Refractive error after phacoemulsification combined with intraocular lens implantation in primary angle-closure glaucoma: a multifactorial analysis of biometric parameters and surgical strategies

Yong Liu, Kuanrong Dang, Di Gong, Simin Deng, Yin Deng, Junhong Guo, Xiaoli Shen, Jiantao WangFrontiers in Cell and Developmental Biology 2025 · DOI

This study, published in Frontiers in Cell and Developmental Biology, investigates why patients with Primary Angle-Closure Glaucoma (PACG) often experience "refractive surprises" after cataract surgery. By analyzing 404 cases, researchers identified specific anatomical thresholds—such as axial length and lens thickness—that clinicians can use to better predict postoperative vision and adjust artificial lens (IOL) power.

TL;DR

Standard formulas for calculating intraocular lens power often fail in glaucoma patients due to their unique ocular anatomy. This study identifies key biometric "warning thresholds" (like an axial length of 22.56 mm) that significantly increase the risk of refractive errors, providing a data-driven roadmap for more accurate surgical planning.

What Problem Does This Paper Address?

In modern ophthalmology, cataract surgery (phacoemulsification) is often combined with other procedures to treat Primary Angle-Closure Glaucoma (PACG). While the surgery is effective at lowering intraocular pressure, predicting the final refractive outcome (whether the patient will be near-sighted or far-sighted) is notoriously difficult.

PACG eyes are "crowded"—they typically have shorter axial lengths, shallower anterior chambers, and thicker lenses compared to the general population. Because standard IOL power formulas were largely designed for "normal" eyes, they often result in significant prediction errors in PACG patients. The authors sought to identify which specific anatomical factors lead to these errors and how different surgical combinations (like adding a capsular tension ring) influence the final result.

Methods

The researchers conducted a retrospective analysis of 404 PACG patients treated at Shenzhen Eye Hospital between 2019 and 2024.

  • Biometrics: Preoperative measurements were taken using the IOL-Master 700, including axial length (AL), lens thickness (LT), and white-to-white distance (WTW).
  • Calculations: The Barrett Universal II formula—a gold standard in the field—was used to calculate IOL power.
  • Analysis: The team used Spearman correlation to find relationships between variables and multinomial logistic regression to identify independent risk factors. Crucially, they employed Receiver Operating Characteristic (ROC) curve analysis to determine specific numerical "cut-off" values that signal a high risk of refractive shift.

Datasets

The study utilized a clinical dataset of 404 PACG patients. While not a public benchmark dataset common in computer science, it represents a substantial clinical cohort for this specific sub-field. Data included comprehensive preoperative biometrics and postoperative refractive measurements taken 3–6 months after surgery.

Key Insights and Ideas

  • The "Crowded Eye" Paradox: Even within the PACG population, small differences in anatomy lead to opposite errors. Longer eyes (for this group) tend toward a myopic shift (near-sightedness), while shorter eyes tend toward a hyperopic shift (far-sightedness).
  • The AL/CR Ratio: The ratio of axial length to corneal radius (AL/CR) emerged as a more sensitive predictor than axial length alone. A ratio >2.986 was a strong indicator of postoperative myopic shift.
  • Surgical Interference: Combining cataract surgery with a Capsular Tension Ring (CTR)—often used to stabilize the lens—significantly increased the risk of hyperopic shifts. The authors suggest the ring might push the IOL further back in the eye than the formula expects.
  • Independent Predictors: WTW (white-to-white distance) was identified as an independent risk factor for hyperopic shift, suggesting that the horizontal diameter of the cornea plays a hidden role in how the artificial lens eventually settles.

Key Results

The study identified several critical "warning thresholds" for clinicians:

  • Myopic Shift (MS) Risk: Increased significantly when AL > 22.56 mm (AUC = 0.692) or LT > 5.055 mm (AUC = 0.633).
  • Hyperopic Shift (HS) Risk: Increased when AL < 22.25 mm (AUC = 0.604) or WTW < 11.55 mm (OR = 2.209).
  • Refractive Stability: Patients receiving a CTR had a significantly higher proportion of hyperopic shifts (Z value = +2.95).
  • Predictive Power: Each 1 mm increase in axial length reduced the risk of a myopic shift by approximately 65%.

Limitations and Future Work

The authors acknowledge that while their identified factors are statistically significant, the AUC values (mostly < 0.7) indicate that these parameters have "mild to moderate" discriminatory power when used alone. This suggests that refractive error is truly multifactorial and cannot be solved by a single measurement.

Future Directions: 1. Dynamic Monitoring: The study was retrospective; future work should use intraoperative OCT (Optical Coherence Tomography) to track exactly where the IOL sits in real-time during surgery. 2. Machine Learning: The authors propose integrating these biometric thresholds into machine learning algorithms to create "adaptive" IOL prediction models specifically for glaucoma patients. 3. Long-term Tracking: Extending the follow-up beyond six months to see if refractive stability holds as the eye continues to heal and remodel after pressure reduction.

Summary updated

Abstract

The unique anatomical characteristics of PACG patients are key contributors to postoperative refractive instability. Preoperative assessment for PE + IOL surgery should comprehensively evaluate AL, LT, WTW, and AL/CR ratio. When combined with other surgical approaches to control intraocular pressure, IOL power should be adjusted according to these thresholds to ensure postoperative refractive stability.
BibTeX
@inproceedings{liu2025refractive,
  author = {Yong Liu and Kuanrong Dang and Di Gong and Simin Deng and Yin Deng and Junhong Guo and Xiaoli Shen and Jiantao Wang},
  title = {{Refractive error after phacoemulsification combined with intraocular lens implantation in primary angle-closure glaucoma: a multifactorial analysis of biometric parameters and surgical strategies}},
  booktitle = {Frontiers in Cell and Developmental Biology},
  year = {2025},
  doi = {10.3389/fcell.2025.1654719},
}
Figure