NeurIPS 2026Coming to NeurIPS in Sydney?Explore papers, orals & directions

Quality-Control Policies Shape Model Behaviour in Computational Pathology

Mario Parreño Centeno, Yu Guan, Pedro Montero Pavón, Sanna Palosaari, Juha VäyrynenarXiv 2026

In the world of computational pathology, we often talk about "garbage in, garbage out." If you feed an AI model a digitized microscope slide full of blur, air bubbles, or pen marks, you can’t expect a perfect diagnosis. But here’s the catch: most researchers treat Quality Control (QC) as a "black box" preprocessing step—a hidden filter that just happens before the real work begins.

This paper argues that how you choose to filter your data is just as important as the model itself. By making these QC policies explicit and configurable, the authors show we can significantly boost model performance and make AI in medicine much more auditable.

TL;DR

The authors introduce TileNet, a framework that separates the act of detecting image defects from the policy of what to do with them. By treating quality control as a tunable dial rather than a fixed filter, they improved cancer detection performance (AUC) from 0.758 to 0.839 on a major benchmark and showed that "training on the trash"—using real artifacts for data augmentation—makes models significantly more robust.

What Problem Does This Paper Address?

Whole-slide images (WSIs) are the high-resolution "gigapixel" maps of pathology. However, they are messy. Between the biopsy needle and the digital scanner, slides pick up "nuisance variation": tissue folds, out-of-focus regions, and even the pathologist’s own pen marks.

Traditionally, researchers use simple heuristics (like "is this pixel dark enough to be tissue?") to decide which parts of a slide to show the AI. The problem is twofold:

  1. Coupling: The detector (finding the mess) and the policy (deciding to delete it) are usually stuck together. You can't easily test if a "strict" policy is better than a "relaxed" one.
  2. The "Adipose" Problem: Simple filters often mistake legitimate structures, like fat cells (adipose tissue), for empty background, accidentally throwing away the very data the model needs to learn.

Methods

The authors propose a "separation of concerns" through a framework called TileNet.

Instead of a single "keep/reject" step, TileNet works in two stages:

  1. Dense Estimation: A neural network (specifically a Swin-UPerNet) looks at the slide and creates a high-resolution map of three classes: Tissue, Background, and Artefact.
  2. Explicit Policy Layer: A user-defined rule then looks at these maps. For example, a policy might be: "Keep this tile only if it is at least 50% tissue and less than 1% artefact."
Fig. 1. Artefact-aware quality control as an explicit policy layer in computa- tional pathology. a, Overview of a tile-based computational pathology workflow. Technical variation may be introduced during tissue preparation, whole-slide image (WSI) preparation and digitisation. TileNet is inserted upstream of downstream image analysis as an artefact-aware quality-control framework that generates dense tissue/background/artefact maps and converts them into explicit tile-selection policies. b, Representative sources of technical artefacts and vari- ability across the histopathology workflow, including tissue collection, fixation, processing, embedding, sectioning, staining, mounting, coverslipping and slide scanning. c, TileNet execution pipeline. WSIs are partitioned into regions of interest (ROIs), processed by a dense QC predictor to generate three-class tis- sue/background/artefact outputs, and reconstructed into WSI-aligned QC maps. Tile-level tissue, background and artefact fractions are then aggregated over each tile footprint and converted into keep/reject decisions using user-defined policy thresholds.

They also introduced PathQCAug. Instead of just discarding tiles with artifacts, they extracted those real-world "defects" (like a tissue fold) and digitally pasted them onto clean images during training. This teaches the model to see through the noise rather than just being blinded by it.

Datasets

The study introduces a massive new resource called PathQC-3C:

  • Scale: 1,661 densely annotated regions from 1,194 whole-slide images.
  • Diversity: Covers 32 different cancer and tissue categories.
  • Granularity: Unlike previous datasets that might just label a whole patch as "bad," this provides pixel-level masks for what is tissue vs. what is a defect.

