Resilience of synthetic CT DL network to varying ZTE-MRI input SNR

Sandeep Kaushik, C. Cozzini, Mikael Bylund, Steven Petit, Bjoern Menze, Florian WiesingerProceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition 2024

Abstract

Many recent works have proposed methods to convert MRI into synthetic CT (sCT). While they have demonstrated a certain level of accuracy, not many have studied the robustness of those methods. In this work, we study the robustness of a multi-task deep learning (DL) model that computes sCT images from fast ZTE MR images under different levels of image noise. We evaluate its impact on radiation therapy planning. The proposed method demonstrates resilience against input noise variations. It makes way for a clinically acceptable dose calculation with a fast input image acquisition.
BibTeX
@inproceedings{kaushik2024resilience,
  author = {Sandeep Kaushik and C. Cozzini and Mikael Bylund and Steven Petit and Bjoern Menze and Florian Wiesinger},
  title = {{Resilience of synthetic CT DL network to varying ZTE-MRI input SNR}},
  booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
  year = {2024},
  doi = {10.58530/2023/5031},
}

Loading related content...