Role of Corneal Elasticity in Damping of Intraocular Pressure

C. Starck Johnson, Shahzad I. Mian, Sayoko E. Moroi, David L. Epstein, Joseph A. Izatt, Natalie A. AfshariInvestigative 2007 · DOI

TL;DR

This study investigates the mechanical properties of the cornea, demonstrating its elasticity and ability to expand and thin under increased pressure. These findings suggest the cornea acts as a crucial buffer against sudden intraocular pressure spikes, potentially offering protection against conditions like glaucoma.

What Problem Does This Paper Address?

The paper addresses a long-standing question about the cornea's role in the overall elasticity of the eye. While early studies established that the eye as a whole is distensible, the specific contribution of the cornea was often underestimated, with a perception of it being a relatively inelastic structure. This lack of understanding limits our ability to fully grasp how the eye copes with rapid changes in intraocular pressure (IOP), which is critical for understanding conditions like glaucoma. The authors aim to isolate and quantify the corneal contribution to this pressure-damping mechanism.

Methods

The researchers used human donor corneas, excised with a small scleral rim, and mounted them in an artificial anterior chamber. A watertight seal was achieved in most specimens. Saline was infused into the chamber at a controlled rate (10 mL/h), and the resulting pressure changes were meticulously recorded. To dynamically measure the cornea's response, a time-domain optical coherence tomography (OCT) system was employed in a subset of experiments. This allowed for real-time measurement of changes in the corneal radius of curvature. In a few cases, the OCT system was also capable of measuring changes in corneal thickness. Control experiments were performed without the corneal-scleral shell to establish a baseline for the pressure measurement system's compliance.

Datasets

The study utilized human donor eyes obtained from the North Carolina Eye Bank. No specific dataset names or identifiers are provided beyond the source of the biological material.

Key Insights and Ideas

  • Cornea as a Dynamic Buffer: The most significant insight is the clear demonstration that the cornea is not a rigid structure but actively expands and thins in response to increasing intraocular pressure. This dynamic behavior suggests a crucial role in mitigating rapid pressure fluctuations.
  • Elasticity and Pressure Damping: The pressure-volume curves exhibited a characteristic concave-up, asymptotic shape, indicative of elasticity. This means that at lower pressures, the cornea can accommodate volume changes with minimal pressure increase, acting as a shock absorber. As pressure rises, the cornea becomes less distensible, requiring larger pressure increases for further volume changes.
  • Potential Glaucoma Link: The findings offer a compelling explanation for why corneal thickness has been linked to glaucoma progression. The cornea's elastic properties might protect the eye from damaging pressure surges, and a less elastic or already "stretched" cornea (potentially thinner) might be more vulnerable to these surges.

Key Results

  • Elastic Pressure-Volume Curves: All tested corneal-scleral shells demonstrated elasticity, producing concave-up, asymptotic pressure-volume curves, similar to those observed in whole globes.
  • Slope of Elasticity: The range of the pressure-volume curve slope was 0.34 to 1.6 ± 0.29 mm Hg/µL, quantifying the cornea's resistance to pressure changes.
  • Corneal Deformation: OCT imaging revealed a mean change in the radius of curvature of 247 ± 106 µm in the tested eyes.
  • Corneal Thinning: In two eyes where full-thickness imaging was possible, corneal thickness decreased by an average of 116 ± 4 µm as pressure increased.
  • System Compliance: Control experiments showed that the tubing, infusion pump, and transducer system had very low compliance, with pressure rising sharply with minimal volume infusion, confirming that the observed elasticity was indeed from the corneal-scleral shell.

Limitations and Future Work

  • Inclusion of Scleral Rim: While an attempt was made to isolate corneal elasticity, a small scleral rim was included for mounting. This means the study didn't achieve complete isolation from the elasticity of the entire globe.
  • Cadaveric vs. Living Cornea: The use of cadaveric eyes raises questions about the direct applicability of these findings to living human corneas. Previous studies suggest cadaveric eyes might be less compliant, meaning the cornea's buffering capacity in vivo could be even greater.
  • Variability in Elasticity: Significant variability in elasticity was observed between different eyes, which the authors suggest might be influenced by factors like corneal diameter.
  • Limited OCT Imaging: OCT imaging was not performed on the initial set of eyes, and in some cases, only the central cornea was imaged.
  • Future Directions: The authors emphasize the need for further studies to determine if the observed in vitro elasticity translates to an in vivo correlation with the progression of optic nerve damage in glaucoma. They also suggest future work should investigate the relationship between corneal diameter, central corneal thickness, and pressure response.

Summary updated

Abstract

Human eye bank corneas demonstrate elasticity ex vivo, with expansion and thinning in response to increases in anterior chamber pressure. These elastic properties may serve as a buffering mechanism for microvolumetric changes in the eye, thus protecting the eye from intraocular pressure surges in vivo.
BibTeX
@inproceedings{johnson2007role,
  author = {C. Starck Johnson and Shahzad I. Mian and Sayoko E. Moroi and David L. Epstein and Joseph A. Izatt and Natalie A. Afshari},
  title = {{Role of Corneal Elasticity in Damping of Intraocular Pressure}},
  booktitle = {Investigative},
  year = {2007},
  doi = {10.1167/iovs.06-0719},
}
Figure