by charged particles over large volumes (up to 6 meters drift length) presents a significant challenge. This light is essential for triggering on rare events, determining precise event times, and improving energy measurements. The ProtoDUNE-DP experiment was designed to test and validate the performance of a large-scale LArTPC, specifically focusing on its photon detection system's ability to collect this crucial scintillation light efficiently and reliably across its entire volume.
Methods
The ProtoDUNE-DP detector utilized a Photon Detection System (PDS) composed of 36 cryogenic photomultiplier tubes (PMTs). To make the vacuum ultraviolet (VUV) scintillation light (around 127 nm) visible to the PMTs, wavelength shifters were employed. Two types were tested: polyethylene naphthalate (PEN) foils and tetraphenyl butadiene (TPB) directly coated onto the PMTs. The study also investigated the impact of doping the liquid argon with Xenon (Xe) and Nitrogen (N2) on light production and propagation. Data analysis involved comparing collected signals with simulations generated using the LArSoft package, which incorporates Geant4 for detector geometry and CORSIKA for cosmic ray simulations. Various trigger modes (PMT self-trigger, CRT trigger, calibration mode) were used to collect data.
Datasets
The paper analyzes data collected by the ProtoDUNE-DP detector at CERN between June 2019 and November 2020. This dataset includes cosmic muon data taken under various conditions, including pure liquid argon, Xe-doped liquid argon, and liquid argon with different concentrations of N2. The data was collected using different trigger modes, and a significant number of events (over 130 million) were analyzed.
Key Insights and Ideas
- TPB Outperforms PEN for Light Collection: While PEN offers simpler installation, TPB-coated PMTs were found to be significantly more efficient at collecting scintillation light, making TPB the preferred choice for future DUNE detectors where maximizing light yield is critical.
- Xe Doping Enhances Light Detection: Doping liquid argon with Xenon (Xe) significantly improves light detection efficiency and uniformity, especially for signals originating far from the PMTs. This is attributed to Xe's ability to shift scintillation light to longer wavelengths with a longer Rayleigh scattering length.
- N2 Impurities are Detrimental: Nitrogen (N2) impurities in liquid argon lead to a reduction in scintillation light yield due to quenching processes, negatively impacting detector performance.
- Drift Field Suppresses Recombination Light: The electric drift field in the LArTPC suppresses light produced by electron-ion recombination, which is a significant component of the primary scintillation signal in the absence of a field.
- Large-Scale LArTPCs are Feasible: The successful operation of ProtoDUNE-DP, with its 6-meter drift length, demonstrates the feasibility of building and operating large-scale LArTPCs for future neutrino experiments.
Key Results
- TPB vs. PEN Efficiency: TPB-coated PMTs detect approximately three times more visible photons than PEN-foil PMTs for the same amount of incident VUV photons (EPEN/ETPB = 0.35 ± 0.09).
- Light Yield: The PDS detects about 2.3 PE/MeV for random-trigger events and 0.7 PE/MeV for CRT-triggered muon tracks.
- Drift Field Effect: At a cathode voltage of -50 kV, the detected light was reduced by approximately 17% compared to the no-drift-field case, indicating the suppression of recombination light.
- Attenuation Length: The data is better described by a Rayleigh scattering length (RSL) of 99.9 cm than 61.0 cm.
- Xe Doping Impact: Xe doping increased the collected light by up to 100% for muons at distances of 3-5 meters from the PMTs.
- Cosmic Muon Flux: The measured cosmic muon flux at CERN was determined to be 148 ± 11 Hz/m².
Limitations and Future Work
- HV Issues: The ProtoDUNE-DP operation was impacted by a short circuit in the high-voltage system, preventing the achievement of nominal cathode voltages. This limited the study of the drift field's full effect.
- CRP Operation: Bubbles on the liquid argon surface caused issues with the charge readout planes (CRPs), limiting the combined operation of CRPs and the PDS.
- Backgrounds: The presence of background signals, particularly from natural radioactivity and cosmic muons, can affect the detection of low-energy signals and requires careful analysis.
- Future Work: The paper suggests that the successful operation of ProtoDUNE-DP validates the PDS design for future large-scale LArTPCs. Further studies could explore the impact of different Xe and N2 concentrations on light production and propagation, and refine the understanding of photon interactions in liquid argon. The potential of PEN as a wavelength shifter for applications where detection efficiency is less critical is also noted.
Summary updated