Remote Blood Oxygen Estimation From Videos Using Neural Networks

Joshua Mathew, Xin Tian, Chau-Wai Wong, Simon Ho, Donald K. Milton, Min WuIEEE JBHI 2023 · OpenReview

TL;DR

This paper introduces the first convolutional neural network (CNN) approach for non-contact blood oxygen saturation (SpO2) estimation using smartphone cameras. By analyzing hand videos, their method offers a privacy-preserving and convenient alternative to traditional pulse oximetry, demonstrating improved accuracy over existing state-of-the-art techniques.

What Problem Does This Paper Address?

Peripheral blood oxygen saturation (SpO2) is a critical health indicator, especially relevant during events like the COVID-19 pandemic where low SpO2 can precede noticeable symptoms. Current methods, like fingertip pulse oximetry, are contact-based, posing risks of cross-contamination and issues with poor limb perfusion in certain patients. While smartphone cameras offer a ubiquitous sensing platform, achieving accurate SpO2 readings non-contactually is challenging due to weaker physiological signals and the broad spectral sensitivity of RGB sensors. Existing non-contact methods often rely on specialized equipment or explicit feature extraction, which can be less robust or adaptable.

Methods

The core of this work is an optophysiology-inspired CNN architecture designed to extract SpO2 information from RGB video streams of a hand. The process begins with extracting a region of interest (ROI) from the hand in the video, followed by spatial averaging to generate R, G, and B time series. These time series are then fed into the CNN. The authors propose three distinct CNN architectures that explore different ways of combining color channels and extracting temporal features:

  • Model 1 (Color Channel Mixing Followed by Feature Extraction): Combines RGB channels first, then extracts temporal features.
  • Model 2 (Feature Extraction Followed by Color Channel Mixing): Extracts temporal features from each channel separately, then fuses them.
  • Model 3 (Interleaving Feature Extraction and Channel Mixing): Alternates between color channel mixing and temporal feature extraction.

A key aspect is the focus on explainability, achieved by visualizing the learned weights of the RGB channel combinations, demonstrating how the network learns to prioritize color bands consistent with optophysiological principles.

Datasets

The primary dataset used in this study was self-collected, comprising hand video recordings and SpO2 data from fourteen participants (six males, eight females, aged 21-30). Participants were categorized by Fitzpatrick skin types. The study also mentions testing on a publicly available contact-based dataset from Nemcova et al. [19].

Key Insights and Ideas

  • Non-contact SpO2 is Feasible with Standard Smartphones: The research demonstrates that accurate SpO2 estimation can be achieved using readily available smartphone cameras, eliminating the need for specialized hardware.
  • Hand as a Privacy-Preserving ROI: Using the hand for SpO2 measurement is proposed as a more privacy-conscious alternative to facial measurements, especially relevant in contexts where face masks are common.
  • Optophysiology-Inspired CNNs for Explainability: Designing CNN architectures based on the underlying physiological principles of light absorption by hemoglobin allows for visualization of learned weights, providing insights into why the model works and building trust in its predictions.
  • Red and Blue Channels Dominate: Visualizations of learned RGB channel weights strongly suggest that red and blue light absorption differences are the primary drivers for SpO2 estimation, aligning with established optophysiological understanding.
  • Skin Type and Hand Side Matter: The study reveals that skin tone and whether the palm or back of the hand is used can impact SpO2 estimation accuracy, with darker skin tones and palm-up positions showing some advantages in certain scenarios.

Key Results

  • The proposed CNN models achieved better performance (higher correlation, lower MAE and RMSE) compared to the state-of-the-art contact-based model from Ding et al. [7] in participant-specific experiments.
  • Model 1 showed the best performance in leave-one-participant-out experiments, suggesting its learned features generalize well.
  • The models achieved estimation errors within the 4% range, which is within the international standard for clinically acceptable pulse oximeters.
  • Bayesian statistical tests indicated that skin type and hand side have a statistically significant impact on SpO2 prediction accuracy, particularly in the leave-one-participant-out setting.
  • Ablation studies confirmed the necessity of nonlinear channel combinations and convolutional layers for optimal performance.
  • The models also showed promising results on a contact-based dataset, outperforming existing methods.

Limitations and Future Work

  • Dataset Size: The authors acknowledge that the modest size of their self-collected dataset might limit the generalization capability of the models, suggesting that a larger and richer dataset could improve performance.
  • Measurement Duration: While the current method uses 10-second segments, future work aims to investigate shorter measurement durations, which are often preferred in clinical settings.
  • Motion Artifacts: The current study focuses on still hands. Future research will explore the effectiveness of the method when participants are in motion, which is a significant challenge for video-based physiological sensing.
  • Clinical Validation: The paper suggests investigating the effectiveness and performance of the proposed method in actual clinical or physiological applications.

Summary updated

Abstract

Peripheral blood oxygen saturation (SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> ) is an essential indicator of respiratory functionality and received increasing attention during the COVID-19 pandemic. Clinical findings show that COVID-19 patients can have significantly low SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> before any obvious symptoms. Measuring an individual's SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> without having to come into contact with the person can lower the risk of cross contamination and blood circulation problems. The prevalence of smartphones has motivated researchers to investigate methods for monitoring SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> using smartphone cameras. Most prior schemes involving smartphones are contact-based: They require using a fingertip to cover the phone's camera and the nearby light source to capture reemitted light from the illuminated tissue. In this paper, we propose the first convolutional neural network based noncontact SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> estimation scheme using smartphone cameras. The scheme analyzes the videos of an individual's hand for physiological sensing, which is convenient and comfortable for users and can protect their privacy and allow for keeping face masks on. We design explainable neural network architectures inspired by the optophysiological models for SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> measurement and demonstrate the explainability by visualizing the weights for channel combination. Our proposed models outperform the state-of-the-art model that is designed for contact-based SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> measurement, showing the potential of the proposed method to contribute to public health. We also analyze the impact of skin type and the side of a hand on SpO <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$_{2}$</tex-math></inline-formula> estimation performance.
BibTeX
@article{mathew2023remote,
  author = {Joshua Mathew and Xin Tian and Chau-Wai Wong and Simon Ho and Donald K. Milton and Min Wu},
  title = {{Remote Blood Oxygen Estimation From Videos Using Neural Networks}},
  journal = {IEEE J. Biomed. Health Informatics},
  year = {2023},
  url = {https://openreview.net/forum?id=OpRS2q1YX4},
}
Figure