Removal of antibiotics from black water by a membrane filtration-visible light photocatalytic system

Hongbo Liu, Haodong Zhang, Xinyi Dong, Chengyang Wu, Éric LichtfouseJournal of Water Process Engineering 2023 · DOI

TL;DR

This paper presents a novel membrane filtration-photocatalytic system using g-C₃N₄/TiO₂ composite membranes to effectively remove antibiotics (SMZ and TC) from black water. The optimized membrane achieved over 70% removal of SMZ and 60% of TC, demonstrating a promising solution for treating complex wastewater streams.

What Problem Does This Paper Address?

Antibiotic pollution is a growing concern due to their widespread use in human medicine and agriculture. A significant portion of these antibiotics are excreted and enter wastewater, posing risks to ecosystems and human health, including the development of antibiotic resistance. Traditional wastewater treatment methods are often insufficient for removing these persistent organic pollutants. Black water, in particular, presents a challenge due to its complex composition. While membrane filtration and photocatalysis are individually explored for antibiotic removal, their combined application in a single system, especially for the challenging matrix of black water, remains an area for improvement. This paper addresses the need for an efficient and integrated system to tackle antibiotic contamination in black water.

Methods

The researchers developed a composite membrane by incorporating g-C₃N₄/TiO₂ photocatalytic particles into a polyvinylidene fluoride (PVDF) membrane matrix. This was achieved through a sol-gel method for particle synthesis and a phase inversion method for membrane fabrication. The performance of these modified membranes was evaluated against standard PVDF membranes. Key techniques included:

  • Membrane Fabrication: Sol-gel synthesis of g-C₃N₄/TiO₂ particles followed by blending with PVDF and casting to form ultrafiltration membranes.
  • Characterization: Contact angle measurements for hydrophilicity, Scanning Electron Microscopy (SEM) for surface morphology and pore structure, and FTIR spectroscopy for chemical composition.
  • Performance Testing: Dead-end filtration setup to measure membrane flux and retention rates using Bovine Serum Albumin (BSA) as a model protein.
  • Photocatalytic Removal: A membrane filtration-photocatalysis system under visible light irradiation was used to test the removal of Sulfamethoxazole (SMZ) and Tetracycline (TC) in both pure water and simulated black water.
  • Mechanism Study: Quenching experiments with scavengers (ethanol, EDTA-2Na, N₂) were employed to identify the primary active species (•OH, O₂⁻•, h⁺) responsible for antibiotic degradation.

Datasets

The study utilized simulated black water, the composition of which was based on previous analytical studies of real mixed black water. The artificial wastewater included various components like COD, NH₄⁺-N, TN, TP, and PO₄³⁻-P, along with trace elements. Specific concentrations of SMZ and TC were used as target antibiotics. No new benchmark datasets were introduced; rather, existing knowledge of black water composition was leveraged.

Key Insights and Ideas

  • Synergistic Effect: The combination of membrane filtration and visible light photocatalysis in a single system significantly enhances antibiotic removal compared to either method alone.
  • Optimized Photocatalyst Loading: A specific concentration of g-C₃N₄/TiO₂ (0.03 wt%) was found to be optimal for membrane performance, balancing increased photocatalytic activity with potential aggregation issues at higher loadings.
  • Hydrophilicity and Flux Improvement: The incorporation of g-C₃N₄/TiO₂ improved membrane hydrophilicity and porosity, leading to higher pure water flux, which is crucial for practical applications.
  • Dominant Role of Holes (h⁺): The study identified photogenerated holes (h⁺) as the primary active species responsible for the degradation of SMZ and TC, with a lesser contribution from hydroxyl radicals (•OH).
  • Impact of Matrix Complexity: The complex composition of black water negatively impacts antibiotic removal efficiency due to increased membrane fouling and inhibition of photocatalytic activity.

Key Results

  • The optimized PgT-3 membrane (PVDF/g-C₃N₄/TiO₂ with 0.03 wt% photocatalyst) achieved the best performance, removing 72.8% of SMZ and 63.9% of TC from simulated black water.
  • In pure water, the PgT-3 membrane showed even higher removal rates: 70.8% for SMZ and 62.1% for TC under visible light.
  • Neutral to weakly acidic conditions (pH 5.0-7.0) were found to be most favorable for antibiotic removal.
  • The membrane exhibited good anti-fouling performance and reusability over nine cycles.
  • The presence of other pollutants in black water (TN, TP, COD) reduced the removal efficiency of SMZ and TC by approximately 20-30% compared to pure water.

Limitations and Future Work

  • Black Water Complexity: The study acknowledges that the complex composition of real black water (including TN, TP, and COD) significantly hinders the removal efficiency of antibiotics. This suggests that pre-treatment of black water might be necessary before applying this photocatalytic membrane system for optimal performance.
  • Long-Term Stability in Real Black Water: While reusability was demonstrated over nine cycles, long-term stability and performance in actual, highly variable black water environments would require further investigation.
  • Scale-Up: The study was conducted at a laboratory scale. Scaling up this technology for industrial applications would be a crucial next step.
  • Identification of Degradation Products: While the removal efficiency is reported, a detailed analysis of the degradation products of SMZ and TC would provide a more complete understanding of the process and ensure no harmful byproducts are formed.
  • Economic Feasibility: Further research into the cost-effectiveness and economic viability of this technology for large-scale implementation would be beneficial.

Summary updated

Abstract

To address the problem of pollution caused by antibiotics in black water, we synthesized membranes containing the g-C 3 N 4 /TiO 2 photocatalysts and tested them for the removal of sulfamethoxazole (SMZ) and tetracycline (TC) in pure water conditions and black water. We compared the basic membrane filtration and photocatalytic performance of the g-C 3 N 4 /TiO 2 and the PVDF membranes, and investigated the influencing factors and application aspects of membrane filtration-photocatalytic systems for antibiotic removal. The anti-fouling performance and re-usability of g-C 3 N 4 /TiO 2 membranes were investigated by evaluating the fouling reversibility of photocatalytic membranes. The results showed that g-C 3 N 4 /TiO 2 improved the porosity, hydrophilicity and permeability of the membranes significantly. PgT-3 (PVDF/g-C 3 N 4 /TiO 2 ) membrane with 0.03 wt% of g-C 3 N 4 /TiO 2 has the best overall performance with 72.8 % and 63.9 % removal efficiency for SMZ and TC respectively. Neutral or weakly acidic solution (pH = 5.0–7.0) is favorable for the removal of both study antibiotics. The complex composition of black water increased the adsorption load on the membrane and caused the inhibition of the photocatalysis of the g-C 3 N 4 /TiO 2 membrane. The absorption of visible light by g-C 3 N 4 accelerates the electron transfer rate and promotes the separation of electrons from holes. The oxidation-active substance h + produced in the system plays an important role in the removal of SMZ and TC. • PgT-3 membrane removes 72.8 % and 63.9 % of SMZ and TC from black water. • Weak acidic conditions are more conducive to the removal of antibiotics. • The produced h+ plays an important role in the removal of SMZ and TC.
BibTeX
@article{liu2023removal,
  author = {Hongbo Liu and Haodong Zhang and Xinyi Dong and Chengyang Wu and Éric Lichtfouse},
  title = {{Removal of antibiotics from black water by a membrane filtration-visible light photocatalytic system}},
  journal = {Journal of Water Process Engineering},
  year = {2023},
  doi = {10.1016/j.jwpe.2023.103605},
}
Figure