TL;DR
This paper introduces three standardized reference power cable models (33 kV, 66 kV, and 132 kV) designed for floating offshore wind turbines (FOWTs). These models, characterized by detailed structural and mechanical properties derived from FEM simulations, are crucial for accurate global dynamic response simulations and the development of more cost-effective offshore wind energy systems.
What Problem Does This Paper Address?
The offshore wind industry is rapidly scaling up, with a significant shift towards floating platforms to access deeper waters. This necessitates robust and reliable dynamic power cables that can withstand the complex motions induced by environmental forces. However, a lack of standardized, readily usable reference models for these dynamic cables hinders accurate simulation and design optimization, which is critical as cable costs can represent 20-30% of total capital expenditure. This paper aims to fill this knowledge gap by developing and validating three baseline power cable designs suitable for large FOWTs.
Methods
The study employs a two-step approach:
- Local Analysis (UFLEX): A specialized finite element method (FEM) software, UFLEX, was used to model the detailed cross-sections of three power cable variants (33 kV, 66 kV, and 132 kV). This involved extensive mesh sensitivity studies to ensure accuracy. UFLEX's non-linear continuum mechanics capabilities were leveraged to capture the complex behavior of the multi-layered, helically wound cable structure, including friction and sliding between components. This step generated a comprehensive database of the cables' bending, tension, and torsion characteristics.
- Global Analysis (OrcaFlex): The non-linear mechanical properties derived from UFLEX were imported into OrcaFlex, a global dynamic analysis software. This allowed for the simulation of the coupled FOWT-power cable system under various environmental conditions, specifically focusing on a lazy wave configuration for the power cable connected to an OC3 5MW reference wind turbine.
Datasets
The study utilizes the OC3 5MW reference wind turbine specifications (Jonkman et al. [45]) and environmental conditions based on a joint probability model representative of a North Sea location (Johannessen et al. [50]). The wind field data was generated using TurbSim (NREL [52]), and the current profile followed DNV-RP-C205 [53]. The study also references existing datasets and models from previous research (e.g., Ramachandran et al. [55]) for validation purposes. No new benchmark datasets were introduced.
Key Insights and Ideas
- Standardization is Key: The development of standardized reference power cable models is essential for advancing the design and cost-effectiveness of floating offshore wind farms.
- Complex Cable Behavior: Dynamic power cables exhibit highly non-linear mechanical behavior due to internal friction and the interaction of multiple layers, which requires specialized FEM tools like UFLEX for accurate modeling.
- Lazy Wave Configuration: The lazy wave configuration is a viable and effective method for managing the dynamic power cable's response in FOWT applications.
- Minimal Impact on FOWT Dynamics: The inclusion of the dynamic power cable in the lazy wave configuration had a negligible impact on the overall response characteristics of the OC3 5MW FOWT, except for a slight amplification in the sway motion at low frequencies.
- Favorable Fatigue Performance: Simplified fatigue analysis suggests that the proposed cable designs can withstand representative environmental loading scenarios, indicating good dynamic performance.
Key Results
- Three reference power cable models (33 kV, 66 kV, 132 kV) with detailed structural and mechanical property databases were developed.
- The study demonstrated that the dynamic power cable, configured in a lazy wave layout, did not significantly alter the global response characteristics of the OC3 5MW FOWT, with the exception of a minor increase in sway motion.
- A simplified fatigue analysis indicated that the proposed cable designs are capable of sustaining typical environmental loading conditions, showing favorable dynamic performance.
- The capacity curves for the 66 kV variant showed that the plastic limit of the copper conductor is the governing factor for cable capacity, rather than the yield strength of the armor wires.
- The effective tension and curvature envelopes under extreme 50-year storm conditions remained well within the safe operational limits of the cable.
Limitations and Future Work
- Simplified Fatigue Analysis: The fatigue analysis presented is simplified and based on stress cycle counting (S-N curves) due to software limitations. The authors acknowledge that strain-based (ε-N) curves are more appropriate for copper conductors, especially considering plastic straining and creep effects. A more advanced algorithm would be needed to account for frictional stress more accurately.
- Short-Term Fatigue: The fatigue analysis was based on short-term (3-hour) time series. A full long-term fatigue analysis, considering a comprehensive joint probability distribution of environmental conditions, is beyond the scope of this study but is recommended for more accurate fatigue damage estimation.
- Generic FOWT Application: The study uses a generic OC3 5MW FOWT and a simplified environmental scenario for the fatigue analysis. Site-specific environmental conditions are crucial for accurate fatigue damage estimation in real-world applications.
- Future Work: The authors suggest that the developed reference cable models and methodology can be extended to investigate other cable configurations and FOWT designs. Further research into more advanced fatigue analysis methods, including strain-based approaches and site-specific environmental data, is also warranted.