TL;DR

Deep learning can reconstruct crisp medical and scientific images from noisy, incomplete data, but it sometimes hallucinates realistic-looking details that aren't actually there. QUTCC (pronounced cutesy) gives these reconstructions tight, statistically guaranteed pixel-by-pixel "error bars" in just two forward passes. By teaching a neural network to understand the entire probability landscape of an image rather than just a single guess, QUTCC flags potential hallucinations without the massive compute overhead of traditional uncertainty methods.

What Problem Does This Paper Address?

Imagine an AI reconstructing an MRI scan from a fraction of the usual sensor data. The output looks sharp, fast, and convincing—until it subtly invents a tear in a ligament or erases a tumor. When solving these imaging inverse problems (recovering a clean image $x$ from a degraded measurement $y$), doctors and scientists desperately need to know: where might this model be lying to me?

Enter conformal prediction, a mathematical framework that wraps a model's output in statistically valid uncertainty intervals (e.g., "we are 90% sure the true pixel value lies between $A$ and $B$") using a held-out calibration dataset.

However, existing conformal methods for images have a spatial blindness problem. Standard approaches (like Im2Im) calibrate uncertainty by multiplying every pixel's initial error bar by a single, global constant $\hat{\lambda}$. Slightly more advanced methods (like K-RCPS) chop the image into a few fixed, pre-computed regions and scale each one separately. Because neither approach adapts continuously to the actual features inside a specific image, they have to inflate uncertainty intervals everywhere just to cover the trickiest, noisiest regions—leaving you with overly wide, pessimistic error bars.

Methods

Instead of training a network to output a fixed pair of upper and lower bounds and stretching them with a blunt scalar multiplier, QUTCC embeds the uncertainty knob directly inside the neural network.

Overview of the QUTCC pipeline
  1. Simultaneous Quantile Regression (What's New): Using a standard Attention U-Net backbone, the authors inject a continuous quantile embedding $q \in (0,1)$. During training, $q$ is randomly sampled at each step and fed into both the network and an asymmetric pinball loss function (which penalizes under- or over-estimation depending on $q$). Instead of just learning the average image, a single network $f_\theta(y, q)$ learns the entire conditional quantile distribution. Querying $q = 0.5$ gives the median image reconstruction.
  2. Spatially-Adaptive Conformal Calibration: To guarantee 90% coverage ($\alpha = 0.1$), QUTCC doesn't scale the output pixels linearly. Instead, it runs a binary search on a calibration dataset to tune the input conditioning parameters ($\hat{q}_{\text{lo}}, \hat{q}_{\text{hi}}$)—say, shifting them from $(0.05, 0.95)$ to $(0.06, 0.97)$. Because these scalars pass through a deep, non-linear U-Net, tweaking two numbers at the input produces a continuous, content-aware, pixel-wise scaling across the output image.
QUTCC's implicit pixel-wise scaling adapts to anatomical structures
  1. Distribution-Free PDF Estimation: Because probability density is the inverse derivative of the quantile function, QUTCC can reconstruct the full pixel-wise probability density function (PDF) $p(x|y)$—with zero Gaussian assumptions—simply by querying the network at multiple calibrated quantiles and taking finite differences.

Datasets

No new benchmarks were introduced; QUTCC was evaluated across five imaging inverse tasks ( plus a toy MNIST compressive sensing setup with an exact closed-form Gaussian posterior):

  • Accelerated MRI (fastMRI dataset, tested across $4\times$ to $16\times$ undersampling accelerations).
  • Quantitative Phase Imaging (QPI) microscopy.
  • Microscopy Denoising under three regimes: real-world fluorescence microscopy noise, synthetic Poisson noise, and synthetic Gaussian noise.

Key Insights and Ideas

  • Heteroscedasticity is where QUTCC shines: When noise is uniform everywhere (like additive Gaussian noise), a single global scalar is already near-optimal. When uncertainty depends heavily on the signal itself—like Poisson noise, where brighter regions have higher variance, or highly ill-conditioned $16\times$ MRI—global scalars wastefully bloat intervals in easy regions. QUTCC adapts locally, yielding much tighter bounds in bright, signal-rich structures.
  • Catching hallucinations in the wild: On undersampled MRI scans, both baseline models and QUTCC occasionally hallucinated anatomical features absent from the ground truth. QUTCC's high-uncertainty heatmaps tightly co-located with these exact hallucinated structures.
  • Seeing skew without assuming it: By sweeping $q$, QUTCC's estimated pixel PDFs naturally recovered symmetric curves under Gaussian noise and distinctly skewed curves under Poisson noise—whereas ensemble baselines produced choppy, low-resolution distributions constrained by the number of trained models.

