Research on Phase Automatic Calibration for Monopulse Tracking Receiver

Shuo LiRadio 2008

Abstract

Based on the Single Channel Monopulse self-tracking system,this paper analyses the reasons of cross-coupling,and discusses all factors and solutions of the cross-coupling deterioration.By analyzing the limitations of several existing phase calibration methods,a new method of phase automatic calibration is put forward for engineering application in this paper.This method can be used to perform phase calibration without pointing to satellite and the stability of antenna platform,moreover,it can make a self-test and a fast fault diagnosis of tracking receiver.The test results prove that the new method has high phase calibration precision and wide application in engineering.
BibTeX
@inproceedings{li2008research,
  author = {Shuo Li},
  title = {{Research on Phase Automatic Calibration for Monopulse Tracking Receiver}},
  booktitle = {Radio},
  year = {2008},
}