Abstract
Evaporative cooling technology offers significant advantages for high-power wind generator stators. This research investigates the design and performance of an epoxy resin-glass sleeve for a 3.6 MW wind generator. Through finite element analysis (FEA) and experimental testing, the study evaluates the material requirements, structural characteristics, and stability of the sleeve under operating conditions. Results indicate that while the composite material provides excellent insulation and strength, the thin-walled geometry is susceptible to instability under external pressure. The research highlights the necessity of utilizing the stator core as a structural support to enhance the sleeve's stiffness and stability.
The Challenge: Sealing the Stator
As wind turbines scale to multi-megawatt capacities, managing thermal loads in the stator becomes a critical engineering hurdle. Immersion evaporative cooling—submerging the stator in a low-boiling-point, insulating liquid—is a high-efficiency solution that enables more compact and lightweight generator designs.
However, this system relies on a specialized stator sleeve to seal the coolant within the air gap between the rotor and stator. This component must satisfy three conflicting requirements:
- Electromagnetic: It must be non-magnetic and insulating to prevent eddy current losses.
- Spatial: It must be extremely thin (approx. 4.5 mm) to maintain a small air gap.
- Mechanical: It must withstand external pressures up to 0.2 MPa without buckling.
Methodology
The researchers utilized a dual-track approach to validate the sleeve design:
- Finite Element Analysis (FEA): Using ANSYS, a numerical model was constructed with hexahedral meshing to simulate stress distribution, radial displacement, and buckling modes. Two configurations were tested: a standalone "coreless" sleeve and a "core-supported" sleeve.
- Experimental Validation: A physical prototype was manufactured and subjected to pressure tests (0.04 MPa to 0.16 MPa) to measure radial displacement and verify the simulation results.
Key Insights: The Core as a Structural Skeleton
The study's most pivotal finding is that the sleeve cannot maintain stability independently. In a standalone state, the sleeve's stability coefficient is only 0.4, indicating a high risk of failure under operational pressure. However, when the sleeve is supported by the stator core, the stability coefficient increases sevenfold to 2.8.
To ensure this support is effective, the authors propose a "hot installation" strategy. By heating the stator during assembly, the inner diameter expands, allowing for the insertion of the sleeve. As the stator cools, it shrinks around the sleeve, creating a tight interference fit that maximizes structural rigidity.
Results and Stability Analysis
The analysis confirmed that the primary failure mode is not material rupture, but elastic instability (buckling). Under a 0.2 MPa load, the maximum stress reached approximately 29.3 MPa, well within the safety margins of the epoxy resin-glass material.
The buckling simulation (Figure 6) reveals a characteristic "waveform" collapse, where the circular cross-section deforms into a corrugated shape. Experimental measurements of radial displacement (-0.14 mm to -0.59 mm) were largely consistent with the FEA predictions, confirming that the stator core successfully acts as an external skeleton to prevent collapse.
Conclusion
The research demonstrates that thin-walled epoxy resin-glass sleeves are viable for 3.6 MW wind generators, provided they are structurally integrated with the stator core. By leveraging the core's stiffness, engineers can overcome the inherent flexibility of the thin-walled composite, ensuring a reliable seal for high-efficiency evaporative cooling systems.
Summary updated