Research on non-stop maintenance of sewage treatment system based on spatiotemporal redundancy regulation

Hongtao Yu, Jing Qiu, Xiongqing Yu, Haiming Shen, Xiao‐Lei Wu, Jicui WangE3S 2025

Abstract

To address the operational interruption during maintenance of sewage treatment systems, this study proposes a non-stop maintenance method based on spatiotemporal redundancy regulation (SRR). By analyzing the SRR characteristics of a tobacco manufacturing enterprise’s sewage treatment station (designed capacity: 2000 t/d; actual daily capacity: 899.68 t, load rate 45%; functional water tanks with dynamic regulation capacity of 25%-30%), a four-dimensional control strategy (“storage, retention, disposal, backup”) was designed to establish a five-stage water level linkage control process (FWLCP). Experimental results demonstrated that the low-flow operation scheme achieved a determination coefficient ($R^2=0.899$), significantly outperforming the peak shaving scheme ($R^2=0.828$). The post-maintenance chemical oxygen demand (COD) decreased from 23.86 mg/L to 20.24 mg/L ($P=0.011 < 0.05$), aligning with the 95.2% COD removal rate of the Anaerobic-Anoxic-Oxic (A2/O) treatment process. Additionally, energy consumption during maintenance was reduced by 18.7% compared to traditional methods, validating the method’s dual advantages in system stability and water quality compliance.

Introduction

In industrial manufacturing, particularly in sectors like tobacco production, sewage treatment facilities often represent a critical operational bottleneck. Traditional maintenance protocols typically necessitate a complete system shutdown, which results in significant production downtime and potential risks to effluent water quality compliance. Current redundancy theories often prioritize mechanical reliability while neglecting the dynamic requirements of biological treatment processes, such as activated sludge systems. This research introduces a Spatiotemporal Redundancy Regulation (SRR) framework to enable "zero-interruption" maintenance by leveraging existing system buffers.

Methodology

Spatiotemporal Redundancy Regulation (SRR)

The proposed framework utilizes two primary forms of redundancy within the system:

  1. Temporal Redundancy (TR): Identified through the discrepancy between design capacity (2000 t/d) and actual daily load (approximately 900 t/d), resulting in a 45% load rate.
  2. Spatial Redundancy (SR): Derived from the functional water tanks, which possess a dynamic regulation capacity of 25%–30%.

Four-Dimensional Control Strategy

A four-dimensional strategy was implemented to manage these redundancies:

  • Storage: Utilizing middle pools to dewater the system and reserve reclaimed water.
  • Retention: Implementing phased water storage to maintain front-end operations during rear-end servicing.
  • Disposal: Operating at a "low flow" state (≤ 50% of design capacity) to preserve the biological environment.
  • Backup: Maintaining a minimum 15% daily storage reserve to eliminate external water dependency.

Five-Stage Water Level Linkage Control Process (FWLCP)

The operational execution of this strategy is managed through the FWLCP, which uses automated logic to adjust flow rates based on liquid level thresholds across collection, regulating, intermediate, transfer, and clean water tanks.

The Five-Stage Water Level Linkage Control Process (FWLCP) flowchart illustrating the logic used to maintain system flow during maintenance.

Results and Discussion

Operational Stability and Efficiency

The study compared a "low-flow" operation scheme against a traditional "peak shaving" strategy. The low-flow scheme demonstrated superior stability with a determination coefficient ($R^2$) of 0.899, compared to 0.828 for peak shaving. Furthermore, the SRR method achieved an 18.7% reduction in energy consumption compared to traditional shutdown-and-restart cycles.

Water Quality Impact

Statistical analysis using I-MR control charts and two-sample equivalence tests confirmed that the maintenance process did not degrade water quality. In fact, post-maintenance Chemical Oxygen Demand (COD) levels showed a statistically significant improvement, dropping from 23.86 mg/L to 20.24 mg/L ($P=0.011$). This represents a 15.2% reduction in effluent COD while maintaining a 95.2% removal rate throughout the A2/O process.

Statistical test results confirming that the mean COD after maintenance is significantly lower than the mean before maintenance.

Conclusion

The SRR framework successfully demonstrates that underutilized system capacity can be transformed into a strategic resource for non-stop maintenance. While the method's effectiveness is currently tied to systems with significant temporal redundancy (low load rates), it provides a robust roadmap for maintaining biological stability and water quality during critical infrastructure updates. Future research should explore the applicability of this model in facilities operating closer to their maximum design capacity.

Summary updated

Abstract

To address the operational interruption during maintenance of sewage treatment systems, this study proposes a non-stop maintenance method based on spatiotemporal redundancy regulation (SRR). By analyzing the SRR characteristics of a tobacco manufacturing enterprise’s sewage treatment station (designed capacity: 2000 t/d; actual daily capacity: 899.68 t, load rate 45%; functional water tanks with dynamic regulation capacity of 25%-30%), a four-dimensional control strategy (“storage, retention, disposal, backup”) was designed to establish a five-stage water level linkage control process (FWLCP). Experimental results demonstrated that the low-flow operation scheme achieved a determination coefficient (R 2 =0.899), significantly outperforming the peak shaving scheme (R 2 =0.828). The post-maintenance chemical oxygen demand (COD) decreased from 23.86 mg/L to 20.24 mg/L (P=0.011, &lt;0.05), aligning with the 95.2% COD removal rate of the Anaerobic-Anoxic-Oxic (A2/O) treatment process. Additionally, energy consumption during maintenance was reduced by 18.7% compared to traditional methods, validating the method’s dual advantages in system stability and water quality compliance.
BibTeX
@inproceedings{yu2025research,
  author = {Hongtao Yu and Jing Qiu and Xiongqing Yu and Haiming Shen and Xiao‐Lei Wu and Jicui Wang},
  title = {{Research on non-stop maintenance of sewage treatment system based on spatiotemporal redundancy regulation}},
  booktitle = {E3S},
  year = {2025},
  doi = {10.1051/e3sconf/202563001011},
}
Figure