NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Residual generation for leakage signatures in water supply networks with multiple inlets

Tom Nørgaard Jensen, Carsten Skovmose Kallesøe, Rafał Wiśniewski, Jan Dimon BendtsenIFAC-PapersOnLine 2018

Abstract

Water scarcity is becoming an increasing problem worldwide, and an issue compounding the problem is water leakage in the piping networks delivering potable/consumable water to end-users (Sensus, 2012). In this paper, we consider the problem of generating a set of residuals for detecting and potentially isolating leakages in water supply networks with multiple inlets using reduced network models. Using a reduced order model of the network, the expected behaviour of the network can be estimated and then compared with actual measurements obtained from the network. The result of this comparison is a set of residuals which can be used to isolate a potential leakage. As the reduced order model is adaptive based on measurements from the network, the method is plug-and-play commissionable. In the current paper, we only consider sudden leakages as the model adaptation means that slowly developing leakages will be adapted into the parameters of the model.
BibTeX
@inproceedings{jensen2018residual,
  author = {Tom Nørgaard Jensen and Carsten Skovmose Kallesøe and Rafał Wiśniewski and Jan Dimon Bendtsen},
  title = {{Residual generation for leakage signatures in water supply networks with multiple inlets}},
  booktitle = {IFAC-PapersOnLine},
  year = {2018},
  doi = {10.1016/j.ifacol.2018.09.654},
}

Loading related content...