Radiographic and clinical outcomes of traumatic subtrochanteric femur fracture fixation and reduction methods

Micaela White, Rebeka Dejenie, Shannon Tse, Benjamin Brooks, Michelle Scott, GilbertoF. Chavez, Lydia J. McKeithan, Aziz Saade, Samuel K. Simister, Sean T. Campbell, Gillian Soles, Ellen Fitzpatrick, Mark Lee, Augustine M. SaizEuropean 2025

TL;DR

This retrospective study compares open versus closed reduction methods and various hardware implants for fixing subtrochanteric femur fractures. While open reduction provides superior anatomical alignment on X-rays, closed/percutaneous methods significantly reduce surgery time and blood loss without compromising long-term healing or patient mobility.

What Problem Does This Paper Address?

Subtrochanteric femur fractures—breaks occurring within 5 cm of the lesser trochanter—are notoriously difficult to treat. They are subject to intense biomechanical forces and are often the result of high-energy trauma in young patients or low-energy falls in the elderly.

Orthopedic surgeons face a classic dilemma:

  1. Open Reduction: Making a larger incision to manually realign the bone. This allows for "perfect" anatomical alignment but risks disrupting the blood supply and increasing surgical trauma.
  2. Closed/Percutaneous Reduction: Realigning the bone using external manipulation or small "stab" incisions. This is "biologically friendly" but often results in less precise alignment on post-operative radiographs.

The authors sought to determine if these differences in surgical approach and implant choice (nails vs. plates) actually translate to differences in how well a patient heals and walks.

Methods

The researchers conducted a retrospective cohort study at a Level-1 trauma center, reviewing 64 patients (65 fractures) treated between 2016 and 2023.

Key metrics included:

  • Radiographic Analysis: Measuring the femoral neck-shaft angle and maximum cortical displacement (how "off" the bone ends are) on X-rays.
  • mRUST Score: They used the modified Radiographic Union Scale for Tibia, adapted for the femur, to quantify bone healing over time (6 weeks to 1 year).
  • Clinical Outcomes: Tracking surgery duration, estimated blood loss (EBL), hardware failure, revision rates, and the patient's ability to walk independently.

The study compared three hardware configurations: Intramedullary Nails (IMN), plates, and Nail-Plate Combinations (NPC).

Datasets

The study utilized a primary clinical dataset of patient records and radiographs from a single Level-1 trauma center. No external or public benchmarks were used, as this is a clinical outcome study rather than a machine learning or algorithmic paper.

Key Insights and Ideas

  • The Precision vs. Efficiency Trade-off: The study confirmed that open reduction is the "gold standard" for visual alignment, significantly reducing sagittal displacement compared to closed methods. However, this precision comes at the cost of longer operating room times and higher blood loss.
  • Radiographic "Imperfection" vs. Clinical Success: Perhaps the most important takeaway is that "perfect" X-rays aren't everything. Even though closed reductions resulted in more cortical displacement on lateral imaging, there were no significant differences in union rates (mRUST scores), pain levels, or the ability to walk at the final follow-up.
  • BMI and Implant Choice: Surgeons were more likely to choose Intramedullary Nails (IMN) for patients with a higher Body Mass Index (BMI), likely because nails are load-sharing devices that can better handle the stresses in heavier patients compared to load-bearing plates.
  • The "Biological" Advantage: The study supports the idea that preserving the "fracture hematoma" (the blood environment around the break) via closed methods is viable, as healing rates were high regardless of the initial alignment precision.

Key Results

  • Surgical Efficiency: Closed/percutaneous reductions had significantly shorter surgery durations ($p=0.028$) and decreased estimated blood loss ($p=0.049$).
  • Alignment: Open reduction resulted in a mean lateral cortical displacement of 3.10 mm, compared to 6.36 mm for closed reductions ($p=0.025$).
  • Hardware Impact: IMN fixation showed increased displacement on lateral imaging compared to plates or combination fixations ($p=0.041$).
  • Healing: At the average follow-up of 132 days, there were no statistical differences in mRUST scores, hardware failure, or revision surgery rates between any of the groups.

Limitations and Future Work

The authors acknowledge several limitations:

  • Retrospective Design: The study looks backward at existing data, which can introduce selection bias (e.g., surgeons might choose open reduction for more "difficult" fractures).
  • Sample Size: With only 64 patients, the study may be underpowered to detect rare complications or subtle differences between plates and nail-plate combinations.
  • Follow-up Duration: The average follow-up was relatively short (132 days). While this captures early healing, it may miss very late-term hardware issues.

Future Work: The authors suggest that prospective, randomized controlled trials are needed to definitively compare these methods without the bias inherent in retrospective reviews. Additionally, longer-term follow-up would help clarify if the slight radiographic displacements seen in closed reductions lead to issues like post-traumatic arthritis years down the line.

Summary updated

Abstract

Subtrochanteric fractures treated with open reduction and presence of a plate in the fixation can improve sagittal alignment. Closed/percutaneous reduction decreases surgery duration and estimated blood loss. Regardless of reduction type and implant, adequate reduction, high union rates and successful outcomes are possible. Anatomic reduction and stable fixation are essential in surgical treatment, regardless of approach or implant choice.
BibTeX
@inproceedings{white2025radiographic,
  author = {Micaela White and Rebeka Dejenie and Shannon Tse and Benjamin Brooks and Michelle Scott and GilbertoF. Chavez and Lydia J. McKeithan and Aziz Saade and Samuel K. Simister and Sean T. Campbell and Gillian Soles and Ellen Fitzpatrick and Mark Lee and Augustine M. Saiz},
  title = {{Radiographic and clinical outcomes of traumatic subtrochanteric femur fracture fixation and reduction methods}},
  booktitle = {European},
  year = {2025},
  doi = {10.1007/s00590-025-04478-z},
}
Figure