Remote Field Eddy Current Testing for Detection of Stress Corrosion Cracks in Gas Transmission Pipelines

Dae‐Won KimJournal of the Korean Magnetics Society 2006 · DOI

Abstract

Magnetic flux leakage (MFL) pigs are traditionally used for the detection of gross corrosion on steel pipelines used for the transmission of natural gas. Alternative nondestructive evaluation (NDE) modalities are required for the detection of stress corrosion cracking (SCC) which tends to exist in colonies oriented axially along the length of the pipeline. This paper describes the use of multiphase rotating magnetic fields in the remote region of the probe as a possible SCC detection mechanism. Details of a prototype pig and test rig are given and the challenges associated with the finite element modeling of the device are discussed. Initial experimental results show that this novel NDE modality is sensitive to axially oriented tight cracks.

Introduction

Gas pipelines are critical energy infrastructure, yet they are prone to degradation over time. The industry standard for inspection is the "pig"—an instrumented device that travels inside the pipe. Most pigs utilize Magnetic Flux Leakage (MFL) to identify corrosion. However, MFL has a significant blind spot: Stress Corrosion Cracking (SCC). These cracks are typically very tight and oriented axially (parallel to the pipe's length). Because MFL relies on magnetic flux "leaking" out of a defect, and axial cracks do not significantly interrupt the longitudinal flux lines used in standard pigs, they often go undetected until a catastrophic failure occurs. This research explores a Remote Field Eddy Current (RFEC) method specifically designed to detect these elusive axial anomalies.

Methodology

The proposed system utilizes a Remote Field Eddy Current (RFEC) approach characterized by two primary innovations:

  1. Multi-phase Rotating Magnetic Fields: Instead of a stationary field, the system employs a three-phase power supply to create a rotating magnetic field. This ensures that induced eddy currents intersect axial cracks at an angle, generating a detectable signal regardless of the crack's precise orientation.
  2. Remote Field Positioning: The detector is positioned in the "remote field" zone, approximately 990 mm from the exciter coil. In this region, the magnetic field has transitioned through the pipe wall and back, making the signal highly sensitive to defects on the outer surface of the pipe.
Schematic diagram of the experimental setup including the rotor, controller, and lock-in amplifier.

The experimental setup involved a prototype pig rig inside a 215.9 mm diameter steel pipe. A Lock-In Amplifier (LIA) was used to extract phase and amplitude signals from the noisy environment, followed by wavelet-based filtering to process the resulting 2D signal maps.

Experimental Results and Discussion

The study used a controlled environment with a steel pipe containing four artificial defects simulating SCC. These defects were 25.4 mm long and 4.7 mm wide, with varying penetration depths representing 80%, 60%, 40%, and 20% of the pipe wall thickness.

One of the key insights from the study is the Phase Advantage: the phase of the signal proved to be a more reliable indicator of defect depth than amplitude, as it is less susceptible to "lift-off" (the gap between the sensor and the pipe wall). Modeling these cracks remains a challenge for Finite Element Method (FEM) simulations due to their near-zero volume, requiring extremely fine and computationally expensive meshes.

2D C-scan images (mapping pipe angle vs. axial position) showing the detection of artificial axial cracks at various processing stages.

The prototype successfully detected all four artificial cracks. The system demonstrated a clear correlation between crack depth and signal strength. Even the shallowest crack (20% depth, or 0.9 mm) was detectable after signal processing. The researchers produced 2D "C-scan" images that clearly delineated the boundaries and locations of the cracks, with wavelet transforms effectively removing background noise to allow for sharp edge detection.

Conclusion

Initial experimental results indicate that this novel RFEC modality is highly sensitive to axially oriented tight cracks that traditional MFL tools miss. Future work will focus on scaling the prototype for real-world pipeline speeds and high-pressure environments, as well as investigating the system's ability to distinguish between single deep cracks and complex "colonies" of branching SCC defects found in the field.

Summary updated

Abstract

Magnetic flux leakage(MFL) 신호를 이용하여 비파괴 검사 신호를 획득하는데 주로 사용하는 감지기 또는 금속 덩어리를 의미하는 pig 이용 기술은 일반적으로 천연 가스 전송에 사용되는 강철 파이프라인 상의 대량 부식 흔적을 감지하는데 널리 이용 되어지고 있다. 이를 대체할 수 있는 비파괴 검사 기술의 양상에 대하여 소개 하자면, 지하에 매설된 가스 파이프라인의 바깥 면에 가로축을 따라 난, 부식에 의한 결함에 일반적으로 동반하는 '압력에 의한 부식 흠집(Stress Corrosion Crack : SCC)'을 탐지하는 기술이 있다. 본 논문은 가스 파이프라인 상의 가능성 있는 SCC 검출 장치로서 탐촉자의 원거리에 형성된 다상 회전 전자장 활용 기술에 대하여 논하고 있다. Pig 원형에 대한 묘사와 비파괴 신호 검사용 탐촉자에 대한 설명이 덧붙여져 있으며 결함 검지장치의 유한 요소 모델링과 연관한 부분에 관하여도 발전적으로 논하였다. 테스트 용 pig를 이용한 초기 실험 결과는 본 논문에서 보이고 있는 비파괴 검사 양식이 가스 파이프 라인의 가로축을 따라 발생한 결함에 매우 민감하게 반응하고 있음을 보이고 있다. Magnetic flux leakage (MFL) pigs are traditionally used for the detection of gross corrosion on steel pipelines used for the transmission of natural gas. Alternative nondestructive evaluation (NDE) modalities are required for the detection of stress corrosion cracking (SCC) which tends to exist in colonies oriented axially along the length of the pipeline. This paper describes the use of multiphase rotating magnetic fields in the remote region of the probe as a possible SCC detection mechanism. Details of a prototype pig and test rig are given and the challenges associated with the finite element modeling of the device are discussed. Initial experimental results show that this novel NDE modality is sensitive to axially oriented tight cracks.
BibTeX
@article{kim2006remote,
  author = {Dae‐Won Kim},
  title = {{Remote Field Eddy Current Testing for Detection of Stress Corrosion Cracks in Gas Transmission Pipelines}},
  journal = {Journal of the Korean Magnetics Society},
  year = {2006},
  doi = {10.4283/jkms.2006.16.6.305},
}

Loading related content...

Figure