Retro Mode Imaging for Detection and Quantification of Sub-RPE Drusen and Subretinal Drusenoid Deposits in Age-Related Macular Degeneration

Marlene Saßmannshausen, Leyla Sautbaeva, Leon Alexander von der Emde, Marc Vaisband, Kenneth R. Sloan, Jan Hasenauer, Frank G. Holz, Thomas AchJournal of Clinical Medicine 2024 · DOI

TL;DR

This study introduces Retro mode imaging as a superior en-face imaging technique for detecting and quantifying subretinal drusenoid deposits (SDDs) and sub-RPE drusen in age-related macular degeneration (AMD). Retro mode imaging demonstrated significantly larger detection areas for these deposits compared to conventional methods, and it was also capable of identifying the earliest stages of SDDs, offering a promising new tool for understanding AMD progression.

What Problem Does This Paper Address?

Age-related macular degeneration (AMD) is a leading cause of vision loss, characterized by the presence of drusen and subretinal drusenoid deposits (SDDs). While various imaging techniques exist to detect these, quantitative data on SDDs, particularly their precise detection and measurement, has been lacking. Existing methods like near-infrared reflectance (NIR), green (G-AF), and blue (B-AF) fundus autofluorescence, and even spectral domain optical coherence tomography (SD-OCT), have limitations in comprehensively capturing the extent of these deposits. This study aims to address this gap by comparing the efficacy of Retro mode imaging against these conventional modalities for detecting and quantifying both sub-RPE drusen and SDDs, and to analyze their topographic distribution.

Methods

The researchers conducted a cross-sectional study involving 120 eyes from 90 patients with intermediate or non-exudative atrophic AMD. A multimodal retinal imaging protocol was employed, including:

  • Near-infrared reflectance (NIR)
  • Green and Blue Fundus Autofluorescence (G-AF, B-AF)
  • Retro mode imaging (deviated right - DR, and deviated left - DL)
  • High-resolution Spectral Domain Optical Coherence Tomography (SD-OCT)

Coherent en-face drusen and SDD areas were manually measured using the freehand tool in Fiji software. Drusen phenotypes were classified by correlating en-face images with SD-OCT data. The topographic distribution was analyzed using a modified Early Treatment of Diabetic Retinopathy Study (mETDRS) grid. Inter-reader agreement for SDD en-face area assessment was evaluated using the Intraclass Correlation Coefficient (ICC).

Datasets

The study utilized data from 90 subjects (120 eyes) diagnosed with intermediate or non-exudative atrophic AMD. No new datasets were created or introduced; the study evaluated existing imaging modalities on a cohort of AMD patients.

Key Insights and Ideas

  • Retro mode imaging is a game-changer for SDD detection: The most striking finding is how much more comprehensively Retro mode imaging captures the extent of drusen and SDDs compared to other methods. This suggests it's a significantly more sensitive tool for visualizing these pathological hallmarks of AMD.
  • Early SDD detection is possible: The study highlights Retro mode's ability to detect even the earliest stages of SDDs, which is crucial for understanding disease progression and potentially intervening earlier.
  • Topographic differences matter: The distinct spatial distribution of sub-RPE drusen (more perifoveal) and SDDs (more in the superior peripheral retina) suggests different underlying pathomechanisms or influences, which could be important for future research.
  • Multimodal imaging is key for classification: While Retro mode excels at detection, combining it with SD-OCT is essential for accurately classifying drusen phenotypes and understanding their structural characteristics.

Key Results

  • Largest En-Face Area: Retro mode imaging consistently identified the largest coherent en-face drusen areas, with mean areas of 105.2 ± 45.9 mm² (DL) and 105.4 ± 45.5 mm² (DR).
  • Smaller Detection Areas with Conventional Methods: In contrast, GAF (50.9 ± 42.6 mm²) and BAF (49.1 ± 42.9 mm²) showed significantly smaller en-face drusen areas (p < 0.001).
  • High Inter-Reader Agreement for Retro Mode: The inter-reader agreement for SDD en-face area determination was highest for Retro mode imaging (DR: ICC = 0.930; DL: ICC = 0.936), indicating good reproducibility.
  • Topographic Distribution: SDDs were predominantly found in the superior peripheral retina, while sub-RPE drusen were more concentrated in the perifoveal retina.
  • Early SDD Stage Detection: Retro mode imaging successfully detected early SDD stages, which were then confirmed with SD-OCT.

