Robust Control Allocation for Space Inertial Sensor under Test Mass Release Phase with Overcritical Conditions

Juzheng Zhang, Yu Zhang, Wenjian Tao, Zhenkun Lu, Mingpei Lin2023

TL;DR

This paper introduces a novel robust control allocation method for space inertial sensors during the critical test mass release phase, especially under "overcritical" conditions where uncertainties are high. The method effectively manages complex dynamics and uncertainties to ensure precise control, leading to improved capture efficiency and a greater safety margin compared to traditional approaches.

What Problem Does This Paper Address?

Drag-free spacecraft are crucial for missions requiring extreme stability, such as gravity field surveys and gravitational wave detection. A key component is the space inertial sensor (SIS), which uses a test mass as an inertial reference. During launch and orbital transfer, the test mass is secured. Upon release into the target orbit, it must be precisely controlled. However, the release process can induce residual speeds and unpredictable forces due to factors like asymmetrical adhesion. In "overcritical conditions" – characterized by significant uncertainties in the test mass's control system, including measurement errors and unexpected charge accumulation – traditional control methods struggle. This is particularly problematic for deep space missions where manual intervention is impossible due to communication delays. The paper addresses the challenge of achieving stable control of the test mass under these high-uncertainty, overcritical release conditions, aiming to prevent collisions with the electrode housing and ensure mission success.

Methods

The authors propose a 6-DOF (six degrees of freedom) robust control allocation method. The core of their approach involves:

  • Modeling Uncertainties: They first establish a 6-DOF test mass dynamics model that explicitly accounts for uncertainties in both the measurement of the test mass's state and the control voltages applied to the electrodes. This includes modeling errors arising from the test mass potentially colliding with the electrode housing, leading to charge accumulation.
  • Time-Varying Weight Function: A key innovation is the design of a time-varying weight function. This function dynamically adjusts the allocation of generalized forces and torques, prioritizing collision avoidance with the electrode housing.
  • Second-Order Cone Programming (SOCP): The robust control allocation problem is reformulated as an SOCP problem. This mathematical framework allows for efficient optimization under constraints.
  • Dual Problem for Efficiency: To further simplify computation and improve solving efficiency, the dual problem of the SOCP is introduced and utilized.
  • Knapsack Problem for Electrode Voltage Optimization: After determining the control allocation, a 0-1 knapsack problem is employed to optimize the electrode voltages. This step aims to minimize the residual potential of the test mass by intelligently distributing positive and negative electrode potentials.

Datasets

Not discussed in the paper. The paper relies on numerical simulations using parameters derived from existing literature and mission specifications (e.g., LISA Pathfinder).

Key Insights and Ideas

  • Overcritical Conditions are a Major Hurdle: The paper highlights that the "overcritical" conditions, characterized by significant and complex uncertainties, pose a substantial challenge for precise control of the test mass.
  • Robustness is Paramount: Traditional control allocation methods, which assume accurate system models, fail under these uncertain conditions. A robust approach that explicitly accounts for bounded uncertainties is essential.
  • Collision Avoidance as a Primary Objective: Unlike typical control allocation problems that focus on minimizing allocation error or energy, this work prioritizes avoiding collisions between the test mass and its housing, especially during the critical release phase.
  • SOCP as an Effective Framework: Reformulating the robust control allocation problem as an SOCP provides a mathematically sound and computationally tractable way to handle the complex optimization and uncertainty.
  • Dual Problem Simplification: Leveraging the dual problem of the SOCP significantly enhances computational efficiency, making the method more practical for real-time applications.

Key Results

The proposed robust control allocation (RobCA) method demonstrated superior performance compared to the traditional pseudo-inverse control allocation (PICA) method in numerical simulations:

  • Faster Settling Time: The test mass reached its commanded target in less than 50 seconds with RobCA, compared to over 90 seconds with PICA.
  • Reduced Oscillation: The oscillation amplitude of the test mass states (position, attitude, velocity, angular velocity) was significantly smaller with RobCA.
  • Improved Safety Margin: The nearest distance between the test mass and the electrode housing was consistently larger with RobCA, indicating a greater safety margin and reduced risk of collision.
  • Smaller Allocation Error: The average norm of force and torque allocation errors were substantially lower with RobCA (5.5 × 10⁻⁶ N and 6.2 × 10⁻⁸ Nm, respectively), representing only 79% and 43% of the PICA method's errors.
  • Acceptable Residual Voltages: The residual voltages of the test mass remained below 1V throughout the simulation, which is considered acceptable.

Limitations and Future Work

  • Synthetic Uncertainty: The proposed method models the overall uncertainty of the system but does not differentiate between individual actuator uncertainties.
  • Future Work: The authors suggest future research should focus on identifying and individually accounting for the uncertainties of specific actuators. This would further enhance the robustness and performance of the control allocation system.

Summary updated

BibTeX
@misc{zhang2023robust,
  author = {Juzheng Zhang and Yu Zhang and Wenjian Tao and Zhenkun Lu and Mingpei Lin},
  title = {{Robust Control Allocation for Space Inertial Sensor under Test Mass Release Phase with Overcritical Conditions}},
  year = {2023},
  doi = {10.3390/s23062881},
}
Figure