Key Results

All methods were calibrated to a 90% target coverage ($\alpha = 0.1$):

  • Tighter Conformal Bounds: QUTCC achieved the smallest mean uncertainty interval length across every task compared to conformal baselines (Im2Im, Im2Im-Asymmetric, and K-RCPS). Under high-intensity Poisson noise (pixel intensity $0.80\text{–}1.00$), QUTCC shrank interval width to $0.187$, compared to $0.302$ for Im2Im and $0.225$ for K-RCPS.
  • Ill-Conditioned Scaling: As MRI acceleration became harder (from $4\times$ to $16\times$), QUTCC's interval-tightness advantage over Im2Im grew more than sixfold (from $0.45\%$ to $2.78\%$).
  • Massive Compute Savings: Posterior-sampling baselines (MC-Dropout and Deep Ensembles) occasionally edged out QUTCC in raw interval width, but lacked formal guarantees and cost vastly more compute: MC-Dropout was $28\times\text{–}47\times$ slower at inference, and Deep Ensembles required $\sim 10\times$ more training time. QUTCC needs just one model and two forward passes for interval prediction.
  • Accurate Posteriors: On the closed-form MNIST task, QUTCC beat a 100-member Deep Ensemble and MC-Dropout in matching the true posterior (KL divergence of $0.293$ vs. $0.307$ and $6.928$).

Limitations and Future Work

  • Paired Data Requirement: QUTCC requires matched ground-truth/measurement pairs for both training and calibration, which can be scarce in scientific imaging (the authors point to emerging self-supervised conformal methods as a path forward).
  • Pixel-Marginal Guarantees Only: Like prior conformal image methods, coverage is guaranteed on average across pixels, not jointly across entire spatial structures—meaning rare events or out-of-distribution inputs could still slip through with false confidence.
  • Monotonicity & Numerical Sensitivity: Binary search assumes the learned quantile function increases monotonically (mostly true in practice, with rare violations in dark background pixels), and reconstructing full PDFs requires multiple forward passes and finite-difference differentiation, which is sensitive to quantile grid spacing.

Summary updated

Abstract

While deep learning offers tremendous promise for scientific and medical imaging, any failures and hallucinations (predictions that do not coincide with reality) are hard to pinpoint and can have serious downstream consequences. Uncertainty estimation techniques, such as conformal prediction, can help by predicting statistically valid error bars for a model's prediction. However, popular conformal prediction methods were not designed for high-dimensional image-valued problems and do not take into account spatial correlations within an image during conformal calibration, resulting in larger-than-necessary uncertainty intervals. We propose a practical simultaneous quantile regression method that enables non-linear, spatially-adaptive scaling during conformal calibration. Our method, QUTCC uses a U-Net architecture with a quantile embedding to learn a full conditional quantile distribution during training, and then leverages this non-linear, learned function for spatially-adaptive conformal calibration. At test time, our method can efficiently estimate uncertainty intervals with pixel-marginal coverage guarantees. In addition, QUTCC can also predict pixel-wise conditional probability density estimates without any built-in distributional assumptions. We evaluate our method on several denoising problems, accelerated magnetic resonance imaging, and quantitative phase microscopy. Our method consistently produces tighter uncertainty intervals than prior conformal methods at the same coverage level, can predict plausible conditional distributions for different tasks, and in some cases, high-uncertainty regions can help us locate hallucinations in a model's prediction.
BibTeX
@inproceedings{ye2026qutcc,
  author = {Cassandra Tong Ye and Shamus Li and Tyler King and Kristina Monakhova},
  title = {{QUTCC: Quantile Uncertainty Training and Conformal Calibration for Imaging Inverse Problems}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=hIqpI82zrU},
}
Figure