Regularized Compression of MRI Data: Modular Optimization of Joint Reconstruction and Coding

Veronica Corona, Yehuda Dar, Carola-Bibiane SchönliebarXiv 2020 · OpenReview

TL;DR

This paper introduces a novel framework for jointly optimizing MRI image reconstruction and lossy compression. By integrating total-variation regularization directly into the compression process, they achieve significantly improved image quality and compression efficiency, even demonstrating that lossy compression can enhance reconstruction quality.

What Problem Does This Paper Address?

Medical imaging systems, particularly MRI, involve a pipeline of data acquisition, reconstruction, and compression. Traditionally, these stages are optimized independently, leading to suboptimal overall performance. Specifically, raw MRI data is acquired, then reconstructed into an image, which is then compressed for storage or transmission. This decoupled approach can lead to information loss and error propagation. The challenge is to create a system where reconstruction and compression work together synergistically to produce high-quality medical images at reduced data sizes, which is crucial for efficient storage, transmission, and clinical diagnosis.

Methods

The authors propose a modular optimization framework that leverages the Alternating Direction Method of Multipliers (ADMM) to jointly optimize MRI reconstruction and lossy compression. The core idea is to treat a state-of-the-art image compression technique (like BPG) as a "black-box" module within an iterative optimization process. A key novelty is the incorporation of total-variation (TV) regularization directly into the compression stage of this modular framework. This means that instead of applying TV regularization after decompression to clean up artifacts, it's integrated during the compression optimization, leading to better decompressed image quality without requiring additional post-processing. The ADMM algorithm is used to efficiently solve the complex optimization problem by splitting it into manageable sub-problems, including one for compression and another for reconstruction.

Datasets

The experiments were conducted on several datasets:

  • Brain 1, 2, and 3: T1-weighted 3D MPRAGE MRI data.
  • Liver: 4DMRI data acquired during free-breathing.

These datasets were used to evaluate the proposed method across various acceleration factors (e.g., 2x, 4x, 8x, representing the fraction of k-space data acquired).

Key Insights and Ideas

  • Synergy of Joint Optimization: Reconstructing and compressing MRI data together, rather than separately, yields significant improvements in image quality and compression efficiency.
  • Lossy Compression as Regularization: Surprisingly, lossy compression itself can act as a form of regularization, improving the reconstruction quality compared to lossless compression or no compression at all.
  • Integrated Regularization: Applying total-variation regularization during the compression optimization (rather than as a post-processing step) is highly effective, leading to superior decompressed image quality.
  • Modularity and Compatibility: The framework's modular design allows it to work with existing compression standards (like BPG) and doesn't require special decompression procedures, making it practical for real-world applications.

Key Results

The proposed joint optimization method demonstrated substantial gains:

  • Without TV Regularization: The proposed method achieved significant PSNR gains of 4 to 9 dB at high bit-rates compared to a joint optimization approach without TV regularization.
  • With TV Regularization: Compared to a decoupled approach (where reconstruction and compression are done separately, even with TV regularization), the proposed method achieved PSNR gains of 0.5 to 1 dB at high bit-rates.
  • Visual Quality: Visual results showed clear improvements in image quality, with fewer artifacts and sharper details, especially at higher compression levels.

Limitations and Future Work

  • Parameter Tuning: The paper mentions that the auxiliary parameter $\beta$ in the ADMM algorithm was empirically set based on the compression's quantization parameter (QP). Further research could explore automated or adaptive parameter optimization.
  • Regularizer Exploration: While total-variation regularization was used, the authors suggest exploring other types of regularizers for different imaging tasks or data characteristics.
  • Bi-level Optimization: The authors propose exploring bi-level optimization for automated parameter tuning as a future direction.

Summary updated

Abstract

The Magnetic Resonance Imaging (MRI) processing chain starts with a critical acquisition stage that provides raw data for reconstruction of images for medical diagnosis. This flow usually includes a near-lossless data compression stage that enables digital storage and/or transmission in binary formats. In this work we propose a framework for joint optimization of the MRI reconstruction and lossy compression, producing compressed representations of medical images that achieve improved trade-offs between quality and bit-rate. Moreover, we demonstrate that lossy compression can even improve the reconstruction quality compared to settings based on lossless compression. Our method has a modular optimization structure, implemented using the alternating direction method of multipliers (ADMM) technique and the state-of-the-art image compression technique (BPG) as a black-box module iteratively applied. This establishes a medical data compression approach compatible with a lossy compression standard of choice. A main novelty of the proposed algorithm is in the total-variation regularization added to the modular compression process, leading to decompressed images of higher quality without any additional processing at/after the decompression stage. Our experiments show that our regularization-based approach for joint MRI reconstruction and compression often achieves significant PSNR gains between 4 to 9 dB at high bit-rates compared to non-regularized solutions of the joint task. Compared to regularization-based solutions, our optimization method provides PSNR gains between 0.5 to 1 dB at high bit-rates, which is the range of interest for medical image compression.
BibTeX
@misc{corona2020regularized,
  author = {Veronica Corona and Yehuda Dar and Carola-Bibiane Schönlieb},
  title = {{Regularized Compression of MRI Data: Modular Optimization of Joint Reconstruction and Coding}},
  year = {2020},
  eprint = {2010.04065},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2010.04065},
}
Figure