They also evaluated their methods on several "gold standard" public datasets, including TCGA (The Cancer Genome Atlas), CAMELYON16 (for lymph node metastasis), and BCSS (for breast cancer segmentation).

A comparison of PathQC-3C against other existing quality-control resources.

Key Insights and Ideas

  • Background is a "Nuisance": One of the biggest "aha" moments was that simply being smarter about excluding background (empty space) improved cancer classification performance more than almost anything else. In Multiple Instance Learning (MIL), background-aware selection jumped the AUC from 0.758 to 0.839.
  • The Policy Matters: There is no "universal" QC rule. A policy that works for finding a tumor might be too strict for a model trying to segment different types of cells. By separating the policy, researchers can finally "tune" their QC for the specific medical task at hand.
  • Pathologists vs. Models: In a blinded audit, the authors found that pathologists and AI models don't always agree on what makes a slide "unusable." A human might reject a slide because it looks "ugly," while the AI might still find it perfectly informative.
  • Real Noise > Synthetic Noise: Using real-world artifacts for data augmentation (PathQCAug) outperformed standard techniques like "random erasing." It turns out that teaching a model what a real tissue fold looks like is much more effective than just covering parts of the image with gray squares.

Key Results

  • Performance Boost: In the CAMELYON16 challenge, TileNet-guided selection improved the area under the curve (AUC) significantly compared to random sampling (0.839 vs 0.758).
  • Data Efficiency: In lung cancer classification, applying a strict artifact exclusion policy reduced the "candidate pool" of image tiles by 43%. This means the model could achieve similar results while processing nearly half as much data.
  • Robustness: Models trained with PathQCAug were significantly better at handling "messy" slides, maintaining high accuracy even when images were heavily corrupted by simulated artifacts.

Limitations and Future Work

While the paper makes a strong case for explicit QC, the authors note a few hurdles:

  • The "Catch-all" Class: The "Artefact" class currently lumps together very different things—a pen mark is not the same as a blur. Future work could benefit from more fine-grained categories.
  • Clinical Utility: While the models got better at the "math" of the task, the authors emphasize that we still need to prove this leads to better patient outcomes or faster lab turnaround times in a real hospital setting.
  • Computational Cost: Running a dense segmentation model just for quality control adds an extra layer of computation, which might be a bottleneck for some high-speed clinical workflows.

Summary updated

Abstract

Quality-control policies determine which image regions are used by computational pathology models, but their effects are difficult to isolate when quality estimation and input selection are coupled. We make these policies explicit, configurable and testable. We introduce PathQC-3C, comprising 1,661 densely annotated regions from 1,194 haematoxylin and eosin whole-slide images across 32 cancer/tissue categories, and TileNet, a framework that separates dense tissue/background/artefact estimation from task-specific input-selection policies. We evaluated the default predictor across three held-out cohorts and against harmonised quality-control comparators, assessed policy decisions in a blinded single-pathologist audit, and tested alternative policies in three downstream settings. In retrospective CAMELYON16 multiple-instance learning, background-aware selection improved the pooled out-of-fold area under the receiver operating characteristic curve from 0.758 to 0.839 compared with random sampling from the same exhaustive candidate pool under a fixed tile budget. In weak-label lung classification, strict artefact exclusion reduced the pre-matching candidate pool by approximately 43%, with small metric-dependent differences after matching training-set size and patient contribution. PathQCAug, which composites real artefact components during tumour-stroma model adaptation, improved macro Dice on high-artefact tiles under severe held-out composited artefacts across three training seeds and outperformed random-erasing and clean-tissue controls. Separating quality estimation from policy execution provides an auditable way to control which image content enters computational pathology models; the appropriate policy is task specific, and clinical utility remains to be established.
BibTeX
@misc{centeno2026quality,
  author = {Mario Parreño Centeno and Yu Guan and Pedro Montero Pavón and Sanna Palosaari and Juha Väyrynen},
  title = {{Quality-Control Policies Shape Model Behaviour in Computational Pathology}},
  year = {2026},
  eprint = {2611.28179},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.28179},
}
Figure