Abstract
The dorsal root ganglia (DRG) contain cell bodies of primary afferent neurons, which are frequently studied by recording extracellularly with penetrating microelectrodes inserted into the DRG. We aimed to isolate single- and multi-unit activity from primary afferents in the lumbar DRG using non-penetrating electrode arrays and to characterize the relationship of that activity with limb position and movement. The left sixth and seventh lumbar DRG (L6-L7) were instrumented with penetrating and non-penetrating electrode arrays to record neural activity during passive hindlimb movement in 7 anesthetized cats. We found that the non-penetrating arrays could record both multi-unit and well-isolated single-unit activity from the surface of the DRG, although with smaller signal to noise ratios (SNRs) compared to penetrating electrodes. Across all recorded units, the median SNR was 1.1 for non-penetrating electrodes and 1.6 for penetrating electrodes. Although the non-penetrating arrays were not anchored to the DRG or surrounding tissues, the spike amplitudes did not change (<1% change from baseline spike amplitude) when the limb was moved passively over a limited range of motion (~20 degrees at the hip). Units of various sensory fiber types were recorded, with 20% of units identified as primary muscle spindles, 37% as secondary muscle spindles, and 24% as cutaneous afferents. Our study suggests that non-penetrating electrode arrays can record modulated single- and multi-unit neural activity of various sensory fiber types from the DRG surface.
Introduction
Restoring sensation or motor control via neuroprosthetics requires high-fidelity recording of sensory information. The dorsal root ganglion (DRG), housing the cell bodies of primary afferent neurons, is a primary target for such interfaces. Traditionally, recording from the DRG has relied on penetrating microelectrode arrays, such as the Utah Array. While effective, these "needle-style" electrodes impose a "biological tax," causing tissue trauma, inflammation, and chronic scarring (gliosis) that eventually degrades signal quality. Furthermore, the DRG's proximity to moving joints makes rigid penetrating needles susceptible to mechanical failure.
Interestingly, the DRG's anatomy differs from the cerebral cortex; its highest density of cell bodies is located near the outer surface. This unique structure suggests that non-penetrating, surface-based electrode arrays might capture high-quality neural data without the risks associated with tissue penetration.
Methods
In this study, seven anesthetized cats were instrumented at the lumbar DRG (L6-L7) with both penetrating and non-penetrating electrode arrays for comparison. The penetrating arrays consisted of standard Utah Electrode Arrays (UEA) with 1-mm shanks. The non-penetrating arrays included flexible surface designs: gold electrodes on polyimide (MCS) and platinum electrodes on silicone (PMT).
Neural activity was recorded while a robotic arm moved the cats' hindlimbs through controlled trajectories. To identify specific sensory fiber types, researchers administered succinylcholine (SCh), which selectively increases the firing rate of muscle spindles. This allowed for the categorization of units into primary muscle spindles (Group Ia), secondary spindles (Group II), or cutaneous (touch) afferents. Kinematic data were captured using a 3D motion tracking system to correlate limb movement with neural firing.
Results
The study successfully isolated 226 units from non-penetrating arrays and 311 from penetrating arrays. While the median Signal-to-Noise Ratio (SNR) for surface electrodes (1.1) was lower than that of penetrating electrodes (1.6), it remained sufficient for isolating single-neuron activity. Notably, both electrode types yielded a similar number of units per electrode (~1.2).
A key finding was the remarkable stability of the surface recordings. Despite the arrays not being sutured or glued to the tissue, spike amplitudes changed by less than 1% during limb movement within a 20-degree range of motion. This suggests that the DRG’s natural environment may provide inherent stability for surface arrays.
Surface-recorded units exhibited longer "wavelengths" (wider spike shapes) compared to penetrating recordings. This phenomenon suggests that the epineurium—the tough outer sheath of the nerve—acts as a low-pass filter, smoothing the electrical signal as it passes to the surface. Despite this filtering, the arrays distinguished various sensory fiber types: 20% were primary muscle spindles, 37% were secondary spindles, and 24% were cutaneous afferents.
Discussion
This research demonstrates that non-penetrating electrode arrays can record high-fidelity, single-unit activity from the DRG surface. The stability of these recordings during movement, combined with the reduced risk of tissue damage, makes surface arrays a promising alternative for chronic sensory interfaces.
However, several challenges remain. This acute study was conducted under anesthesia; in freely moving subjects, mechanical stresses would be significantly higher, potentially requiring biocompatible adhesives for long-term stability. Additionally, the human epineurium is thicker than that of cats, which may further attenuate signals. Future developments in "open mesh" electrode designs and improved surgical fixation will be critical for translating these findings into durable, long-term neuroprosthetic applications.