Qubit noise spectroscopy using a continuous driving field

Daniel K. Park, Jonathan BaugharXiv 2013 · DOI

TL;DR

This paper introduces and validates a continuous-wave (CW) driving field method for qubit noise spectroscopy, offering a simpler and potentially more robust alternative to existing pulsed techniques. The study rigorously analyzes the CW method using theoretical frameworks and confirms its accuracy with a solid-state NMR experiment, demonstrating its capability to characterize noise spectra.

What Problem Does This Paper Address?

Quantum error correction and dynamical decoupling schemes are crucial for building reliable quantum computers. However, their effectiveness hinges on a precise understanding of the noise environment affecting qubits. While pulsed dynamical decoupling sequences have been widely used for noise spectroscopy, they can be complex to implement and sensitive to experimental imperfections. This paper addresses the need for simpler, more robust methods for characterizing qubit noise, specifically focusing on single-axis noise, by exploring the use of a continuous-wave (CW) driving field.

Methods

The authors investigate noise spectroscopy using a continuous-wave (CW) on-resonance driving field, a technique analogous to spin-locking in NMR. They compare three theoretical approaches:

  • Heuristic Filter Function: A simplified model that provides a qualitatively correct but quantitatively inaccurate result.
  • Generalized Bloch Equations (GBE): A more rigorous theoretical framework for describing the dynamics of a system interacting with a bath and a driving field.
  • Average Hamiltonian Theory (AHT): A method used to derive an effective time-independent Hamiltonian from a time-dependent one. The paper calculates AHT up to second order.

These theoretical models are then compared to experimental results from a solid-state nuclear magnetic resonance (NMR) experiment.

Datasets

Not discussed in the paper. The experiment uses a naturally abundant ¹³C nucleus in single crystal malonic acid as the qubit, coupled to a ¹H spin bath.

Key Insights and Ideas

  • CW Spectroscopy as a Viable Alternative: The CW approach, while seemingly simpler, can provide reliable noise spectroscopy, comparable to pulsed methods, under specific conditions.
  • Theoretical Consistency: The 0th-order AHT calculation aligns with the GBE predictions, validating the theoretical framework for CW noise spectroscopy.
  • Higher-Order Corrections: Second-order AHT corrections reveal a slight deviation from simple exponential decay, suggesting that for highly precise measurements, these higher-order effects might need to be considered.
  • Experimental Validation: The NMR experiment confirms that CW and pulsed noise spectroscopy methods yield consistent results, strengthening the credibility of the CW approach.
  • Noise Characterization: The study demonstrates that the noise in their experimental system follows a power law decay of approximately $w^{-1}$, a common characteristic of many physical noise sources.

Key Results

  • The 0th-order average Hamiltonian theory accurately predicts the coherence decay rate, matching the generalized Bloch equations.
  • Second-order AHT corrections provide a few-percent correction to the decay, introducing a slight Gaussian component.
  • A solid-state NMR experiment showed agreement between CW and pulsed noise spectroscopy methods within experimental error.
  • The noise spectrum was found to follow a power law decay of approximately $w^{-0.9 \pm 0.1}$ for CPMG (pulsed) and $w^{-0.8 \pm 0.1}$ for CW methods.

Limitations and Future Work

  • Markovian Assumption: The GBE approach relies on the Markovian approximation for the noise, which may not hold for all noise sources. The proton spin bath used in the experiment is noted as not strictly Markovian.
  • Signal-to-Noise Ratio: The NMR experiment had a limited signal-to-noise ratio, leading to larger error bars in the CW data. More precise measurements would require systems with higher signal-to-noise.
  • Higher-Order AHT: While the paper estimates second-order AHT corrections, exact analytical calculation of higher-order terms is challenging.
  • Future Directions: The authors suggest extending these noise spectroscopy methods to more general types of noise, including non-Markovian environments, and testing them in systems that better approximate Markovian behavior. They also propose investigating whether deviations from simple exponential decay due to higher-order AHT terms can be observed in future experiments.

Summary updated

Abstract

The optimization of dynamical decoupling and quantum error correction for a particular qubit realization is based on a detailed knowledge of the noise properties. Spectroscopy of single-axis noise using dynamical decoupling pulse sequences has garnered much recent attention. Here we consider noise spectroscopy based on a spin-locking type pulse sequence, i.e. a continuous-wave (CW) on-resonance driving field. We show that a heuristic filter function approach produces a qualitatively correct (but quantitatively incorrect) result, whereas a 0th-order average Hamiltonian calculation is shown to agree with the result predicted by the generalized Bloch equations. We further calculate up to 2nd-order average Hamiltonian corrections and show the deviation from the generalized Bloch equation result. This shows that noise spectroscopy using continuous fields, in some cases simpler to implement and more robust to errors than pulsed schemes, can be rigorously analyzed and criteria for reliable measurements can be established. Finally, a solid-state nuclear magnetic resonance experiment is presented which demonstrates that the CW and pulsed methods agree within experimental error. The noise, due to magnetization fluctuations in a dipolar coupled proton spin bath, is found to obey a roughly 1/ω power law decay in the range of frequencies ω investigated.
BibTeX
@misc{park2013qubit,
  author = {Daniel K. Park and Jonathan Baugh},
  title = {{Qubit noise spectroscopy using a continuous driving field}},
  year = {2013},
  eprint = {1308.6310},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/1308.6310},
}

Loading related content...

Figure