NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Research on the Performance of Heat Transfer Device in Enhanced Tube

Jian ChengFluid 2013

Abstract

Building a new test device of heat transfer performance in the enhanced tube,it can be used for the vaporing and condensing in tube,the vaporing and condensing outside tube.Heat transfer coefficient of refrigerant R22 and R410A was analysed in a inner threaded copper pipe with 9.52mm,3.4m of length,when the evaporation temperature is separately5℃and 10℃,the condensing temperature is separately 35℃ and 40 ℃.Combined with the experimental principle,this device can be performed on the heat transfer test of the enhanced tube in different refrigerants,it provides basis for the development of the enhanced tube.
BibTeX
@inproceedings{cheng2013research,
  author = {Jian Cheng},
  title = {{Research on the Performance of Heat Transfer Device in Enhanced Tube}},
  booktitle = {Fluid},
  year = {2013},
}

Loading related content...

Figure