Recruitment of motor units in two fascicles of the semispinalis cervicis muscle

Jochen Schomacher, Jakob Lund Dideriksen, Dario Farina, Deborah FallaJournal of Neurophysiology 2012 · DOI

TL;DR

This study reveals that different parts (fascicles) of the semispinalis cervicis muscle in the neck receive distinct neural control signals. This non-uniform input explains why motor units in lower neck levels are activated earlier than those in higher levels, suggesting a specialized control strategy for this complex muscle.

What Problem Does This Paper Address?

The human body is a marvel of intricate engineering, and muscles are no exception. While we often think of a muscle as a single unit, many muscles are composed of distinct bundles of fibers called fascicles. These fascicles can have different mechanical roles and, consequently, might be controlled by the nervous system in unique ways. The semispinalis cervicis muscle in the neck is a prime example of such complexity, spanning multiple spinal segments and contributing to various movements like extension, flexion, and rotation. However, how the nervous system precisely controls these different fascicles, especially during tasks like maintaining posture or extending the neck, has been unclear. Specifically, the authors aimed to understand if motor units within different fascicles of the semispinalis cervicis muscle receive the same or different neural input, and how this might influence their recruitment during neck extension.

Methods

The researchers employed a combination of advanced electromyography (EMG) techniques and controlled experimental tasks.

  • Intramuscular EMG Recordings: Fine wire electrodes were inserted into two specific fascicles of the semispinalis cervicis muscle at the C2 and C5 spinal levels in healthy volunteers. This allowed for the precise recording of electrical activity from individual motor units.
  • Motor Unit Identification and Analysis: Sophisticated decomposition algorithms were used to identify and isolate the action potentials of individual motor units from the complex EMG signals. This enabled the analysis of their discharge rate, variability, and synchronization.
  • Isometric Neck Extension Tasks: Participants performed two types of isometric neck extension tasks:
  • Sustained contractions: Holding a submaximal force (5%, 10%, 20% of maximum voluntary contraction - MVC) for an extended period (2 min).
  • Ramped contractions: Gradually increasing force from 0% to 30% MVC over 3 seconds.
  • Interference EMG: In a second experiment, global muscle activity was measured using surface EMG during ramped contractions (0-50% MVC) to assess overall muscle activation patterns.
  • Synchronization and Coherence Analysis: Techniques like cross-histograms and coherence analysis were used to quantify the degree of synchronized firing between pairs of motor units, providing insights into the common neural input they receive.

Datasets

Not discussed in the paper. The study utilized data collected from human participants during controlled experimental tasks.

Key Insights and Ideas

  • Fascicle-Specific Neural Control: The most striking finding is that different fascicles of the semispinalis cervicis muscle (specifically at C2 and C5 levels) are not controlled uniformly. They receive distinct synaptic input, leading to differences in how their motor units are recruited.
  • Recruitment Order Matters: Motor units in the lower cervical region (C5) are recruited at lower force levels compared to those in the upper cervical region (C2). This suggests a hierarchical control strategy where lower levels are "turned on" earlier.
  • Synchronization Reflects Input: Motor units within the same fascicle show higher levels of synchronization (firing together more often) than motor units from different fascicles. This strongly supports the idea of independent neural input to each fascicle.
  • Mechanical Advantage Plays a Role: The observed differences in recruitment and input are likely linked to the distinct mechanical roles of these fascicles. Lower segments of the spine experience greater mechanical loads, requiring earlier activation of their respective motor units to maintain stability.

Key Results

  • Recruitment Thresholds: Motor units at C2 had a significantly higher recruitment threshold (10.3 ± 6.0% MVC) compared to C5 (6.9 ± 4.3% MVC) (P < 0.01).
  • Motor Unit Count: Fewer motor units were detected at C2 (n=16) compared to C5 (n=92), aligning with the higher recruitment threshold at C2.
  • Synchronization: Motor unit pairs within the same fascicle showed significantly higher synchronization (CIS = 0.47 ± 0.32) than pairs between different fascicles (CIS = 0.09 ± 0.07) (P < 0.05).
  • EMG Amplitude: Global EMG amplitude was significantly greater at C5 than at C2 during ramped contractions (0-50% MVC), consistent with the higher motor unit recruitment and activity in the lower fascicle.
  • Discharge Rate & Variability: No significant differences were found in motor unit discharge rate or interspike interval variability between the C2 and C5 levels.

Limitations and Future Work

  • Single-Site Detection: A key limitation acknowledged by the authors is that motor units were detected from only a single location within each spinal level. This could introduce errors in estimating synchronization strength within fascicles. Future work could involve multi-site recordings within fascicles to improve accuracy.
  • Difficulty in Insertion: The authors note the technical challenges of precise electrode insertion due to the complex anatomy and proximity of other muscles and blood vessels.
  • Future Directions: The study suggests that the observed non-uniform synaptic input and preferential recruitment of caudal fascicles are likely driven by the biomechanical demands of the cervical spine. Further research could explore how these patterns adapt during different tasks (e.g., flexion, rotation) and in individuals with neck pain or injuries. Investigating the underlying neural pathways responsible for this differential input would also be a valuable next step.

Summary updated

Abstract

This study investigated the behavior of motor units in the semispinalis cervicis muscle. Intramuscular EMG recordings were obtained unilaterally at levels C2 and C5 in 15 healthy volunteers (8 men, 7 women) who performed isometric neck extensions at 5%, 10%, and 20% of the maximal force [maximum voluntary contraction (MVC)] for 2 min each and linearly increasing force contractions from 0 to 30% MVC over 3 s. Individual motor unit action potentials were identified. The discharge rate and interspike interval variability of the motor units in the two locations did not differ. However, the recruitment threshold of motor units detected at C2 (n = 16, mean ± SD: 10.3 ± 6.0% MVC) was greater than that of motor units detected at C5 (n = 92, 6.9 ± 4.3% MVC) (P < 0.01). A significant level of short-term synchronization was identified in 246 of 307 motor unit pairs when computed within one spinal level but only in 28 of 110 pairs of motor units between the two levels. The common input strength, which quantifies motor unit synchronization, was greater for pairs within one level (0.47 ± 0.32) compared with pairs between levels (0.09 ± 0.07) (P < 0.05). In a second experiment on eight healthy subjects, interference EMG was recorded from the same locations during a linearly increasing force contraction from 0 to 40% MVC and showed significantly greater EMG amplitude at C5 than at C2. In conclusion, synaptic input is distributed partly independently and nonuniformly to different fascicles of the semispinalis cervicis muscle.
BibTeX
@article{schomacher2012recruitment,
  author = {Jochen Schomacher and Jakob Lund Dideriksen and Dario Farina and Deborah Falla},
  title = {{Recruitment of motor units in two fascicles of the semispinalis cervicis muscle}},
  journal = {Journal of Neurophysiology},
  year = {2012},
  doi = {10.1152/jn.00953.2011},
}
Figure