PULSE: Probabilistic Uncertainty-Aware Longitudinal Simulation for EHR Trajectories

Robert Lennart Manschke, Angus Roberts, Julia IveNeurIPS 2026

TL;DR

Predicting what happens next to a critically ill patient is notoriously hard because medical records are messy, sparsely sampled, and tangled up in doctors' real-time interventions. This paper introduces PULSE, a generative simulator for ICU patient trajectories that models not just expected vital signs, but the shape of clinical uncertainty as it unfolds hour by hour. By replacing static, generic noise with patient-specific probability distributions, PULSE brings us a step closer to reliable "digital twins" for testing medical policies before they ever touch a bedside.

What Problem Does This Paper Address?

Imagine trying to ask a counterfactual question in an Intensive Care Unit (ICU): "What would happen to this sepsis patient over the next 24 hours if we held off on vasopressors right now?"

In causal inference, answering this via observational Electronic Health Records (EHRs) often relies on g-computation—learning how patient states and treatments co-evolve, and then unrolling those learned dynamics forward under a hypothetical treatment rule.

However, ICU data fights back. Clinicians don’t measure lactate or blood pressure on a neat scientific metronome; the absence of a test is itself a clinical signal. Furthermore, patient physiology has weird, asymmetric uncertainty, and stays abruptly end via discharge or death. Previous state-of-the-art simulators (like G-Transformer) predict an average trajectory and slap static, empirical noise on top to generate rollouts. That approach misses a critical reality: a stable patient and a crashing patient do not share the same uncertainty profile.

Methods

PULSE is an autoregressive simulator family that generates patient trajectories one step at a time. It keeps the standard g-computation order of operations—predicting binary events (like ventilation, release, or death) before continuous vitals, while keeping treatment policies separate—but overhauls how states and uncertainties are parameterized:

Figure 1: PULSE-Spline rollout. Covariance-grouped encoders predict binary state and continuous distributions, which are sampled recursively. The central spline and its input and output densities use the first heart-rate forecast for a patient in the public MIMIC-IV demo database, conditional on a sampled binary state; intermediate densities illustrate the transition. Other distributions and trajectories show 100 paths generated for the same patient [Johnson et al., 2023a], with 16 paths displayed. Dots mark available measurements; input lines carry recorded values forward for display.
  • Covariance-Grouped Encoders: Instead of giving all 37 clinical variables their own isolated neural networks (expensive) or mushing them into one giant shared layer, PULSE clusters variables whose changes correlate in the training data (e.g., grouping blood gases together, labs together) into shared Transformer decoders.
  • Flexible Uncertainty via B-Spline Flows: Rather than assuming errors are simple bell curves or static residuals, PULSE-Spline passes a standard normal sample through a learned, monotone cubic B-spline transform. This acts as a lightweight normalizing flow, allowing the model to output skewed, heavy-tailed, patient-dependent probability distributions without expensive differential-equation integration.
  • Event-Time & Anchored Variants: Even on hourly-binned data, PULSE encodes continuous clock features, observation masks, and time-since-last-measurement so it doesn't confuse a carried-forward number with a fresh lab draw. Variants also test gated anchored residuals (explicitly gating how far a prediction drifts from the patient's last known value) and coupled group noise (PULSE-CovSpline).

Datasets

  • MIMIC-IV (v3.1): Primary evaluation on a Sepsis-3 cohort (8,934 subjects split into train/val/test), forecasting 37 continuous physiological variables and 7 binary states over 24 hours.
  • eICU: A multicenter ICU database used to test external validation and cross-hospital transfer on shared variable panels.
  • CVSim Benchmarks: Because real EHRs never show us the road not taken, the authors build three synthetic benchmarks using CVSim (a mechanistic cardiovascular simulator): clean, corrupted (adding EHR-like noise, irregular sampling, and confounding), and MIMIC-seeded (initializing synthetic patients from real MIMIC vitals to test counterfactual treatment escalation and withdrawal).

