Quantifying errors in the aerosol mixing-state index based on limited particle sample size
Abstract
This study evaluates the error that is introduced in quantifying observed aerosol mixing states due to a limited particle sample size. We used the particle-resolved model PartMC-MOSAIC to generate a scenario library that encompasses a large number of reference particle populations with a wide range of mixing states quantified by the mixing-state index χ. We stochastically sub-sampled these particle populations using sample sizes of 10 to 10,000 particles and recalculated χ based on the sub-samples. The finite sample size led to a consistent overestimation of χ, with the 95% confidence intervals ranging from −70 to 30 percentage points for sample sizes of 10 particles, and decreasing to ±10 percentage points for sample sizes of 10,000 particles. These findings were experimentally confirmed with single-particle measurements from the Pittsburgh area using a soot-particle aerosol mass spectrometer.Copyright © 2020 American Association for Aerosol Research
BibTeX
@inproceedings{gasparik2020quantifying,
author = {Jessica Gasparik and Qing Ye and Jeffrey H. Curtis and Albert A. Presto and Neil M. Donahue and Ryan C. Sullivan and Matthew West and Nicole Riemer},
title = {{Quantifying errors in the aerosol mixing-state index based on limited particle sample size}},
booktitle = {Aerosol},
year = {2020},
doi = {10.1080/02786826.2020.1804523},
}Ask Althea to put this paper to the test.