Abstract
With photon-number resolving detectors, we show compression of interference fringes with increasing photon numbers for a Fabry-Perot interferometer. This feature provides a higher precision in determining the position of the interference maxima compared to a classical detection strategy. We also theoretically show supersensitivity if $N$-photon states are sent into the interferometer and a photon-number resolving measurement is performed.
Introduction
Interferometry is a cornerstone of high-precision metrology, essential for applications ranging from satellite ranging to gravitational wave detection at LIGO. Traditionally, these systems rely on measuring the average intensity of light. However, this classical approach is fundamentally constrained by the "shot-noise limit" (SNL)—an uncertainty floor dictated by the discrete nature of photons. This research addresses two critical challenges in interferometry: improving resolution (the precision in locating an interference peak) and enhancing sensitivity (the ability to detect minute phase changes). By transitioning from classical intensity measurements to quantum photon-number-resolving (PNR) detection, the authors demonstrate significant improvements in both domains.
Experimental Methodology
The study combines theoretical quantum modeling with advanced experimental techniques. The primary detection tool was a Transition Edge Sensor (TES), a superconducting micro-bolometer capable of distinguishing the exact number of photons in a single pulse with approximately 95% efficiency. This contrasts with standard "click" detectors that only signal the presence of light.
The experimental setup utilized a scanning Fabry-Perot interferometer (FPI). The FPI was modeled as an effective beam splitter to derive the detection probabilities for both coherent states (standard laser light) and Fock states (quantum states with a fixed photon number). Attenuated laser pulses, averaging four photons per pulse, were transmitted through the FPI. Photon-count histograms were recorded as the phase was scanned, providing a rich dataset of pulse integral histograms and phase-mapped transmission probabilities.
Resolution and Fringe Compression
A key finding of this work is the phenomenon of "fringe compression." As the number of detected photons ($k$) increases, the interference peaks of the FPI become significantly narrower. Mathematically, the transmission probability scales as $|T|^{2k}$, effectively increasing the "finesse" of the cavity without physical modifications to the mirrors.
As shown in Figure 3, the peaks for higher $k$ values are much sharper than the classical average intensity peak. Furthermore, for coherent states, a "diagnostic dip" appears in the center of the transmission peak when the detected photon number is less than the average ($k < \bar{n}$). This feature allows for a precise estimation of the source's mean photon number without complex curve fitting. Experimentally, the standard deviation of the mean (SDM) for the 7-photon peak was nearly three times smaller than that of the classical average intensity peak, representing a substantial boost in resolution.
Sensitivity and the Shot-Noise Limit
While PNR detection improves resolution for standard laser light, the authors clarify that achieving "supersensitivity"—beating the classical shot-noise limit—requires non-classical input states. By theoretically modeling the use of $N$-photon Fock states combined with PNR measurement, they demonstrate that measurement uncertainty can drop below the SNL.
Figure 6 illustrates this theoretical advantage. The measurement uncertainty $\delta L_k^F$ for specific photon counts can reach values lower than the classical average (solid black line), indicating a path toward quantum-enhanced sensing. This effectively increases the sensitivity of the interferometer to changes in distance or phase beyond what is possible with classical light.
Discussion and Future Outlook
Despite these promising results, several experimental challenges remain. The FPI was highly sensitive to thermal fluctuations, requiring precise temperature control to maintain stability. Additionally, signal truncation occurred because the TES could only resolve up to 7 photons, leading to a slight underestimation in the reconstructed classical signal.
Future research aims to experimentally demonstrate supersensitivity using true quantum light sources, such as those generated via spontaneous parametric down-conversion. The authors also propose integrating PNR-enhanced Fabry-Perot interferometers into more complex architectures, like Michelson or Mach-Zehnder interferometers, to further push the boundaries of precision metrology.
Summary updated