Key Insights and Ideas

  • Point error (RMSE) can be a mirage: One of the sharpest takeaways in the paper is that simply predicting the static training population average for every patient gets a surprisingly competitive Root Mean Squared Error (VRMSE of 6.533 at hour 2 vs. PULSE-Spline's 6.556)—despite being clinically useless and blind to treatments! Furthermore, adding realistic stochasticity can actually hurt traditional RMSE under certain scoring rules. Evaluating simulators requires proper probabilistic metrics like CRPS (Continuous Ranked Probability Score).
  • Life-and-death timing dominates trajectory error: Through oracle error decompositions, the authors reveal that a massive chunk of 24-hour physiological forecasting error actually stems from mistiming when a patient is discharged or dies (due to post-event padding in standard benchmarks).
  • Splines rival Continuous Normalizing Flows (CNFs) without the ODE tax: Direct monotone B-splines match continuous-time differential flows in distributional accuracy while remaining a clean, single-pass algebraic transformation.

Key Results

On the 37-variable MIMIC-IV predictive check (rolling out 100 Monte Carlo paths per patient from hour $k$ to hour 24):

Table 2: MIMIC predictive-check results. Point root mean squared error (RMSE) is computed after averaging Monte Carlo trajectories per patient. Each fitted model uses 100 paths and the shared treatment policy; scoring uses filled and post-event padded targets. Model and rollout settings are defined in Section 4.2; additional variants are in Sections A.4 and A.8. Model-minus-baseline differences are negative when the model improves on the baseline; intervals are 95% patient-bootstrap intervals, paired for differences. continuous ranked probability score (CRPS) scores distributions; Cov90 targets 0.90. Bold marks the best value and values whose paired 95% confidence interval for the difference from the best includes zero; these share first place in this comparison. Underlining marks the next-best tier using the same rule.
  • Forecasting from Hour 2 ($k=2$): PULSE-Spline achieves a VRMSE of 6.556 and CRPS of 0.4625, beating the G-Transformer reimplementation (VRMSE 6.845, CRPS 0.5191).
  • Forecasting from Hour 6 ($k=6$): With 5 hours of history, PULSE-Spline drops VRMSE to 5.805 and CRPS to 0.3930, outperforming G-Transformer (6.277 and 0.4725). PULSE-CNF scores nearly identically (VRMSE 5.767, CRPS 0.3923).
  • Synthetic Counterfactuals: On clean CVSim escalations, PULSE-Spline closely tracks ground-truth mechanistic treatment responses—for instance, predicting a +5.34 mmHg jump in mean arterial pressure versus the simulator's true +5.47 mmHg.

Limitations and Future Work

The authors are admirably candid about what remains unsolved. First, counterfactual validity on real patient data cannot be directly proven; while PULSE learns treatment effects in clean CVSim, those advantages become less stable when EHR-style corruption and confounding are injected, and individual responses remain somewhat attenuated in MIMIC-seeded transfer tests. Second, the model still operates on hourly-binned tables rather than raw, sub-hour bedside waveforms.

For future work, the authors advocate modeling ICU stay, discharge, and death as an explicit competing-risk survival process, separating treatment timing from dosage, and exploring state-space or LLM backbones equipped with clinical adapters.

Summary updated

Abstract

Realistic intensive-care electronic health record trajectories are difficult to simulate because physiology, treatments, observation times, and patient state co-evolve under sparse clinical measurement. We introduce PULSE, a probabilistic simulator family for intensive care trajectories. PULSE separates treatment from patient-state generation, predicts binary patient state before continuous physiology, and represents uncertainty with patient-dependent output distributions. Covariance groups assign variables to shared decoders, and a monotone B-spline flow models each continuous distribution. On a MIMIC-IV sepsis cohort scored over 37 variables, the B-spline model achieves vector-normalized root mean squared error of 6.556 and 5.805 when forecasting from hours two and six, compared with 6.845 and 6.277 for our G-Transformer reimplementation. Its continuous ranked probability score is 0.4625 and 0.3930, compared with 0.5191 and 0.4725 for that baseline. Paired patient-bootstrap intervals support improvements in both scores at both origins. A continuous normalizing flow achieves similar scores in the same evaluation. Cross-dataset experiments examine transfer to eICU. A controlled benchmark based on CVSim [Heldt et al., 2010] shows that a model can learn treatment responses under known synthetic dynamics.
BibTeX
@inproceedings{manschke2026pulse,
  author = {Robert Lennart Manschke and Angus Roberts and Julia Ive},
  title = {{PULSE: Probabilistic Uncertainty-Aware Longitudinal Simulation for EHR Trajectories}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=seIHyi0c7e},
}
Figure