Requirements on bandpass resolution and measurement precision for LiteBIRD
S. Giardiello, A. Carones, T. Ghigna, L. Pagano, F. Piacentini, L. Montier, Ryota Takaku, Erminia Calabrese, Debabrata Adak, Erwan Allys, Ashish Anand, J. Aumont, M. Ballardini, A. J. Banday, R. B. Barreiro, N. Bartolo, S. Basak, M. Bersanelli, A Besnard, M. Bortolami, Thejs Brinckmann, F. J. Casas, K. Cheung, M Citran, Lionel Clermont, F. Columbro, A. Coppolecchia, F. Cuttaia, P. de Bernardis, E. de la Hoz, Mario de Lucia, S. Della Torre, E. Di Giorgi, P. Diego-Palazuelos, U. Fuskeland, G. Galloni, M. Galloway, M. Gerbino, M. Gervasi, R. T. Génova-Santos, C. Gimeno-Amo, A. Gruppuso, M. Hazumi, S. Henrot–Versillé, L. T. Hergt, Baptiste Jost, Kazunori Kohri, L. Lamagna, C. Leloup, François Levrier, A.i. Lonappan, M. López-Caniego, G. Luzzi, J. Macias-Perez, V Maranchery, E. Martínez-González, S. Masi, S. Matarrese, T. Matsumura, S. Micheli, M. Migliaccio, M. Monelli, G. Morgante, L. Mousset, Ryo Nagata, A. Novelli, F. Noviello, Ippei Obata, A. Occhiuzzi, A. Paiella, D. Paoletti, G. Pascual-Cisneros, G. Patanchon, Michele Pinchera, G. Polenta, L. Porcelli, Giuseppe Puglisi, N. Raffuzzi, M. Remazeilles, A. Rizzieri, M. Ruiz-Granda, J. Sanghavi, V. Sauvage, G. Savini, Maresuke Shiraishi, G. Signorelli, R.m. Sullivan, Yusuke Takase, L. Terenzi, M. Tomasi, M. Tristram, L. Vacher, B. van Tent, P. Vielva, I.k. Wehus, G. Weymann-Despres, Edward J. Wollack, Yu-Feng ZhouJournal of Cosmology and Astroparticle Physics2025 · DOI
This paper investigates how uncertainties in the frequency bandpasses of the LiteBIRD satellite's instruments can affect the measurement of primordial gravitational waves, quantified by the tensor-to-scalar ratio 'r'. The study establishes crucial requirements for bandpass resolution and measurement precision to ensure LiteBIRD can achieve its scientific goals, finding that a bandpass resolution of 1.5 GHz and a measurement error of σ ≈ 0.0089 are necessary.
What Problem Does This Paper Address?
Detecting primordial gravitational waves, a key signature of cosmic inflation, is a primary goal of next-generation CMB experiments like LiteBIRD. The amplitude of these waves is characterized by the tensor-to-scalar ratio 'r'. However, instrumental systematic effects, particularly those related to the precise knowledge of the instrument's frequency bandpasses, can mimic or distort the B-mode polarization signal, leading to biases in the 'r' measurement. This paper addresses the critical need to quantify and constrain these bandpass-induced systematic effects to ensure LiteBIRD's sensitivity to 'r' is not compromised.
Methods
The authors developed a simulation pipeline to model the impact of bandpass uncertainties on the time-ordered data (TOD) and subsequent map-making process. They introduced a mismatch between the "real" high-resolution bandpass (used for TOD) and the estimated "solver" bandpass (used for map-making). Two primary sources of error were investigated:
Bandpass Resolution: Degrading the resolution of the solver bandpass.
Measurement Error: Adding a Gaussian distributed error (with standard deviation σ) to the solver bandpass.
These effects were analyzed for three representative LiteBIRD channels (40, 140, and 402 GHz) and three different bandpass shapes (top-hat, Chebyshev order 3, and Chebyshev order 5). The analysis was performed using both a simple deprojection technique and a more sophisticated blind component separation method called Needlet Internal Linear Combination (NILC). The bias on 'r' (Δr) was calculated and compared against LiteBIRD's allocated budget for this systematic effect (Δr < 6.5 × 10⁻⁶).
Datasets
Not discussed in the paper. The study uses simulated data based on the LiteBIRD instrument specifications and foreground models (d0s0 PySM).
Key Insights and Ideas
Bandpass Precision is Crucial: Even small deviations in bandpass knowledge can introduce significant biases in the 'r' measurement, highlighting the need for precise calibration.
Resolution vs. Error Trade-off: The study explores the interplay between bandpass resolution and measurement error, finding that while both contribute to bias, they can be managed independently to meet the overall budget.
NILC's Robustness: The blind component separation technique (NILC) proves significantly more effective at mitigating bandpass-induced systematic residuals compared to simpler deprojection methods. This allows for a relaxation of the requirements on the measurement error when NILC is employed.
Channel Dependence: The impact of bandpass uncertainties varies across different frequency channels, with lower frequency channels (like LFT 40 GHz) showing greater sensitivity due to narrower bandwidths and more complex HWP Mueller matrix elements.
Key Results
Resolution Requirement: A bandpass sampling resolution of ≲ 1.5 GHz is required across all channels to keep the bias Δr below the 6.5 × 10⁻⁶ threshold.
