NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Real-time digital trigger system for GTAF-II at CSNS Back-n white neutron source

Linhai Xie, Ping Cao, Tao Yu, Xinyi Tang, Zouyi Jiang, Qi An, Xiru Huang, C. Li, Jun Li, M. H. Gu, Q. Zhang, Guangyuan Luan, Xichao Ruan, Guangzhi He, Jie Ren, Jiaojiao Bai, Jie Bao, Yuhai Bao, H. Chen, Qiyin Chen, Y. Chen, Z. Chen, Z. Q. Cui, Ruirui Fan, C. Q. Feng, Kailun Gao, Xiaolong Gao, Chengcheng Han, Zishuo Han, Yuefeng He, Hong Yang, Yiwei Hu, Han‐Xiong Huang, Hao Jiang, Wei Jiang, Hantao Jing, Ling Kang, B. Li, Q. Li, Xin Li, Y. Li, Junfeng Liu, Rongzhen Liu, S. Liu, X. Liu, Zheng‐Wen Long, Changjun Ning, Ming Niu, Binbin Qi, Zhizhou Ren, Zhendi Song, Kang Sun, Zhiwei Sun, Zhixin Tan, Jingyu Tang, Bowei Tian, L. Wang, P. Wang, Zijing Wang, Z. Wen, Xuan Wu, Xiaoyun Yang, Yang Yi, Yi Han, Lei Yu, Yaxin Yu, G. Zhang, Li Zhang, X. Zhang, Y. Zhang, Zhiwei Zhang, Liang Zhou, Zhihao Zhou, Kejun ZhuJournal of Instrumentation 2021

Abstract

A 4-π detector array composed of 40 BaF_2 crystals named Gamma Total Absorption Facility II (GTAF-II) is designed for neutron capture cross-section (n, γ) measurements at Back-n white neutron source in China Spallation Neutron Source. The waveform digitizing (WFD) method is used to acquire the detector signals from GTAF-II accurately. To reduce the high data rate caused by the WFD method, a real-time digital trigger system is proposed in this paper. The trigger system is divided into local and global trigger processing to distinguish desired signals from various noises. The local trigger processing rejects photomultiplier noises and α particles by signal characteristics. The global trigger verification eliminates natural γ-rays according to the (n, γ) reaction mechanism. In order to realize the interaction between the local and global trigger processing, a high-precision global synchronization and trigger exchange network is constructed. Experiments with beams at back-n show that the trigger system provides a high data reduction factor. This trigger system covers the entire neutron energy range of 25 ms without dead time, and desired signals are acquired with full waveforms.
BibTeX
@article{xie2021real,
  author = {Linhai Xie and Ping Cao and Tao Yu and Xinyi Tang and Zouyi Jiang and Qi An and Xiru Huang and C. Li and Jun Li and M. H. Gu and Q. Zhang and Guangyuan Luan and Xichao Ruan and Guangzhi He and Jie Ren and Jiaojiao Bai and Jie Bao and Yuhai Bao and H. Chen and Qiyin Chen and Y. Chen and Z. Chen and Z. Q. Cui and Ruirui Fan and C. Q. Feng and Kailun Gao and Xiaolong Gao and Chengcheng Han and Zishuo Han and Yuefeng He and Hong Yang and Yiwei Hu and Han‐Xiong Huang and Hao Jiang and Wei Jiang and Hantao Jing and Ling Kang and B. Li and Q. Li and Xin Li and Y. Li and Junfeng Liu and Rongzhen Liu and S. Liu and X. Liu and Zheng‐Wen Long and Changjun Ning and Ming Niu and Binbin Qi and Zhizhou Ren and Zhendi Song and Kang Sun and Zhiwei Sun and Zhixin Tan and Jingyu Tang and Bowei Tian and L. Wang and P. Wang and Zijing Wang and Z. Wen and Xuan Wu and Xuan Wu and Xiaoyun Yang and Yang Yi and Yi Han and Lei Yu and Yaxin Yu and G. Zhang and Li Zhang and X. Zhang and Y. Zhang and Zhiwei Zhang and Liang Zhou and Zhihao Zhou and Kejun Zhu},
  title = {{Real-time digital trigger system for GTAF-II at CSNS Back-n white neutron source}},
  journal = {Journal of Instrumentation},
  year = {2021},
  doi = {10.1088/1748-0221/16/10/p10029},
}

Loading related content...