Abstract
This research investigates the impact of aftershocks on the seismic damage of Concrete Filled Steel Tube (CFST) arch-column structures. By performing regression analysis on 68 sets of historical earthquake data, the study establishes a linear model for aftershock epicenter intensity. The researchers developed "equivalent earthquake waves" by combining main shock records with predicted aftershock parameters. Using elastic-plastic time history analysis, they modified the standard Park-Ang damage model with a new correction coefficient ($\gamma$). Results indicate that considering a single strong aftershock increases the structural damage index by approximately 7% to 20%, with structures designed for lower fortification intensities being the most vulnerable.
The Problem: Beyond the Main Shock
Standard seismic design codes primarily focus on the "main shock"—the single largest tremor in an earthquake sequence. However, historical events like the Wenchuan earthquake have demonstrated that structures weakened by an initial shock are significantly more susceptible to collapse during subsequent aftershocks. Current engineering practices often lack a practical, standardized method to account for this cumulative degradation. This study addresses this gap by quantifying the additional damage caused by the "one-two punch" of a main shock followed by its strongest aftershock.
Methodology: A Modified Damage Model
The researchers employed a multi-step analytical approach to bridge the gap between statistical data and structural simulation:
- Statistical Regression: Analysis of 68 historical datasets (1970–2009) from CENC and PEER to correlate main shock intensity ($I_m$) with aftershock intensity ($I_a$).
- Equivalent Wave Construction: Main shock acceleration records were concatenated with predicted aftershock records to simulate a continuous seismic sequence.
- Modified Park-Ang Model: The classic Park-Ang model calculates damage based on peak displacement and cumulative hysteretic energy. The authors introduced a damage index correction coefficient ($\gamma$) to the energy term to specifically account for the fatigue-like wear caused by aftershocks.
As shown in Figure 3, the correction coefficient $\gamma$ is highest at lower acceleration levels and gradually stabilizes as the main shock intensity increases. This suggests that the relative contribution of the aftershock to total damage is most pronounced in less severe seismic events.
Key Results and Structural Impact
The study performed simulations using two independent software packages, YJK and ABAQUS, to verify the model's reliability. The primary finding was a significant underestimation of damage in traditional models. Including the strongest aftershock increased the calculated damage index by 7.34% to 20.07% in YJK simulations, with some ABAQUS results showing increases up to 24%.
Figure 4 illustrates that the damage index $D$ for the "equivalent earthquake" is consistently higher than for the main shock alone. Notably, the percentage increase in damage is larger for structures with lower fortification intensities (e.g., 0.05g basic acceleration). This highlights a critical vulnerability: structures designed to just meet minimum safety standards for a single shock may be at high risk during a prolonged seismic sequence.
Conclusion
The proposed modified Park-Ang model provides a more realistic assessment of seismic risk for CFST arch-column structures. By incorporating the $\gamma$ coefficient, engineers can better predict the cumulative degradation caused by aftershocks. While this study focused on a single strong aftershock and specific site conditions, it establishes a robust framework for future research into multi-aftershock sequences and different structural typologies. The findings suggest that current seismic fortification standards may need to be re-evaluated to account for the cumulative energy dissipation required to survive an entire earthquake sequence.
Summary updated