Responsible Quantum Machine Learning for Medical Imaging: A Fairness Audit Across Sensitive Subgroups

Giovanni dos Santos Franco, Felipe Mahlow, Ellison Fernando Cardoso, José Adenaldo Santos Bittencourt, Felipe FanchiniarXiv 2026

TL;DR

This paper performs one of the first empirical "fairness audits" of Quantum Machine Learning (QML) models in medical imaging, proving that quantum classifiers are not inherently immune to demographic bias. By testing hybrid classical-quantum pipelines on dermatology and radiology datasets, the authors demonstrate that while QML can be competitive, it requires the same rigorous fairness mitigation and subgroup-aware evaluation as classical AI to avoid harming underrepresented patient groups.

What Problem Does This Paper Address?

As Quantum Machine Learning (QML) moves from theoretical physics to practical applications like medical diagnosis, researchers often focus on "quantum advantage"—speed or accuracy gains. However, the "Responsible AI" dimension is frequently overlooked.

Medical AI is notorious for exhibiting performance disparities across sensitive subgroups (e.g., lower accuracy for patients with darker skin tones or different age groups). This paper addresses a critical question: Does QML inherit or amplify these biases? The authors argue that we cannot assume quantum structures are "fair by design" and must audit them against the same ethical standards as classical deep learning.

Methods

The researchers built a hybrid pipeline to compare classical and quantum classifiers on a level playing field:

  1. Feature Extraction: Images were first processed by a classical ResNet-18 (pretrained on ImageNet) to generate embeddings.
  2. Dimensionality Reduction: For the quantum models, these embeddings were compressed to 10 dimensions using Principal Component Analysis (PCA) to fit within the constraints of 10-qubit simulations.
  3. Classifiers: They compared classical models (SVM, MLP) against quantum counterparts: a Quantum Support Vector Machine (QSVM) using a fidelity kernel and a Quantum Convolutional Neural Network (QCNN) implemented as a variational circuit.
  4. Fairness Mitigation: They tested three strategies:
  5. Differentiable Equalized Odds (EO): A penalty term added to the loss function to minimize differences in group-wise mean predictions.
  6. Gradient Reversal Learning (GRL): An adversarial approach where the model tries to learn features that are useful for diagnosis but useless for identifying the patient's sensitive attribute (like age or skin type).
  7. Combined (GRL+EO): Using both techniques simultaneously.
The bias auditing pipeline used to evaluate classical and quantum models.

Datasets

The study utilized two prominent medical imaging benchmarks:

  • DDI (Diverse Dermatology Images): A dataset for skin lesion classification where the sensitive attribute is the Fitzpatrick skin type (grouped into Types I-II, III-IV, and V-VI).
  • CheXpert: A chest X-ray dataset for detecting pleural effusion, with age group (0-40, 41-60, 60+) serving as the sensitive attribute.
Class distribution across sensitive groups, showing prevalence differences that can lead to bias.

Key Insights and Ideas

  • QML is not a "Fairness Freebie": The results show that quantum models exhibit measurable subgroup disparities similar to classical models. The unique computational structure of a quantum circuit does not automatically filter out biases present in the training data.
  • The "Leveling Down" Trap: A major contribution of this paper is the use of a non-inferiority criterion. The authors point out that you can "fix" a fairness gap by simply making the model perform poorly for everyone (reducing the gap to zero). In medicine, this is unacceptable. They only consider a mitigation strategy successful if it reduces disparity without dropping global performance (AUC) by more than a small margin (0.02).
  • Model-Dataset Sensitivity: Fairness interventions are not one-size-fits-all. A strategy that worked for a QSVM on skin types often failed for a QCNN on age groups, highlighting the need for empirical auditing of every specific pipeline.

Key Results

  • DDI Performance: The QSVM with GRL+EO was a standout performer. It achieved an AUC of 0.808, approaching the performance of the state-of-the-art classical foundation model (PanDerm, AUC 0.814) while significantly reducing subgroup disparity.
  • CheXpert Performance: The QCNN with GRL achieved the highest aggregate performance among non-foundation models (AUC 0.820), but it actually increased subgroup disparity compared to its baseline. This reinforces the idea that high accuracy can mask underlying unfairness.
  • Subgroup Disparities: Baseline ROC analysis (Figure 4) revealed that even strong models like PanDerm have an AUC gap of nearly 0.10 between the best- and worst-performing skin type groups. Quantum models showed similar or even wider gaps before mitigation.

Limitations and Future Work

  • Simulation vs. Hardware: All quantum models were run in classical simulation. Real-world quantum hardware introduces noise and decoherence, which might further impact fairness and performance.
  • The PCA Bottleneck: Compressing complex medical images into just 10 principal components is a significant information bottleneck. Future work should explore higher-dimensional quantum embeddings as hardware scales.
  • Attribution of Bias: Because the pipeline uses a classical ResNet backbone, it is difficult to isolate whether the bias originates in the classical feature extractor or the quantum classifier. The authors suggest that future studies should include a "matched-capacity" classical control trained on the exact same 10-dimensional PCA features.
  • Clinical Consequences: The study uses threshold-independent metrics like AUC. The authors note that a true clinical audit would need to look at specific operating points (sensitivity/specificity) to understand the real-world impact of false negatives on different patient groups.

Summary updated

Abstract

Quantum machine learning (QML) is increasingly explored for medical classification, yet its behaviour under subgroup-aware fairness criteria remains understudied. We present an empirical fairness audit of classical and quantum classifiers for medical imaging, assuming QML is not inherently fair. Two scenarios are evaluated: dermatological lesions on DDI (sensitive attribute: Fitzpatrick skin type) and chest X-rays on CheXpert-derived data (sensitive attribute: age group). Using ResNet-18 embeddings, we train SVM, MLP, QSVM and QCNN under a baseline and three mitigation settings: differentiable Equalized Odds (EO) regularisation, Gradient Reversal Learning (GRL), and both combined. Foundation models (PanDerm, EVA-X) serve as external references. Quantum classifiers may achieve competitive aggregate performance while still exhibiting subgroup disparities. Since a smaller subgroup AUC gap may stem from degrading the best group rather than improving the worst, each mitigation is also tested against a pre-specified non-inferiority margin relative to its baseline. Under this criterion, several configurations with the smallest disparity, notably QCNN with GRL on DDI, are not clinically acceptable due to loss of global discrimination. On DDI, QSVM with GRL+EO performed best and approached PanDerm in the performance/fairness trade-off; on CheXpert, QCNN with GRL achieved the highest aggregate performance but increased disparity, and EVA-X remained stronger. Fairness effects are model- and dataset-dependent, so QML requires empirical subgroup-aware evaluation. All quantum models run in classical simulation; we claim no quantum advantage.
BibTeX
@misc{franco2026responsible,
  author = {Giovanni dos Santos Franco and Felipe Mahlow and Ellison Fernando Cardoso and José Adenaldo Santos Bittencourt and Felipe Fanchini},
  title = {{Responsible Quantum Machine Learning for Medical Imaging: A Fairness Audit Across Sensitive Subgroups}},
  year = {2026},
  eprint = {2610.37819},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.37819},
}
Figure