Limitations and Future Work

The authors acknowledge several limitations:

  • Manual Quantification Challenges: Confluent sub-RPE drusen made manual quantification difficult in some cases, limiting the number of suitable eyes for sub-analysis.
  • Peripheral SDD Diagnosis: Peripheral SDDs, sometimes outside the SD-OCT scan range, were diagnosed based on Retro mode appearance, introducing a risk of misclassification.
  • Alignment Imperfections: Manual alignment between NIR, SD-OCT, and Retro mode images could have complicated precise categorization.
  • Future Directions: The study suggests that future developments in en-face SD-OCT could offer similar distribution maps. However, a direct comparison between Retro mode and en-face OCT is still needed. They also emphasize the need for automatic algorithms to speed up quantification and the importance of evaluating the impact of SDD number or volume on AMD progression. Further research is needed to understand the clinical significance of these findings and the development of SDDs.

Summary updated

Abstract

<b>Background:</b> Drusen and drusenoid deposits are a hallmark of age-related macular degeneration (AMD). Nowadays, a multimodal retinal imaging approach enables the detection of these deposits. However, quantitative data on subretinal drusenoid deposits (SDDs) are still missing. Here, we compare the capability of en-face drusen and SDD area detection in eyes with non-exudative AMD using conventional imaging modalities versus Retro mode imaging. We also quantitatively assess the topographic distribution of drusen and SDDs. <b>Methods:</b> In total, 120 eyes of 90 subjects (mean age ± standard deviation = 74.6 ± 8.6 years) were included. Coherent en-face drusen and SDD areas were measured via near-infrared reflectance, green (G-) and blue (B-) fundus autofluorescence (AF), and Retro mode imaging. Drusen phenotypes were classified by correlating en-face drusen areas using structural high-resolution spectral domain optical coherence tomography. The topographic distribution of drusen was analyzed according to a modified ETDRS (Early Treatment of Diabetic Retinopathy Study) grid. Intraclass correlation coefficient (ICC) analysis was applied to determine the inter-reader agreement in the SDD en-face area assessment. <b>Results:</b> The largest coherent en-face drusen area was found using Retro mode imaging with a mean area of 105.2 ± 45.9 mm<sup>2</sup> (deviated left mode (DL)) and 105.4 ± 45.5 mm<sup>2</sup> (deviated right mode (DR)). The smallest en-face drusen areas were determined by GAF (50.9 ± 42.6 mm<sup>2</sup>) and BAF imaging (49.1 ± 42.9 mm<sup>2</sup>) (<i>p</i> < 0.001). The inter-reader agreement for SDD en-face areas ranged from 0.93 (DR) to 0.70 (BAF). The topographic analysis revealed the highest number of SDDs in the superior peripheral retina, whereas sub-retinal pigment epithelium drusen were mostly found in the perifoveal retina. Retro mode imaging further enabled the detection of the earliest SDD stages. <b>Conclusions:</b> Retro mode imaging allows for a detailed detection of drusen phenotypes. While hundreds/thousands of SDDs can be present in one eye, the impact of SDD number or volume on AMD progression still needs to be evaluated. However, this new imaging modality can add important knowledge on drusen development and the pathophysiology of AMD.
BibTeX
@article{samannshausen2024retro,
  author = {Marlene Saßmannshausen and Leyla Sautbaeva and Leon Alexander von der Emde and Marc Vaisband and Kenneth R. Sloan and Jan Hasenauer and Frank G. Holz and Thomas Ach},
  title = {{Retro Mode Imaging for Detection and Quantification of Sub-RPE Drusen and Subretinal Drusenoid Deposits in Age-Related Macular Degeneration}},
  journal = {Journal of Clinical Medicine},
  year = {2024},
  doi = {10.3390/jcm13144131},
}
Figure