TL;DR
This paper introduces a novel simulation-based method for quality control (QC) of Distributed Acoustic Sensing (DAS) Vertical Seismic Profiling (VSP) data acquired in challenging desert environments. By simulating DAS VSP data using well logs and checkshot velocities, the authors demonstrate a high degree of similarity with field data, offering a robust QC tool that doesn't rely on potentially unreliable geophone data.
What Problem Does This Paper Address?
Acquiring high-quality seismic data in desert environments presents significant challenges. Extreme daily temperature fluctuations and complex near-surface geology can degrade the performance of seismic sensors, particularly Distributed Acoustic Sensing (DAS) systems used in Vertical Seismic Profiling (VSP). While geophones are often considered the "gold standard" for benchmarking DAS data, their own performance can be compromised in these conditions, leading to unreliable comparisons. Specifically, issues like channel depth uncertainty, measurement amplitude reliability, and noise characteristics can hinder the effective use of DAS VSP data. This paper addresses the need for a reliable QC method for DAS VSP data in desert settings, especially when geophone data is of poor quality or unavailable.
Methods
The core of this research lies in developing a simulation-based approach for DAS VSP data QC. The methodology involves:
- Depth Calibration: The study first addresses the critical issue of DAS channel depth uncertainty. They employ an amplitude-based method, referencing well logs and checkshot data, to calibrate the DAS channel depths to formation depths. This involves picking first breaks, flattening arrivals, calculating RMS amplitudes within a window around first breaks, and then using cross-correlation to find the optimal depth shift.
- Synthetic Data Generation: A 2D pseudo-spectral seismic modeling code is used to generate synthetic DAS VSP data. This simulation incorporates a 1D velocity model derived from checkshot data, and the acquisition parameters (channel spacing, gauge length) are matched to the field acquisition.
- Source and Receiver Signature Estimation: To ensure accurate comparison between synthetic and field data, the source signature is estimated using matching filters. This involves deconvolving field traces with synthetic traces. Similarly, the DAS instrument response (receiver signature) is estimated by deconvolving the field DAS wavefield with the synthetic DAS wavefield.
- Matching Filters and Deconvolution: Matching filters are a key tool used to align the synthetic and field data, particularly for estimating the source signature. Deconvolution is also employed to estimate the receiver signature.
- New QC Metric (PSNR): A novel quantitative QC metric, Peak Signal-to-Noise Ratio (PSNR) for receiver functions, is proposed. This metric helps identify noisy channels by measuring the signal power relative to the noise in a small time window.
Datasets
The study utilizes field DAS VSP data acquired from two adjacent non-flowing wells in a desert environment. These wells extend to approximately 4 km depth. Well-A has a DAS fiber optic cable installed, along with sonic log data. Well-B has DAS, geophone, and well log data. The geophone data from Well-B, however, is noted to have significant amplitude discrepancies due to poor coupling in two out of four receivers, rendering it unreliable for direct comparison. The study also uses well logs and checkshot data for depth calibration and velocity modeling.
Key Insights and Ideas
- Simulation as a Reliable QC Tool: The most significant insight is that simulated DAS VSP data can achieve high visual similarity with field DAS data, even in challenging desert environments. This validates the simulation approach as a robust QC tool, especially when geophone data is compromised.
- Geophone Data Unreliability in Deserts: The study highlights that geophone data quality can be severely impacted by desert conditions (e.g., poor coupling leading to amplitude variations), making it an unreliable "gold standard" in such scenarios.
- DAS Amplitude Robustness: DAS amplitudes are found to be more usable and robust than geophone amplitudes, likely due to the distributed nature of DAS sensors compared to the point-receiver nature of geophones.
- Depth Calibration is Crucial: The research emphasizes the importance of accurate depth calibration for DAS channels, as errors can significantly impact data interpretation. The proposed amplitude-based method provides a reliable way to achieve this.
- New QC Metric for Receiver Functions: The introduction of the PSNR metric for receiver functions offers a quantitative way to assess the quality of individual DAS channels, aiding in the identification and potential discarding of noisy channels.
Key Results
- Simulated DAS VSP data show high visual similarity with field DAS first arrival waveforms.
- The simulated source and receiver signatures are visually indistinguishable from the field DAS data.
- A bulk depth shift of -24 m was identified for DAS data, indicating the DAS channels are deeper than the well log depths by this amount.
- The geophone data exhibited high amplitude variations, making them unusable for direct comparison and simulation.
- The proposed simulation-based QC workflow can be used without geophone measurements.
- The PSNR metric, with a threshold of 15 dB, appears to be a reasonable choice for identifying noisy channels.
Limitations and Future Work
- 1D Velocity Model Limitation: The study acknowledges the simplicity of using a 1D velocity model for simulations, which restricts its applicability to areas with slowly varying lateral velocities. For areas with significant lateral variations, a 2D or 3D model would be necessary.
- Ambiguity in Advanced Model Building: Building more complex, laterally inhomogeneous models for simulation introduces ambiguity, as some noise in the data could be misinterpreted as lateral anomalies.
- Dispersion Factor: The varying nature of P-wave velocity dispersion is noted as a factor that can influence measurements.
- Future Work: The authors suggest further research into expanding the dataset and using more sophisticated deconvolution methods to refine the QC process. Finetuning the PSNR metric is also proposed as a subject for future investigation.
Summary updated