Measurement Error Requirement: A Gaussian measurement error with a standard deviation of σ ≲ 0.0089 (for a resolution of 0.5 GHz) is necessary when using standard deprojection methods.
Combined Effects: When considering a resolution of 1 GHz and no measurement error, the total bias is Δr = 6.5 × 10⁻⁷. With a measurement error of σ = 0.0089 and a resolution of 0.5 GHz, the bias is Δr = 4.7 × 10⁻⁶. Both are within the allocated budget.
NILC Impact: Using NILC, the requirement on the measurement error can be relaxed to σ ≲ 0.05, demonstrating its power in cleaning systematic residuals.
Limitations and Future Work
Foreground Complexity: The analysis uses a simplified foreground model (d0s0 PySM) with non-spatially varying dust and synchrotron emission. The impact of more complex foreground models is deferred to future work.
HWP Ideality: While the study considers non-ideal HWP Mueller matrices, the full complexity of HWP systematics and their coupling with bandpasses is not exhaustively explored.
Computational Cost: The analysis was performed on a subset of channels due to computational constraints. Future work could extend the analysis to all channels with more complex foreground models.
FTS Resolution: The paper notes that achieving the required bandpass resolution (e.g., 0.5-1 GHz) is feasible with current Fourier Transform Spectrometer (FTS) technology.
Summary updated
Abstract
Abstract Systematic effects can hinder the sought-after detection of primordial gravitational waves, impacting the reconstruction of the B -mode polarization signal which they generate in the cosmic microwave background (CMB). In this work, we study the impact of an imperfect knowledge of the instrument bandpasses on the estimate of the tensor-to-scalar ratio r in the context of the next-generation LiteBIRD satellite. We develop a pipeline to integrate over the bandpass transmission in both the time-ordered data (TOD) and the map-making processing steps. We introduce the systematic effect by having a mismatch between the “real”, high resolution bandpass τ , entering the TOD, and the estimated one τ s , used in the map-making. We focus on two aspects: the effect of degrading the τ s resolution, and the addition of a Gaussian error σ to τ s . To reduce the computational load of the analysis, the two effects are explored separately, for three representative LiteBIRD channels (40 GHz, 140 GHz and 402 GHz) and for three bandpass shapes. Computing the amount of bias on r , Δ r , caused by these effects on a single channel, we find that a resolution ≲ 1.5 GHz and σ ≲ 0.0089 do not exceed the LiteBIRD budget allocation per systematic effect, Δ r < 6.5 × 10 -6 . We then check that propagating separately the uncertainties due to a resolution of 1 GHz and a measurement error with σ = 0.0089 in all LiteBIRD frequency channels, for the most pessimistic bandpass shape of the three considered, still produces a Δ r < 6.5 × 10 -6 . This is done both with the simple deprojection approach and with a blind component separation technique, the Needlet Internal Linear Combination (NILC). Due to the effectiveness of NILC in cleaning the systematic residuals, we have tested that the requirement on σ can be relaxed to σ ≲ 0.05.
BibTeX
@article{giardiello2025requirements,
author = {S. Giardiello and A. Carones and T. Ghigna and L. Pagano and F. Piacentini and L. Montier and Ryota Takaku and Erminia Calabrese and Debabrata Adak and Erwan Allys and Ashish Anand and J. Aumont and M. Ballardini and A. J. Banday and R. B. Barreiro and N. Bartolo and S. Basak and M. Bersanelli and A Besnard and M. Bortolami and Thejs Brinckmann and F. J. Casas and K. Cheung and M Citran and Lionel Clermont and F. Columbro and A. Coppolecchia and F. Cuttaia and P. de Bernardis and E. de la Hoz and Mario de Lucia and S. Della Torre and E. Di Giorgi and P. Diego-Palazuelos and U. Fuskeland and G. Galloni and M. Galloway and M. Gerbino and M. Gervasi and R. T. Génova-Santos and C. Gimeno-Amo and A. Gruppuso and M. Hazumi and S. Henrot–Versillé and L. T. Hergt and Baptiste Jost and Kazunori Kohri and L. Lamagna and C. Leloup and François Levrier and A.I. Lonappan and M. López-Caniego and G. Luzzi and J. Macias-Perez and V Maranchery and E. Martínez-González and S. Masi and S. Matarrese and T. Matsumura and S. Micheli and M. Migliaccio and M. Monelli and G. Morgante and L. Mousset and Ryo Nagata and A. Novelli and F. Noviello and Ippei Obata and A. Occhiuzzi and A. Paiella and D. Paoletti and G. Pascual-Cisneros and G. Patanchon and Michele Pinchera and G. Polenta and L. Porcelli and Giuseppe Puglisi and N. Raffuzzi and M. Remazeilles and A. Rizzieri and M. Ruiz-Granda and J. Sanghavi and V. Sauvage and G. Savini and Maresuke Shiraishi and G. Signorelli and R.M. Sullivan and Yusuke Takase and L. Terenzi and M. Tomasi and M. Tristram and L. Vacher and B. van Tent and P. Vielva and I.K. Wehus and G. Weymann-Despres and Edward J. Wollack and Yu-Feng Zhou},
title = {{Requirements on bandpass resolution and measurement precision for LiteBIRD}},
journal = {Journal of Cosmology and Astroparticle Physics},
year = {2025},
doi = {10.1088/1475-7516/2025/10/038},
}