Abstract
Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) allow for non-invasive investigation of cerebral functions with high temporal and spatial resolution. However, the pulse artefact (PA) significantly degrades EEG signals in the magnetic resonance (MR) scanner. This study evaluates the combination of Optimal Basis Set (OBS) and Independent Component Analysis (ICA) to optimize PA correction in resting-state EEG data. By comparing two ICA calculation intervals and four component-marking methods across 12 subjects, the researchers identified that a wavelet-based selection method provides the best balance between artefact removal and preservation of physiological neural signals, such as the alpha rhythm.
Introduction
The integration of EEG and fMRI is a powerful tool for neuroimaging, offering both high temporal and spatial resolution. Despite its potential, the MR environment introduces significant noise, most notably the Pulse Artefact (PA). The PA arises from head movement due to blood flow, head rotation, and the Hall effect. Unlike gradient artefacts, the PA is non-stationary and varies between individuals, making it difficult to remove without losing critical neural information like resting-state alpha rhythms. This study seeks to establish the optimal parameters for ICA to clean resting-state data effectively without sacrificing signal integrity.
Methods
The researchers employed a hybrid OBS-ICA approach. The process begins with the Optimal Basis Set (OBS) to remove template-based artefacts, followed by Independent Component Analysis (ICA) to isolate remaining noise sources.
The study compared two ICA calculation intervals (whole dataset vs. 700ms post-heartbeat epochs) and four marking methods for identifying artefactual components:
- Variance contribution (pvaf): Marking components explaining high signal variance during the pulse.
- Correlation (corr): Comparing components to a pulse template.
- Partial AutoCorrelation Function (PACF): Identifying rhythmic peaks matching the heart rate.
- Wavelet Analysis (wave): Using time-frequency transforms to detect frequency bursts locked to the cardiac cycle.
Data was acquired from 12 healthy volunteers using a 3T Siemens Trio MR scanner and a 63-channel EEG system, involving two 6-minute resting-state sessions per subject to ensure reliability.
Key Insights and Results
A primary finding was the "over-cleaning" trap associated with the variance-based (pvaf) method. While effective at noise reduction, it frequently deleted significant portions of the alpha rhythm, the primary neural signal of interest in resting-state studies. In contrast, the wavelet-based method emerged as a superior "surgical" tool.
By analyzing time-varying frequency content, the wavelet method distinguishes between continuous brain signals and pulsed artefacts that appear at specific moments in the cardiac cycle. It achieved a mean Quality Coefficient (QC) of 1.01 ± 0.4 in subjects with clear alpha peaks, significantly outperforming the pvaf method in preserving neural content. Furthermore, the study found that the specific selection criteria for components are more critical than the length of the data used for ICA calculation.
Conclusion
The wavelet-based OBS-ICA approach offers a reliable pipeline for cleaning resting-state EEG data recorded during fMRI. While the current method requires manual inspection—limiting its scalability for massive datasets—it provides a robust framework for preserving physiological signals. Future research should focus on automating wavelet-based detection and testing these parameters at higher magnetic field strengths (7T or above) where artefacts are even more pronounced.
Summary updated