Remediation of Micro-Pollution in an Alkaline Washing Solution of Fly Ash Using Simulated Exhaust Gas: Parameters and Mechanism

Lei Wang, Yuemei Tang, Yu Gong, Xiang Shao, Xiaochen Lin, Weili Xu, Yifan Zhu, Yongming Ju, Lili Shi, Dorota KołodyńskaSustainability 2023 · DOI

TL;DR

This paper presents a novel method for simultaneously treating hazardous wastewater from fly ash (FA) and capturing CO2. By bubbling simulated industrial exhaust gases through alkaline FA washing solutions, researchers effectively removed heavy metals like lead and neutralized alkalinity, meeting strict environmental standards. This dual-purpose approach offers a promising pathway for sustainable waste management and carbon capture.

What Problem Does This Paper Address?

Municipal solid waste incineration (MSWI) is a growing waste management strategy, but it generates hazardous alkaline fly ash (FA). The washing solutions used to treat this FA contain significant amounts of heavy metals (HMs) and are highly alkaline, posing environmental risks. Simultaneously, global CO2 emissions from industrial sources are a major concern. This research tackles the challenge of efficiently remediating these FA washing solutions while also contributing to carbon capture efforts, aiming for a win-win solution.

Methods

The study employed a gas-bubbling approach using simulated industrial exhaust gases (specifically, CO2 mixed with N2) to treat FA washing solutions. Key experimental parameters investigated included:

  • CO2 partial pressure: Two levels were tested (15% and 33%).
  • Temperature: Experiments were conducted at 25 °C, 50 °C, and 80 °C.
  • Gas flow rate: Various flow rates (10, 15, 30, 45, and 61 sccm) were explored.
  • Liquid-to-solid ratio (L/S): Optimized to 8 mL/g for washing the FA.

The researchers monitored the removal efficiency of target pollutants (primarily Pb ions) and the change in pH over time. They also analyzed the precipitated particles using techniques like X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), Energy-Dispersive X-ray Spectroscopy (EDS), and X-ray Photoelectron Spectroscopy (XPS) to understand their composition and morphology. Kinetic studies (pseudo-first-order) and thermodynamic analysis (free energy, enthalpy, entropy) were performed to elucidate the reaction mechanism.

Datasets

Not discussed in the paper. The study utilized fly ash collected from a municipal solid waste incineration facility in Suzhou, China, and simulated industrial exhaust gases.

Key Insights and Ideas

  • Dual-purpose remediation: The core innovation is the simultaneous treatment of hazardous FA washing solutions and CO2 sequestration using a single process. This highlights the potential for waste valorization to address environmental challenges.
  • Optimized conditions are crucial: The study found that lower temperatures (25 °C) and moderate gas flow rates (15 sccm) were optimal for Pb removal, suggesting that high temperatures can be detrimental to the process.
  • Mechanism of Pb removal: Pb removal is attributed to the formation of calcium carbonate (CaCO3) precipitates, which effectively trap Pb ions. The process involves the transformation of Pb hydroxides into Pb carbonates.
  • Thermodynamics of Pb removal: The removal of Pb ions is a spontaneous, exothermic, and entropy-decreasing process, indicating a favorable reaction under the tested conditions.
  • Safe and useful byproducts: The precipitated CaCO3 particles were found to be non-toxic and showed potential as adsorbents for dyes, suggesting a pathway for their reuse.

Key Results

  • High Pb removal efficiency: Under optimal conditions (25 °C, 15 sccm flow rate, 33% CO2), the removal efficiency for Pb ions reached 97.9–99.2%.
  • Meeting regulatory standards: The treated washing solutions met the regulatory threshold values for HMs and pH according to China's integrated wastewater discharge standard (GB 8978–1996). For example, residual Pb was below 1.0 mg/L, and the final pH was between 6 and 8.
  • Pseudo-first-order kinetics: The initial removal of Pb ions (within 40 minutes) followed a pseudo-first-order kinetic model.
  • CaCO3 precipitation: The precipitated particles were identified as a mixture of calcite and vaterite CaCO3.
  • Non-toxic precipitates: Acute toxicity tests on zebrafish showed 0% mortality for the obtained particles, indicating their safety.

Limitations and Future Work

  • Simulated vs. Real Exhaust Gas: The study used simulated exhaust gases. Future work should investigate the effectiveness of this method with actual flue gases from power plants and cement/steel industries, which may contain other complex components.
  • Other HMs: While Pb removal was highly effective, the removal efficiencies for other HMs like Cr and As showed less consistent patterns and require further investigation.
  • Long-term stability: The long-term stability and potential leaching of HMs from the precipitated CaCO3 need to be assessed for practical applications.
  • Scale-up: The study was conducted at a laboratory scale. Further research is needed to evaluate the feasibility and efficiency of this process at an industrial scale.
  • Optimization of flow rates: While 15 sccm was found to be optimal, exploring flow rates beyond 30 sccm and 45 sccm could be beneficial for HM removal in the washing solution.

Summary updated

Abstract

Currently, there is an urgent need to remediate heavy metals (HMs) and high alkalinity in the washing solution of fly ash (FA). This study investigated the remediation with simulated exhaust gases of two CO2 partial pressure and revealed the removal efficiency of target pollutants, mainly including Pb ions. The results verify that under the preferred conditions of 25 °C and 15 mL/min flow rate, bubbling two kinds of simulated flue gases could efficiently remove 97.9–99.2% of Pb ions. Moreover, the initial 40 min removal of Pb ions fits in a way with a pseudo-first-order equation. Based on the thermodynamic parameters, we infer that the removal of Pb ions was a spontaneous, exothermic, and entropy-decreasing process. Furthermore, residual HMs and terminal pH after remediation of the FA washing solution basically met the regulatory threshold values of the integrated wastewater discharge standard in China (GB 8978−1996). Additionally, the particles obtained from the washing solution of FA were identified as CaCO3, which was mainly composed of vaterite and calcite crystalline. This study provides a fundamental guide for remediating multiple pollutants in the washing solution of FA and simultaneously sequestrating carbon emissions from power plants and industries.
BibTeX
@inproceedings{wang2023remediation,
  author = {Lei Wang and Yuemei Tang and Yu Gong and Xiang Shao and Xiaochen Lin and Weili Xu and Yifan Zhu and Yongming Ju and Lili Shi and Dorota Kołodyńska},
  title = {{Remediation of Micro-Pollution in an Alkaline Washing Solution of Fly Ash Using Simulated Exhaust Gas: Parameters and Mechanism}},
  booktitle = {Sustainability},
  year = {2023},
  doi = {10.3390/su15075873},
}
Figure