Restoring Finger-Specific Sensory Feedback for Transradial Amputees via Non-Invasive Evoked Tactile Sensation

Manzhao Hao, Chih-Hong Chou, Jie Zhang, Fei Yang, Chunyan Cao, Peng-Yu Yin, Wenyuan Liang, Chuanxin M. Niu, Ning LanIEEE Open Journal of Engineering in Medicine and Biology 2020 · DOI

TL;DR

This paper demonstrates a non-invasive method to restore finger-specific sensory feedback for transradial amputees using Evoked Tactile Sensation (ETS). By stimulating specific areas on the stump, researchers were able to evoke neural responses in the somatosensory cortex (SI) that mirrored the natural sensory pathways of the missing fingers, allowing amputees to perceive touch in a way that feels like their original hand.

What Problem Does This Paper Address?

For individuals with transradial amputations (loss of the forearm below the elbow), controlling prosthetic hands effectively is a major challenge. A key reason for this difficulty is the lack of sensory feedback. Without the ability to "feel" what the prosthetic hand is touching, grasping objects, and sensing pressure, amputees often struggle to achieve fine motor control, leading to frustration and even rejection of otherwise functional prosthetics. This paper aims to bridge this gap by developing a non-invasive method to restore this crucial sensory information, making prosthetic hands more intuitive and useful.

Methods

The core of this study lies in using Evoked Tactile Sensation (ETS), a technique that involves electrical stimulation of specific regions on the residual limb (stump) to elicit a sensation of touch. The researchers employed Magnetoencephalography (MEG), a non-invasive neuroimaging technique, to observe the brain's response to this stimulation. Specifically, they focused on the primary somatosensory cortex (SI), the brain region responsible for processing touch.

The methodology involved:

  • Projected Finger Mapping (PFM): Identifying specific areas on the stump skin that, when stimulated, elicited sensations corresponding to individual lost fingers.
  • MEG Recording: Measuring the magnetic fields produced by electrical activity in the brain while stimulating these PFM areas. This allowed them to pinpoint where and when the brain responded to the stimulation.
  • Stimulation Parameter Variation: Testing different intensities of electrical stimulation to see how it affected the brain's response and the perceived sensation.
  • Finger Identification Task: A real-time system was developed where amputees would feel pressure on a prosthetic finger and then attempt to replicate that pressure on a corresponding finger on their intact hand. This tested their ability to identify which prosthetic finger was being stimulated and to modulate their motor response based on the sensory input.

Datasets

Not discussed in the paper. The study involved experiments with human subjects (transradial amputees).

Key Insights and Ideas

  • Direct Neural Pathway Confirmation: The study provides strong evidence for a direct, non-invasive neural pathway from the stump skin to the somatosensory cortex (SI) that can carry finger-specific sensory information. This is a significant finding for restoring naturalistic sensory feedback.
  • Mirror Imaging in the Brain: The brain's response in the SI cortex of the amputated side mirrored the typical "homunculus" map of the hand, showing a similar spatial organization as the intact contralateral hand. This suggests the brain can interpret the artificial sensation as if it were coming from the original fingers.
  • Intensity Correlation: The intensity of the brain's response in the SI cortex was directly proportional to the strength of the peripheral electrical stimulation. This indicates that the system can convey graded levels of sensation, crucial for fine motor control.
  • ETS as a Viable Interface: The results strongly support the feasibility of using ETS as a non-invasive neural interface for restoring high-fidelity, finger-specific sensory feedback for prosthetic hands.

Key Results

  • Neural Response Latency: The peak latency of the SI response was approximately 54-58 milliseconds, which is consistent with the time it takes for neural signals to travel from the skin to the SI cortex.
  • Finger Identification Accuracy: In the finger identification task, accuracy varied by finger and subject, but for some fingers, it reached 100% (Subject 4 for thumb, index, and pinky). Even for less accurate fingers, identification was significantly above chance (20%).
  • Correlation with Pressure: A positive trend was observed between the pressure applied by prosthetic fingers and the force exerted by the contralateral fingers in the identification task, suggesting that the sensory feedback could be translated into appropriate motor commands.
  • Subjective Experience: Amputees reported recognizing pressure on prosthetic fingers as if it were on their corresponding lost fingers, confirming the subjective efficacy of the ETS.

Limitations and Future Work

  • ETS Phenomenon Dependency: The current approach relies on amputees naturally exhibiting the "evoked tactile sensation" phenomenon, where specific stump areas elicit sensations of lost fingers. This phenomenon is not universal, limiting the immediate applicability to all amputees.
  • Targeted Sensory Reinnervation (TSR): The authors suggest that techniques like Targeted Sensory Reinnervation (TSR) could be used to enlarge the population of amputees who could benefit from ETS by surgically redirecting sensory nerves.
  • Closed-Loop Control Challenges: While the study demonstrates the feasibility of sensory-to-motor translation, implementing a fully closed-loop system for prosthetic control needs to address potential interference between electrical stimulation and EMG recordings.
  • Stimulation Artifacts: The paper briefly mentions potential disturbing effects of electrical stimulation on EMG recordings, which would need careful consideration for real-time closed-loop applications.
  • Further Research: Future work could focus on optimizing stimulation parameters, integrating ETS with advanced prosthetic control systems, and exploring its use in conjunction with TSR for broader patient populations.

Summary updated

Abstract

<i>Objective:</i> This study assessed the feasibility to restore finger-specific sensory feedback in transradial amputees with electrical stimulation of evoked tactile sensation (ETS). <i>Methods:</i> Here we investigated primary somatosensory cortical (SI) responses of ETS using Magnetoencephalography. <i>Results:</i> SI activations revealed a causal correlation with peripheral stimulation of projected finger regions on the stump skin. Peak latency was accountable to neural transmission from periphery to SI. Peak intensity of SI response was proportional to the strength of peripheral stimulation, manifesting a direct neural pathway from skin receptors to SI neurons. Active regions in SI at the amputated side were consistent to the finger/hand map of homunculus, forming a mirror imaging to that of the contralateral hand. With sensory feedback, amputees can recognize a pressure at prosthetic fingers as that at the homonymous lost fingers. <i>Conclusions:</i> Results confirmed that the direct neural pathway from periphery to SI allows effective communication of finger-specific sensory information to these amputees.
BibTeX
@article{hao2020restoring,
  author = {Manzhao Hao and Chih-Hong Chou and Jie Zhang and Fei Yang and Chunyan Cao and Peng-Yu Yin and Wenyuan Liang and Chuanxin M. Niu and Ning Lan},
  title = {{Restoring Finger-Specific Sensory Feedback for Transradial Amputees via Non-Invasive Evoked Tactile Sensation}},
  journal = {IEEE Open Journal of Engineering in Medicine and Biology},
  year = {2020},
  doi = {10.1109/ojemb.2020.2981566},
}
Figure