Quantification of Motion Reduction using Pre-simulation Assessment Sessions (PASS) for Stereotactic Ablative Body Radiotherapy (SABR)

Sophie Duncan, F. R. Hudson, Michaela Beavan, Mark Lee, Andrew Wallis, Sankar ArumugamJournal of Medical and Radiation Oncology 2024 · DOI

TL;DR

This paper validates the "PASS" (Pre-simulation Assessment Session) workflow, a proactive approach to selecting the best respiratory motion management strategy for radiotherapy patients. By testing techniques like breath-holding and abdominal compression before the final treatment planning stage, clinicians achieved significant motion reduction in 85% of patients, regardless of their age or BMI.

What Problem Does This Paper Address?

Stereotactic Ablative Body Radiotherapy (SABR) is a high-stakes procedure. It delivers potent, ablative doses of radiation to small tumors with surgical precision. However, tumors located in the liver, pancreas, or lower lungs are "moving targets" because they shift with every breath the patient takes.

To avoid damaging healthy tissue or under-dosing the tumor, clinicians use Motion Management Strategies (MMS). The two heavy hitters are Expiration Breath-Hold (EBH), where the patient holds their breath at a specific point, and Abdominal Compression (AC), which uses a belt to physically limit diaphragmatic excursion.

The challenge? Not every patient can hold their breath for 20 seconds, and not everyone finds a compression belt tolerable. Traditionally, these techniques might be decided during the CT simulation itself, leading to wasted time or suboptimal setups. This paper evaluates the PASS workflow—a dedicated "dry run" session to quantify which technique works best for a specific patient before the planning begins.

Methods

The researchers conducted a retrospective study of 73 patients treated between 2018 and 2022. The PASS workflow involves:

  1. Cine X-ray Imaging: Using fluoroscopy to watch the diaphragm move in real-time.
  2. Surrogate Tracking: Since tumors can be hard to see on X-rays, the apex of the diaphragm was used as a proxy for tumor motion.
  3. The "Try-Before-You-Buy" Approach: Patients were first assessed for EBH (the gold standard). If they couldn't meet the criteria (e.g., holding breath for 15+ seconds with reproducible diaphragm positioning), they were tested for AC.
  4. Quantification: Motion was measured across three cycles of Free Breathing (FB) and compared against the chosen MMS using the Wilcoxon Matched Pairs Test.

Datasets

The study utilized a retrospective clinical dataset from the Liverpool and Macarthur Cancer Therapy Centres in Australia. It included 73 patients with tumors in the liver (78.1%), pancreas (9.6%), adrenal glands (9.6%), and lungs (2.7%).

Key Insights and Ideas

  • High Success Rate: 85% of patients were successfully assigned an MMS that significantly reduced motion. This suggests that a structured pre-assessment is highly effective at filtering patients into the right treatment bucket.
  • EBH is King (If You Can Do It): EBH was far more effective than AC, reducing mean motion to a mere 2mm. However, it has stricter eligibility (no dentures, ability to follow English instructions, etc.).
  • Demographics Aren't Destiny: Surprisingly, the study found no association between a patient’s age or BMI and their ability to successfully use EBH or AC. This is a crucial "aha moment" for clinicians: you shouldn't assume an elderly or overweight patient won't be able to handle a breath-hold technique.
  • Clinical Realism: The study notes that even with a successful PASS, 12% of patients still faced minor issues during actual treatment (like needing a re-plan due to tissue changes), highlighting that motion management is an ongoing battle, not a one-time fix.

Key Results

  • EBH Performance: Reduced mean diaphragm motion from 20.9mm (Free Breathing) down to 2.0mm.
  • AC Performance: Reduced mean diaphragm motion from 17.7mm (Free Breathing) down to 8.4mm.
  • Statistical Significance: Both EBH and AC showed a statistically significant reduction in motion compared to free breathing (p < 0.05).
  • Patient Distribution: Of the 73 patients, 28 used EBH, 34 used AC, and 11 remained in Free Breathing (FB) because they were unsuitable for either intervention.

Limitations and Future Work

The primary limitation is the use of the diaphragm as a surrogate. While the diaphragm is a good proxy for superior-inferior (up and down) motion, it doesn't perfectly capture left-right or anterior-posterior shifts of the actual tumor. Furthermore, the PASS process adds time to the clinical workflow and requires extra staff training.

The authors suggest that future research should focus on the dosimetric impact: does this measured reduction in motion actually allow for smaller "safety margins" (ITVs) and, consequently, lower radiation doses to healthy organs? Proving that PASS leads to fewer side effects would be the final piece of the puzzle.

Summary updated

Abstract

Background:Pre-simulation Assessment Sessions (PASS) can be utilised to assess respiratory motion in patients receiving stereotactic ablative body radiotherapy (SABR). PASS is an assessment process that uses cine x-ray images to determine whether expiration breath-hold (EBH) or abdominal compression (AC) can be effectively utilised to manage diaphragm motion, prior to computed tomography (CT) simulation. This study aimed to determine the effectiveness of PASS for eligible patients based on diaphragm motion in free breathing (FB) compared to using MMSs. Material and Methods: Retrospective data on diaphragm motion in FB and elected MMS was collected for 73 patients. Eligible patients were treated between 2018-2022 using SABR for abdominal and lower lobe lung tumours. In the PASS process, the diaphragm motion seen on cine x-ray images was measured through three cycles of FB versus the elected MMS. Differences in FB and MMS diaphragm motion was found for each patient using Wilcoxon Matched Pairs Test. Results: Of the 73 patients, 28 were treated with EBH, 34 with AC, 2 with alternate strategies and 11 were treated using FB as they were not suitable for a MMS. There was a statistically significant difference between the mean of the amplitude of the diaphragm motion when comparing FB and EBH and FB and AC (p= 0.05). There were no associations found between the PASS success rate for any MMS and BMI or age. Conclusion: PASS is a useful tool which can be used to shape the future of radiotherapy by selecting the patient specific MMS for the reduction of tumour motion during SABR treatments. This study will be used to further investigate the dosimetric effects of MMS on internal margin reductions and normal tissue sparing.
BibTeX