Robust control of interval plants: Atime domain method

Ye Zhang, Radovan KovacevicIEE 1997

TL;DR

This paper presents a novel time-domain control algorithm for "interval plants" – systems whose parameters are not precisely known but fall within defined ranges. The method guarantees robust steady-state performance, meaning the system reliably reaches its target, even with uncertainties like delays or non-minimum phase behavior, provided the plant's static gain has a consistent sign.

What Problem Does This Paper Address?

Controlling dynamic systems with uncertain parameters is a significant challenge in engineering. Many real-world processes, like those in manufacturing or robotics, cannot be modeled with exact parameter values due to variations in materials, operating conditions, or sensor noise. While "interval plants" (where parameters are known to lie within specific bounds) are a useful way to represent this uncertainty, designing controllers that guarantee performance across all possible parameter values has been difficult. Existing methods often focus on analysis rather than practical design, and those that do offer design approaches struggle with complex uncertainties. This paper aims to bridge this gap by providing a systematic, time-domain design method for interval plants that ensures robust tracking performance.

Methods

The core of the proposed method is a prediction-based control algorithm, drawing inspiration from generalized predictive control (GPC). However, instead of using exact predictions, this algorithm works with uncertainty ranges for future outputs.

Here's a breakdown of the key techniques:

  • Interval Models: The system is described by its impulse response, where each coefficient is known to be within a specific interval (e.g., $h_{min}(j) \le h(j) \le h_{max}(j)$).
  • Uncertainty Range Prediction: Instead of predicting a single output value, the algorithm predicts the range of possible future outputs. This is done recursively for one-step-ahead and multi-step-ahead predictions. The uncertainty range is directly related to the sum of the widths of the parameter intervals multiplied by the absolute values of control input changes.
  • Step Response Prediction: A crucial element is predicting the system's response if the control input were to remain constant (a "step" in control action). This prediction is also expressed as a range.
  • Robust Control Criterion: The controller is designed to ensure that the maximum possible future output, based on the step response prediction, reaches the desired set-point ($y_0$). This is formulated as: $max z_{k+n}(\Delta u_k/k) = y_0$.
  • Control Action Calculation: The control input increment ($\Delta u_k$) is then calculated based on the difference between the set-point and the predicted maximum step response, scaled by the plant's static gain (specifically, its maximum or minimum value depending on the sign of the set-point).
  • Sign Certainty Condition: A critical assumption for guaranteeing robust performance is that the sign of the plant's static gain (the sum of all impulse response coefficients) remains constant across all parameter variations. This is expressed as $S_{max}(n)S_{min}(n) > 0$.

Datasets

Not discussed in the paper. The paper focuses on theoretical development and simulation/experimental validation using defined interval plant models.

Key Insights and Ideas

  • Robustness through Range Prediction: The most significant insight is that by explicitly accounting for the range of possible future outputs, rather than just a single predicted value, robust performance can be achieved. This allows the controller to proactively counteract the worst-case scenarios arising from parameter uncertainty.
  • Static Gain Sign as a Key Enabler: The paper highlights that the "sign certainty condition" of the static gain is fundamental. If this condition holds, the controller can reliably drive the system to the set-point, regardless of other uncertainties like delays or non-minimum phase behavior. This simplifies the problem significantly.
  • Time-Domain Simplicity: Developing the algorithm in the time domain, using impulse response functions, makes it more intuitive and directly applicable to discrete-time control systems, which are common in practice.
  • Generalizability: The paper demonstrates that the approach can be extended from simple impulse response models to more general autoregressive moving-average (ARMA) interval models, increasing its practical relevance.

Key Results

  • Guaranteed Robust Steady-State Performance: The primary result is Theorem 1, which proves that the proposed algorithm guarantees the closed-loop system will track a given set-point ($lim_{k \to \infty} y_k = y_0$) if the sign certainty condition is met.
  • Effective Control of Challenging Plants: Simulations demonstrate the algorithm's effectiveness on interval plants with:
  • Open-loop delay and overshooting (Example 1).
  • Constant disturbances (Example 2).
  • Non-minimum phase characteristics (Example 3). In all cases, stable closed-loop control was achieved despite significant parameter uncertainties.

  • Successful Application to Weld Penetration Control: An application example in automated welding shows the algorithm successfully maintaining weld penetration at a desired level, even when external conditions (welding speed) were perturbed. This real-world validation underscores the practical utility of the method.

Limitations and Future Work

  • Sign Certainty Condition: The guarantee of robust performance is contingent on the sign certainty condition of the static gain. If this condition is not met, the algorithm's performance is not guaranteed.
  • Choice of Prediction Horizon: While the paper uses a prediction horizon of 'n' (the order of the system) for the control criterion, it notes that other horizons ($m < n$) could be used. However, the theoretical basis for selecting an optimal 'm' to balance regulation speed and robustness is not fully established. Future work could explore this trade-off more deeply.
  • Disturbance Handling: While Remark 4 briefly touches upon constant disturbances, the paper primarily focuses on parameter uncertainty. Extending the algorithm to handle more general or time-varying disturbances would be a valuable future direction.
  • Computational Complexity: While not explicitly detailed, the recursive nature of multi-step-ahead prediction and the calculation of uncertainty ranges can lead to computational demands, especially for high-order systems. Optimizing these computations could be an area for future research.

Summary updated

Abstract

A time-domain algorithm is proposed to control interval plants described by impulse response functions. The closed-loop control actions are determined based on the interval ranges of the model parameters. Robust steady-state performance in tracking a given set-point can be guaranteed if the sign of the static gain is certain despite possible open-loop overshooting, delay, and nonminimum phase of the interval plants. Simulation examples are given to illustrate the performance. An application example in welding process control is also included.
BibTeX
@inproceedings{zhang1997robust,
  author = {Ye Zhang and Radovan Kovacevic},
  title = {{Robust control of interval plants: Atime domain method}},
  booktitle = {IEE},
  year = {1997},
  doi = {10.1049/ip-cta:19971170},
}